Dose volume histogram analysis and comparison of different radiobiological models using in-house developed software
The purpose of this study is to compare Lyman-Kutcher-Burman (LKB) model versus Niemierko model for normal tissue complication probability (NTCP) calculation and Niemierko model versus Poisson-based model for tumor control probability (TCP) calculation in the ranking of different treatment plans for...
Main Authors: | , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Wolters Kluwer Medknow Publications
2011-01-01
|
Series: | Journal of Medical Physics |
Subjects: | |
Online Access: | http://www.jmp.org.in/article.asp?issn=0971-6203;year=2011;volume=36;issue=4;spage=220;epage=229;aulast=Oinam |
id |
doaj-2acda1e00f1c49ab8d32911ba1332c21 |
---|---|
record_format |
Article |
spelling |
doaj-2acda1e00f1c49ab8d32911ba1332c212020-11-24T23:34:35ZengWolters Kluwer Medknow PublicationsJournal of Medical Physics0971-62031998-39132011-01-0136422022910.4103/0971-6203.89971Dose volume histogram analysis and comparison of different radiobiological models using in-house developed softwareArun S OinamLakhwant SinghArvind ShuklaSushmita GhoshalRakesh KapoorSuresh C SharmaThe purpose of this study is to compare Lyman-Kutcher-Burman (LKB) model versus Niemierko model for normal tissue complication probability (NTCP) calculation and Niemierko model versus Poisson-based model for tumor control probability (TCP) calculation in the ranking of different treatment plans for a patient undergoing radiotherapy. The standard normal tissue tolerance data were used to test the NTCP models. LKB model can reproduce the same complication probability data of normal tissue response on radiation, whereas Niemierko model cannot reproduce the same complication probability. Both Poisson-based and Niemierko models equally reproduce the same standard TCP data in testing of TCP. In case of clinical data generated from treatment planning system, NTCP calculated using LKB model was found to be different from that calculated using Niemierko model. When the fractionation effect was considered in LKB model, the calculated values of NTCPs were different but comparable with those of Niemierko model. In case of TCP calculation using these models, Poisson-based model calculated marginally higher control probability as compared to Niemierko model.http://www.jmp.org.in/article.asp?issn=0971-6203;year=2011;volume=36;issue=4;spage=220;epage=229;aulast=OinamNiemierko modelnormal tissue complication probabilityPoisson-based model and Lyman-Kutcher-Burman modeltumor control probability |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Arun S Oinam Lakhwant Singh Arvind Shukla Sushmita Ghoshal Rakesh Kapoor Suresh C Sharma |
spellingShingle |
Arun S Oinam Lakhwant Singh Arvind Shukla Sushmita Ghoshal Rakesh Kapoor Suresh C Sharma Dose volume histogram analysis and comparison of different radiobiological models using in-house developed software Journal of Medical Physics Niemierko model normal tissue complication probability Poisson-based model and Lyman-Kutcher-Burman model tumor control probability |
author_facet |
Arun S Oinam Lakhwant Singh Arvind Shukla Sushmita Ghoshal Rakesh Kapoor Suresh C Sharma |
author_sort |
Arun S Oinam |
title |
Dose volume histogram analysis and comparison of different radiobiological models using in-house developed software |
title_short |
Dose volume histogram analysis and comparison of different radiobiological models using in-house developed software |
title_full |
Dose volume histogram analysis and comparison of different radiobiological models using in-house developed software |
title_fullStr |
Dose volume histogram analysis and comparison of different radiobiological models using in-house developed software |
title_full_unstemmed |
Dose volume histogram analysis and comparison of different radiobiological models using in-house developed software |
title_sort |
dose volume histogram analysis and comparison of different radiobiological models using in-house developed software |
publisher |
Wolters Kluwer Medknow Publications |
series |
Journal of Medical Physics |
issn |
0971-6203 1998-3913 |
publishDate |
2011-01-01 |
description |
The purpose of this study is to compare Lyman-Kutcher-Burman (LKB) model versus Niemierko model for normal tissue complication probability (NTCP) calculation and Niemierko model versus Poisson-based model for tumor control probability (TCP) calculation in the ranking of different treatment plans for a patient undergoing radiotherapy. The standard normal tissue tolerance data were used to test the NTCP models. LKB model can reproduce the same complication probability data of normal tissue response on radiation, whereas Niemierko model cannot reproduce the same complication probability. Both Poisson-based and Niemierko models equally reproduce the same standard TCP data in testing of TCP. In case of clinical data generated from treatment planning system, NTCP calculated using LKB model was found to be different from that calculated using Niemierko model. When the fractionation effect was considered in LKB model, the calculated values of NTCPs were different but comparable with those of Niemierko model. In case of TCP calculation using these models, Poisson-based model calculated marginally higher control probability as compared to Niemierko model. |
topic |
Niemierko model normal tissue complication probability Poisson-based model and Lyman-Kutcher-Burman model tumor control probability |
url |
http://www.jmp.org.in/article.asp?issn=0971-6203;year=2011;volume=36;issue=4;spage=220;epage=229;aulast=Oinam |
work_keys_str_mv |
AT arunsoinam dosevolumehistogramanalysisandcomparisonofdifferentradiobiologicalmodelsusinginhousedevelopedsoftware AT lakhwantsingh dosevolumehistogramanalysisandcomparisonofdifferentradiobiologicalmodelsusinginhousedevelopedsoftware AT arvindshukla dosevolumehistogramanalysisandcomparisonofdifferentradiobiologicalmodelsusinginhousedevelopedsoftware AT sushmitaghoshal dosevolumehistogramanalysisandcomparisonofdifferentradiobiologicalmodelsusinginhousedevelopedsoftware AT rakeshkapoor dosevolumehistogramanalysisandcomparisonofdifferentradiobiologicalmodelsusinginhousedevelopedsoftware AT sureshcsharma dosevolumehistogramanalysisandcomparisonofdifferentradiobiologicalmodelsusinginhousedevelopedsoftware |
_version_ |
1725528615163002880 |