Experimental and Theoretical Substantiation of the Express Method Development for Detection of Enteroviruses in Water by Surface Plasmon Resonance Method

Background. As a result of anthropogenic pollution and number of other factors, in drinking water can be present some viruses such as enterovirus and other pathogens that can be transmitted by water. Enteroviruses are capable of causing lesions of organs and systems of varying severity in humans, ma...

Full description

Bibliographic Details
Main Authors: Zinaida Klestova, Alla Yuschenko, Oksana Blotska, Volodymyr Maslov, Yurii Ushenin, Glib Dorozinsky, Serhii Kravchenko, Hanna Dorozinska
Format: Article
Language:English
Published: Igor Sikorsky Kyiv Polytechnic Institute 2019-04-01
Series:Innovative Biosystems and Bioengineering
Subjects:
Online Access:http://ibb.kpi.ua/article/view/163106
id doaj-2b5aac633b4e47aa9ae439723e37a83e
record_format Article
spelling doaj-2b5aac633b4e47aa9ae439723e37a83e2021-02-02T03:16:26ZengIgor Sikorsky Kyiv Polytechnic InstituteInnovative Biosystems and Bioengineering2616-177X2019-04-0131526010.20535/ibb.2019.3.1.163106163106Experimental and Theoretical Substantiation of the Express Method Development for Detection of Enteroviruses in Water by Surface Plasmon Resonance MethodZinaida Klestova0Alla Yuschenko1Oksana Blotska2Volodymyr Maslov3Yurii Ushenin4Glib Dorozinsky5Serhii Kravchenko6Hanna Dorozinska7State Scientific-Control Institute of Biotechnology and Strains of MicroorganismsState Scientific-Control Institute of Biotechnology and Strains of MicroorganismsState Scientific-Control Institute of Biotechnology and Strains of MicroorganismsV.Ye. Lashkaryov Institute of Semiconductor Physics, NAS of UkraineV.Ye. Lashkaryov Institute of Semiconductor Physics, NAS of UkraineV.Ye. Lashkaryov Institute of Semiconductor Physics, NAS of UkraineV.Ye. Lashkaryov Institute of Semiconductor Physics, NAS of UkraineIgor Sikorsky Kyiv Polytechnic InstituteBackground. As a result of anthropogenic pollution and number of other factors, in drinking water can be present some viruses such as enterovirus and other pathogens that can be transmitted by water. Enteroviruses are capable of causing lesions of organs and systems of varying severity in humans, manifested by a number of clinical symptoms. For the detection of viruses appropriate research methods were developed, but they take a lot of time and require special reagents and equipment, that is significant drawback of sanitary-virological studies of drinking water quality. Objective. The aim of the paper is to study the general possibility of using a surface plasmon resonance (SPR) phenomenon for detection of enteroviruses in water samples (swine Teschovirus A as an example) and to create on its basis a new express diagnostic method. Methods. For implementation of a method for rapid detection of viral diseases pathogens in water by using SPR, the Plasmon-6 device was developed at the Institute of V.E. Lashkaryov Institute of Semiconductor Physics NAS of Ukraine. The research on the interaction of antigen and specific serum in various buffers was held at the State Scientific Control Institute of Biotechnology and Strains of Microorganisms. Results. A general possibility of using SPR to detect enteroviruses in distilled and drinking water (swine Teschovirus A as an example) was theoretically substantiated and experimentally proved, and the express method for their detection was developed. It is shown that upon detection of pathogen in distilled water, the response of the SPR sensor is 1.57 times higher than in drinking water, which may be due to the influence of ionic composition in water on the interaction of the antigen with the antibody. The developed method allows real-time monitoring of changes in the test environment, significantly reduces the duration of enteroviruses detection and does not require the use of expensive nutrient media and reagents. Сonclusions. The possibility of using the SPR method and the "Plasmon-6" device implementing this method for express detection of enteroviruses in distilled and drinking water was theoretically substantiated and experimentally proved.http://ibb.kpi.ua/article/view/163106EnterovirusesSurface plasmon resonanceWaterDetection of the pathogenRapid method
collection DOAJ
language English
format Article
sources DOAJ
author Zinaida Klestova
Alla Yuschenko
Oksana Blotska
Volodymyr Maslov
Yurii Ushenin
Glib Dorozinsky
Serhii Kravchenko
Hanna Dorozinska
spellingShingle Zinaida Klestova
Alla Yuschenko
Oksana Blotska
Volodymyr Maslov
Yurii Ushenin
Glib Dorozinsky
Serhii Kravchenko
Hanna Dorozinska
Experimental and Theoretical Substantiation of the Express Method Development for Detection of Enteroviruses in Water by Surface Plasmon Resonance Method
Innovative Biosystems and Bioengineering
Enteroviruses
Surface plasmon resonance
Water
Detection of the pathogen
Rapid method
