In vitro comparison of epidural bacteria filters permeability and screening scanning electron microscopy

Background and objectives: Epidural catheter bacteria filters are barriers in the patient-controlled analgesia/anaesthesia for preventing contamination at the epidural insertion site. The efficiency of these filters varies according to pore sizes and materials. Method: The bacterial adhesion capabil...

Full description

Bibliographic Details
Main Authors: Aysin Sener, Yuksel Erkin, Alper Sener, Aydin Tasdogen, Esra Dokumaci, Zahide Elar
Format: Article
Language:English
Published: Elsevier 2015-11-01
Series:Brazilian Journal of Anesthesiology
Subjects:
Online Access:http://www.sciencedirect.com/science/article/pii/S0104001413001929
id doaj-2c1718d747524ce08ef42853b80e8c65
record_format Article
spelling doaj-2c1718d747524ce08ef42853b80e8c652020-11-25T01:34:27ZengElsevierBrazilian Journal of Anesthesiology0104-00142015-11-01656491496In vitro comparison of epidural bacteria filters permeability and screening scanning electron microscopyAysin Sener0Yuksel Erkin1Alper Sener2Aydin Tasdogen3Esra Dokumaci4Zahide Elar5Anesthesiology and Reanimation Department, Canakkale Goverment Hospital, Canakkale, TurkeyAnesthesiology and Reanimation Department, Dokuz Eylul University, Faculty of Medicine, Izmir, TurkeyInfectious Disease Department, Onsekiz Mart University, Faculty of Medicine, Canakkale, TurkeyAnesthesiology and Reanimation Department, Dokuz Eylul University, Faculty of Medicine, Izmir, TurkeyMetallurgy and Material Engineering Department, Dokuz Eylul University, Faculty of Engineering, Izmir, TurkeyAnesthesiology and Reanimation Department, Dokuz Eylul University, Faculty of Medicine, Izmir, TurkeyBackground and objectives: Epidural catheter bacteria filters are barriers in the patient-controlled analgesia/anaesthesia for preventing contamination at the epidural insertion site. The efficiency of these filters varies according to pore sizes and materials. Method: The bacterial adhesion capability of the two filters was measured in vitro experiment. Adhesion capacities for standard Staphylococcus aureus (ATCC 25923) and Pseudomonas aeruginosa (ATCC 27853) strains of the two different filters (Portex and Rusch) which have the same pore size were examined. Bacterial suspension of 0.5 Mc Farland was placed in the patient-controlled analgesia pump, was filtered at a speed of 5 mL/h. in continuous infusion for 48 h and accumulated in bottle. The two filters were compared with colony counts of bacteria in the filters and bottles. At the same time, the filters and adhered bacteria were monitored by scanning electron microscope. Results: Electron microscopic examination of filters showed that the Portex filter had a granular and the Rusch filter fibrillary structure. Colony counting from the catheter and bottle showed that both of the filters have significant bacterial adhesion capability (p < 0.001). After the bacteria suspension infusion, colony countings showed that the Portex filter was more efficient (p < 0.001). There was not any difference between S. aureus and P. aeruginosa bacteria adhesion. In the SEM monitoring after the infusion, it was physically shown that the bacteria were adhered efficiently by both of the filters. Conclusion: The granular structured filter was found statistically and significantly more successful than the fibrial. Although the pore sizes of the filters were same – of which structural differences shown by SEM were the same – it would not be right to attribute the changes in the efficiencies to only structural differences. Using microbiological and physical proofs with regard to efficiency at the same time has been another important aspect of this experiment.http://www.sciencedirect.com/science/article/pii/S0104001413001929Bacteria filterStaphylococcus aureusPseudomonas aeruginosaScanning electron microscope
collection DOAJ
language English
format Article
sources DOAJ
author Aysin Sener
Yuksel Erkin
Alper Sener
Aydin Tasdogen
Esra Dokumaci
Zahide Elar
spellingShingle Aysin Sener
Yuksel Erkin
