Compensation for the Effects of Ambient Conditions on the Calibration of Multi-Capillary Pressure Drop Standards

Cigarette draw resistance and filter pressure drop (PD) are both major physical parameters for the tobacco industry. Therefore these parameters must be measured reliably. For these measurements, specific equipment calibrated with PD transfer standards is used. Each transfer standard must have a know...

Full description

Bibliographic Details
Main Authors: Colard S, Trinkies W, Cholet G, Camm B, Austin M, Gualandris R
Format: Article
Language:English
Published: Sciendo 2004-10-01
Series:Beiträge zur Tabakforschung International
Online Access:https://doi.org/10.2478/cttr-2013-0777
Description
Summary:Cigarette draw resistance and filter pressure drop (PD) are both major physical parameters for the tobacco industry. Therefore these parameters must be measured reliably. For these measurements, specific equipment calibrated with PD transfer standards is used. Each transfer standard must have a known and stable PD value, such standards usually being composed of several capillary tubes associated in parallel. However, PD values are modified by ambient conditions during calibration of such standards, i.e. by temperature and relative humidity (RH) of air, and atmospheric pressure. In order to reduce the influence of these ambient factors, a simplified model was developed for compensating the effects of ambient conditions on the calibration of multi-capillary PD standards.
ISSN:1612-9237