author_facet Zinaida Klestova
Alla Yuschenko
Oksana Blotska
Volodymyr Maslov
Yurii Ushenin
Glib Dorozinsky
Serhii Kravchenko
Hanna Dorozinska
author_sort Zinaida Klestova
title Experimental and Theoretical Substantiation of the Express Method Development for Detection of Enteroviruses in Water by Surface Plasmon Resonance Method
title_short Experimental and Theoretical Substantiation of the Express Method Development for Detection of Enteroviruses in Water by Surface Plasmon Resonance Method
title_full Experimental and Theoretical Substantiation of the Express Method Development for Detection of Enteroviruses in Water by Surface Plasmon Resonance Method
title_fullStr Experimental and Theoretical Substantiation of the Express Method Development for Detection of Enteroviruses in Water by Surface Plasmon Resonance Method
title_full_unstemmed Experimental and Theoretical Substantiation of the Express Method Development for Detection of Enteroviruses in Water by Surface Plasmon Resonance Method
title_sort experimental and theoretical substantiation of the express method development for detection of enteroviruses in water by surface plasmon resonance method
publisher Igor Sikorsky Kyiv Polytechnic Institute
series Innovative Biosystems and Bioengineering
issn 2616-177X
publishDate 2019-04-01
description Background. As a result of anthropogenic pollution and number of other factors, in drinking water can be present some viruses such as enterovirus and other pathogens that can be transmitted by water. Enteroviruses are capable of causing lesions of organs and systems of varying severity in humans, manifested by a number of clinical symptoms. For the detection of viruses appropriate research methods were developed, but they take a lot of time and require special reagents and equipment, that is significant drawback of sanitary-virological studies of drinking water quality. Objective. The aim of the paper is to study the general possibility of using a surface plasmon resonance (SPR) phenomenon for detection of enteroviruses in water samples (swine Teschovirus A as an example) and to create on its basis a new express diagnostic method. Methods. For implementation of a method for rapid detection of viral diseases pathogens in water by using SPR, the Plasmon-6 device was developed at the Institute of V.E. Lashkaryov Institute of Semiconductor Physics NAS of Ukraine. The research on the interaction of antigen and specific serum in various buffers was held at the State Scientific Control Institute of Biotechnology and Strains of Microorganisms. Results. A general possibility of using SPR to detect enteroviruses in distilled and drinking water (swine Teschovirus A as an example) was theoretically substantiated and experimentally proved, and the express method for their detection was developed. It is shown that upon detection of pathogen in distilled water, the response of the SPR sensor is 1.57 times higher than in drinking water, which may be due to the influence of ionic composition in water on the interaction of the antigen with the antibody. The developed method allows real-time monitoring of changes in the test environment, significantly reduces the duration of enteroviruses detection and does not require the use of expensive nutrient media and reagents. Сonclusions. The possibility of using the SPR method and the "Plasmon-6" device implementing this method for express detection of enteroviruses in distilled and drinking water was theoretically substantiated and experimentally proved.
topic Enteroviruses
Surface plasmon resonance
Water
Detection of the pathogen
Rapid method
url http://ibb.kpi.ua/article/view/163106
work_keys_str_mv AT zinaidaklestova experimentalandtheoreticalsubstantiationoftheexpressmethoddevelopmentfordetectionofenterovirusesinwaterbysurfaceplasmonresonancemethod
AT allayuschenko experimentalandtheoreticalsubstantiationoftheexpressmethoddevelopmentfordetectionofenterovirusesinwaterbysurfaceplasmonresonancemethod
AT oksanablotska experimentalandtheoreticalsubstantiationoftheexpressmethoddevelopmentfordetectionofenterovirusesinwaterbysurfaceplasmonresonancemethod
AT volodymyrmaslov experimentalandtheoreticalsubstantiationoftheexpressmethoddevelopmentfordetectionofenterovirusesinwaterbysurfaceplasmonresonancemethod
AT yuriiushenin experimentalandtheoreticalsubstantiationoftheexpressmethoddevelopmentfordetectionofenterovirusesinwaterbysurfaceplasmonresonancemethod
AT glibdorozinsky experimentalandtheoreticalsubstantiationoftheexpressmethoddevelopmentfordetectionofenterovirusesinwaterbysurfaceplasmonresonancemethod
AT serhiikravchenko experimentalandtheoreticalsubstantiationoftheexpressmethoddevelopmentfordetectionofenterovirusesinwaterbysurfaceplasmonresonancemethod
AT hannadorozinska experimentalandtheoreticalsubstantiationoftheexpressmethoddevelopmentfordetectionofenterovirusesinwaterbysurfaceplasmonresonancemethod
_version_ 1724308229610012672