Comparison of the four proposed Apgar scoring systems in the assessment of birth asphyxia and adverse early neurologic outcomes.

<h4>Objectives</h4>To compare the Conventional, Specified, Expanded and Combined Apgar scoring systems in predicting birth asphyxia and the adverse early neurologic outcomes.<h4>Methods</h4>This prospective cohort study was conducted on 464 admitted neonates. In the delivery...

Full description

Bibliographic Details
Main Authors: Hosein Dalili, Firouzeh Nili, Mahdi Sheikh, Amir Kamal Hardani, Mamak Shariat, Fatemeh Nayeri
Format: Article
Language:English
Published: Public Library of Science (PLoS) 2015-01-01
Series:PLoS ONE
Online Access:https://doi.org/10.1371/journal.pone.0122116
Description
Summary:<h4>Objectives</h4>To compare the Conventional, Specified, Expanded and Combined Apgar scoring systems in predicting birth asphyxia and the adverse early neurologic outcomes.<h4>Methods</h4>This prospective cohort study was conducted on 464 admitted neonates. In the delivery room, after delivery the umbilical cord was double clamped and a blood samples was obtained from the umbilical artery for blood gas analysis, meanwhile on the 1- , 5- and 10- minutes Conventional, Specified, Expanded, and Combined Apgar scores were recorded. Then the neonates were followed and intracranial ultrasound imaging was performed, and the following information were recorded: the occurrence of birth asphyxia, hypoxic Ischemic Encephalopathy (HIE), intraventricular hemorrhage (IVH), and neonatal seizure.<h4>Results</h4>The Combined-Apgar score had the highest sensitivity (97%) and specificity (99%) in predicting birth asphyxia, followed by the Specified-Apgar score that was also highly sensitive (95%) and specific (97%). The Expanded-Apgar score was highly specific (95%) but not sensitive (67%) and the Conventional-Apgar score had the lowest sensitivity (81%) and low specificity (81%) in predicting birth asphyxia. When adjusted for gestational age, only the low 5-minute Combined-Apgar score was independently associated with the occurrence of HIE (B = 1.61, P = 0.02) and IVH (B = 2.8, P = 0.01).<h4>Conclusions</h4>The newly proposed Combined-Apgar score is highly sensitive and specific in predicting birth asphyxia and also is a good predictor of the occurrence of HIE and IVH in asphyxiated neonates.
ISSN:1932-6203