Alper Sener
Aydin Tasdogen
Esra Dokumaci
Zahide Elar
In vitro comparison of epidural bacteria filters permeability and screening scanning electron microscopy
Brazilian Journal of Anesthesiology
Bacteria filter
Staphylococcus aureus
Pseudomonas aeruginosa
Scanning electron microscope
author_facet Aysin Sener
Yuksel Erkin
Alper Sener
Aydin Tasdogen
Esra Dokumaci
Zahide Elar
author_sort Aysin Sener
title In vitro comparison of epidural bacteria filters permeability and screening scanning electron microscopy
title_short In vitro comparison of epidural bacteria filters permeability and screening scanning electron microscopy
title_full In vitro comparison of epidural bacteria filters permeability and screening scanning electron microscopy
title_fullStr In vitro comparison of epidural bacteria filters permeability and screening scanning electron microscopy
title_full_unstemmed In vitro comparison of epidural bacteria filters permeability and screening scanning electron microscopy
title_sort in vitro comparison of epidural bacteria filters permeability and screening scanning electron microscopy
publisher Elsevier
series Brazilian Journal of Anesthesiology
issn 0104-0014
publishDate 2015-11-01
description Background and objectives: Epidural catheter bacteria filters are barriers in the patient-controlled analgesia/anaesthesia for preventing contamination at the epidural insertion site. The efficiency of these filters varies according to pore sizes and materials. Method: The bacterial adhesion capability of the two filters was measured in vitro experiment. Adhesion capacities for standard Staphylococcus aureus (ATCC 25923) and Pseudomonas aeruginosa (ATCC 27853) strains of the two different filters (Portex and Rusch) which have the same pore size were examined. Bacterial suspension of 0.5 Mc Farland was placed in the patient-controlled analgesia pump, was filtered at a speed of 5 mL/h. in continuous infusion for 48 h and accumulated in bottle. The two filters were compared with colony counts of bacteria in the filters and bottles. At the same time, the filters and adhered bacteria were monitored by scanning electron microscope. Results: Electron microscopic examination of filters showed that the Portex filter had a granular and the Rusch filter fibrillary structure. Colony counting from the catheter and bottle showed that both of the filters have significant bacterial adhesion capability (p < 0.001). After the bacteria suspension infusion, colony countings showed that the Portex filter was more efficient (p < 0.001). There was not any difference between S. aureus and P. aeruginosa bacteria adhesion. In the SEM monitoring after the infusion, it was physically shown that the bacteria were adhered efficiently by both of the filters. Conclusion: The granular structured filter was found statistically and significantly more successful than the fibrial. Although the pore sizes of the filters were same – of which structural differences shown by SEM were the same – it would not be right to attribute the changes in the efficiencies to only structural differences. Using microbiological and physical proofs with regard to efficiency at the same time has been another important aspect of this experiment.
topic Bacteria filter
Staphylococcus aureus
Pseudomonas aeruginosa
Scanning electron microscope
url http://www.sciencedirect.com/science/article/pii/S0104001413001929
work_keys_str_mv AT aysinsener invitrocomparisonofepiduralbacteriafilterspermeabilityandscreeningscanningelectronmicroscopy
AT yukselerkin invitrocomparisonofepiduralbacteriafilterspermeabilityandscreeningscanningelectronmicroscopy
AT alpersener invitrocomparisonofepiduralbacteriafilterspermeabilityandscreeningscanningelectronmicroscopy
AT aydintasdogen invitrocomparisonofepiduralbacteriafilterspermeabilityandscreeningscanningelectronmicroscopy
AT esradokumaci invitrocomparisonofepiduralbacteriafilterspermeabilityandscreeningscanningelectronmicroscopy
AT zahideelar invitrocomparisonofepiduralbacteriafilterspermeabilityandscreeningscanningelectronmicroscopy
_version_ 1725072022778675200