Performance of age-adjusted D-dimer values for predicting DVT before the knee and hip arthroplasty
Abstract Purpose To compare the specificity and sensitivity of preoperative D-dimer and age-adjusted D-dimer value for predicting the incidence of the DVT preoperatively in total joint arthroplasty (TJA) patients. Methods We enrolled 406 patients finally above 50 years old. Everyone had done ultraso...
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
BMC
2021-01-01
|
Series: | Journal of Orthopaedic Surgery and Research |
Online Access: | https://doi.org/10.1186/s13018-020-02172-w |
id |
doaj-2a76deca7e8c408789e2743b629126b8 |
---|---|
record_format |
Article |
spelling |
doaj-2a76deca7e8c408789e2743b629126b82021-01-31T16:15:56ZengBMCJournal of Orthopaedic Surgery and Research1749-799X2021-01-011611610.1186/s13018-020-02172-wPerformance of age-adjusted D-dimer values for predicting DVT before the knee and hip arthroplastyJian Xiang Wu0Jiang Hui Qing1Yao Yao2Dong Yang Chen3Qing Jiang4Department of Sports Medicine and Adult Reconstructive Surgery, Drum Tower Hospital, School of Nanjing Medical UniversityState Key Laboratory of Pharmaceutical Biotechnology, Department of Sports Medicine and Adult Reconstructive Surgery, Nanjing Drum Tower Hospital, The Affiliated Hospital of Nanjing University Medical SchoolState Key Laboratory of Pharmaceutical Biotechnology, Department of Sports Medicine and Adult Reconstructive Surgery, Nanjing Drum Tower Hospital, The Affiliated Hospital of Nanjing University Medical SchoolState Key Laboratory of Pharmaceutical Biotechnology, Department of Sports Medicine and Adult Reconstructive Surgery, Nanjing Drum Tower Hospital, The Affiliated Hospital of Nanjing University Medical SchoolState Key Laboratory of Pharmaceutical Biotechnology, Department of Sports Medicine and Adult Reconstructive Surgery, Nanjing Drum Tower Hospital, The Affiliated Hospital of Nanjing University Medical SchoolAbstract Purpose To compare the specificity and sensitivity of preoperative D-dimer and age-adjusted D-dimer value for predicting the incidence of the DVT preoperatively in total joint arthroplasty (TJA) patients. Methods We enrolled 406 patients finally above 50 years old. Everyone had done ultrasonography bedside, and D-dimer concentrations were collected before surgery. The D-dimer and age-adjusted D-dimer cut-off was calculated by multiple logistic regression and receiver operating curve (ROC) analyses. Results A total of 39 patients had found asymptomatic deep vein thrombosis (DVT) by ultrasonography. The age (odds ratio [OR] 1.067; p = 0.003) and D-dimer (OR 1.331; p = 0.025) were related to the existence of DVT. For conventional D-dimer and age-adjusted D-dimer value, the area under the curves (AUCs) were 0.685 (0.499–0.696) and 0.795 (0.611–0.881), respectively. Conclusion Compared to traditional D-dimer, age-adjusted D-dimer showed better performance in screening DVT, which was useful clinically.https://doi.org/10.1186/s13018-020-02172-w |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Jian Xiang Wu Jiang Hui Qing Yao Yao Dong Yang Chen Qing Jiang |
spellingShingle |
Jian Xiang Wu Jiang Hui Qing Yao Yao Dong Yang Chen Qing Jiang Performance of age-adjusted D-dimer values for predicting DVT before the knee and hip arthroplasty Journal of Orthopaedic Surgery and Research |
author_facet |
Jian Xiang Wu Jiang Hui Qing Yao Yao Dong Yang Chen Qing Jiang |
author_sort |
Jian Xiang Wu |
title |
Performance of age-adjusted D-dimer values for predicting DVT before the knee and hip arthroplasty |
title_short |
Performance of age-adjusted D-dimer values for predicting DVT before the knee and hip arthroplasty |
title_full |
Performance of age-adjusted D-dimer values for predicting DVT before the knee and hip arthroplasty |
title_fullStr |
Performance of age-adjusted D-dimer values for predicting DVT before the knee and hip arthroplasty |
title_full_unstemmed |
Performance of age-adjusted D-dimer values for predicting DVT before the knee and hip arthroplasty |
title_sort |
performance of age-adjusted d-dimer values for predicting dvt before the knee and hip arthroplasty |
publisher |
BMC |
series |
Journal of Orthopaedic Surgery and Research |
issn |
1749-799X |
publishDate |
2021-01-01 |
description |
Abstract Purpose To compare the specificity and sensitivity of preoperative D-dimer and age-adjusted D-dimer value for predicting the incidence of the DVT preoperatively in total joint arthroplasty (TJA) patients. Methods We enrolled 406 patients finally above 50 years old. Everyone had done ultrasonography bedside, and D-dimer concentrations were collected before surgery. The D-dimer and age-adjusted D-dimer cut-off was calculated by multiple logistic regression and receiver operating curve (ROC) analyses. Results A total of 39 patients had found asymptomatic deep vein thrombosis (DVT) by ultrasonography. The age (odds ratio [OR] 1.067; p = 0.003) and D-dimer (OR 1.331; p = 0.025) were related to the existence of DVT. For conventional D-dimer and age-adjusted D-dimer value, the area under the curves (AUCs) were 0.685 (0.499–0.696) and 0.795 (0.611–0.881), respectively. Conclusion Compared to traditional D-dimer, age-adjusted D-dimer showed better performance in screening DVT, which was useful clinically. |
url |
https://doi.org/10.1186/s13018-020-02172-w |
work_keys_str_mv |
AT jianxiangwu performanceofageadjustedddimervaluesforpredictingdvtbeforethekneeandhiparthroplasty AT jianghuiqing performanceofageadjustedddimervaluesforpredictingdvtbeforethekneeandhiparthroplasty AT yaoyao performanceofageadjustedddimervaluesforpredictingdvtbeforethekneeandhiparthroplasty AT dongyangchen performanceofageadjustedddimervaluesforpredictingdvtbeforethekneeandhiparthroplasty AT qingjiang performanceofageadjustedddimervaluesforpredictingdvtbeforethekneeandhiparthroplasty |
_version_ |
1724316584326987776 |