Experimental assessment of the state of the lining materials used in the rehabilitation of sewers in residential buildings

The global needs associated with aging sewers in infrastructures are immense; moreover, traditional renewal by replacement is very costly and not fast enough to meet the renewal needs. To keep up with the rate of deterioration, different rehabilitation technologies, such as the use of polymeric lini...

Full description

Bibliographic Details
Main Author: Parastou Kharazmi
Format: Article
Language:English
Published: Elsevier 2019-12-01
Series:Case Studies in Construction Materials
Online Access:http://www.sciencedirect.com/science/article/pii/S2214509519303936
id doaj-2bb7c35305d2428ab48c86310fa3e751
record_format Article
spelling doaj-2bb7c35305d2428ab48c86310fa3e7512020-11-25T01:15:26ZengElsevierCase Studies in Construction Materials2214-50952019-12-0111Experimental assessment of the state of the lining materials used in the rehabilitation of sewers in residential buildingsParastou Kharazmi0KTH Royal Institute of Technology, Brinellvägen 23, 114 28, Stockholm, SwedenThe global needs associated with aging sewers in infrastructures are immense; moreover, traditional renewal by replacement is very costly and not fast enough to meet the renewal needs. To keep up with the rate of deterioration, different rehabilitation technologies, such as the use of polymeric lining, have seen increasing use worldwide. Pipe lining is a solution to stabilize the deterioration of the host pipes in order to extend the service life of the piping system. However, the properties of polymeric materials may degrade over time; therefore, the long-term performance of these lined pipes is a frequently raised concern in the field. The aim of this study was to investigate the state of sewers that had been previously renewed, in order to gather information that facilitates an understanding of the changes in properties of the lining materials after installation. Moreover, to identify the general issues related to pipeline rehabilitation with polymeric systems. The samples investigated in this work had three different types of linings, service times ranging from one week to ten years, were installed by five separate installation companies and had been removed from residential buildings located in different parts of Sweden. The state of the polymeric lining and the relined samples were studied by means of tests including microscopy and visual inspection, as well as thermal analysis such as dynamic mechanical analysis (DMA) and differential scanning calorimetry (DSC), mechanical testing, such as tensile and flexural testing, and thickness measurements. Keywords: Rehabilitation, Pipe lining, Sewer, Cured in place pipe, Coating, Pipe renewalhttp://www.sciencedirect.com/science/article/pii/S2214509519303936
collection DOAJ
language English
format Article
sources DOAJ
author Parastou Kharazmi
spellingShingle Parastou Kharazmi
Experimental assessment of the state of the lining materials used in the rehabilitation of sewers in residential buildings
Case Studies in Construction Materials
author_facet Parastou Kharazmi
author_sort Parastou Kharazmi
title Experimental assessment of the state of the lining materials used in the rehabilitation of sewers in residential buildings
title_short Experimental assessment of the state of the lining materials used in the rehabilitation of sewers in residential buildings
title_full Experimental assessment of the state of the lining materials used in the rehabilitation of sewers in residential buildings
title_fullStr Experimental assessment of the state of the lining materials used in the rehabilitation of sewers in residential buildings
title_full_unstemmed Experimental assessment of the state of the lining materials used in the rehabilitation of sewers in residential buildings
title_sort experimental assessment of the state of the lining materials used in the rehabilitation of sewers in residential buildings
publisher Elsevier
series Case Studies in Construction Materials
issn 2214-5095
publishDate 2019-12-01
description The global needs associated with aging sewers in infrastructures are immense; moreover, traditional renewal by replacement is very costly and not fast enough to meet the renewal needs. To keep up with the rate of deterioration, different rehabilitation technologies, such as the use of polymeric lining, have seen increasing use worldwide. Pipe lining is a solution to stabilize the deterioration of the host pipes in order to extend the service life of the piping system. However, the properties of polymeric materials may degrade over time; therefore, the long-term performance of these lined pipes is a frequently raised concern in the field. The aim of this study was to investigate the state of sewers that had been previously renewed, in order to gather information that facilitates an understanding of the changes in properties of the lining materials after installation. Moreover, to identify the general issues related to pipeline rehabilitation with polymeric systems. The samples investigated in this work had three different types of linings, service times ranging from one week to ten years, were installed by five separate installation companies and had been removed from residential buildings located in different parts of Sweden. The state of the polymeric lining and the relined samples were studied by means of tests including microscopy and visual inspection, as well as thermal analysis such as dynamic mechanical analysis (DMA) and differential scanning calorimetry (DSC), mechanical testing, such as tensile and flexural testing, and thickness measurements. Keywords: Rehabilitation, Pipe lining, Sewer, Cured in place pipe, Coating, Pipe renewal
url http://www.sciencedirect.com/science/article/pii/S2214509519303936
work_keys_str_mv AT parastoukharazmi experimentalassessmentofthestateoftheliningmaterialsusedintherehabilitationofsewersinresidentialbuildings
_version_ 1725153255886946304