Verification of Methodology for Determination of Deposit Thickness on Heat Transfer Surface of Natural Gas Coolers

The paper describes briefly an original methodology for the determination of the deposit thickness on the inside heat transfer surface of natural gas cooler and a procedure of its verification at the cooler CH_R of the booster station KS01 in Velké Kapušany. The methodology is based on the measurem...

Full description

Bibliographic Details
Main Authors: Miroslav PŘÍHODA, Mária ČARNOGURSKÁ, Jiří MOLÍNEK, René PYSZKO
Format: Article
Language:English
Published: VSB-Technical University of Ostrava 2010-12-01
Series:Transactions of the VSB : Technical University of Ostrava
Online Access:http://transactions.fs.vsb.cz/2010-3/1827.pdf
Description
Summary:The paper describes briefly an original methodology for the determination of the deposit thickness on the inside heat transfer surface of natural gas cooler and a procedure of its verification at the cooler CH_R of the booster station KS01 in Velké Kapušany. The methodology is based on the measurement of the degree of the gas cooling. It has the universal validity and can be used to determine the thickness of the deposits of all types of coolers working on any booster station.