Efficient method for the global noise filtering in measuring channels of the VVER NPP leak monitoring systems
In accordance with Ref. (GOST R 58328-2018 “Pipelines of Nuclear Power Plants. Leak Before Break Concept”), NPPs with VVER-1200 reactors operate an acoustic leak monitoring system (ALMS) and a humidity leak monitoring system (HLMS), each performing the leak monitoring functions local...
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
National Research Nuclear University (MEPhI)
2021-03-01
|
Series: | Nuclear Energy and Technology |
Online Access: | https://nucet.pensoft.net/article/65446/download/pdf/ |
id |
doaj-2a3d98e720b04c3f8161c023401e6afc |
---|---|
record_format |
Article |
spelling |
doaj-2a3d98e720b04c3f8161c023401e6afc2021-09-28T14:36:45ZengNational Research Nuclear University (MEPhI)Nuclear Energy and Technology2452-30382021-03-0171677210.3897/nucet.7.6544665446Efficient method for the global noise filtering in measuring channels of the VVER NPP leak monitoring systemsYevgeniy L. Trykov0Andrey A. Kudryaev1Konstantin I. Kotsoyev2Aleksey A. Ananyev3JSC STC DiapromJSC STC DiapromN.E. Bauman Moscow State Technical UniversityJSC STC Diaprom In accordance with Ref. (GOST R 58328-2018 “Pipelines of Nuclear Power Plants. Leak Before Break Concept”), NPPs with VVER-1200 reactors operate an acoustic leak monitoring system (ALMS) and a humidity leak monitoring system (HLMS), each performing the leak monitoring functions locally, independently of the other. The diagnostics results are conveyed to the upper level control system (LCS) to be further displayed for the main control room (MCR) operating personnel. There is also an integrated diagnostics system (IDS) intended to confirm the diagnosis and to update the leak rate values and coordinates based on analyzing the leak monitoring system readings and I&C signals. The system measuring channel readings are composed of background noise, the source for which are processes on the part of the reactor facility’s key components and auxiliary systems, and the leak signal in response to the leak occurrence. A major factor that affects the capability of leak monitoring systems to detect the leak is the quality of the background noise filtering. A new efficient global noise filtering method is proposed for being used as part of the integrated diagnostics system (IDS). https://nucet.pensoft.net/article/65446/download/pdf/ |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Yevgeniy L. Trykov Andrey A. Kudryaev Konstantin I. Kotsoyev Aleksey A. Ananyev |
spellingShingle |
Yevgeniy L. Trykov Andrey A. Kudryaev Konstantin I. Kotsoyev Aleksey A. Ananyev Efficient method for the global noise filtering in measuring channels of the VVER NPP leak monitoring systems Nuclear Energy and Technology |
author_facet |
Yevgeniy L. Trykov Andrey A. Kudryaev Konstantin I. Kotsoyev Aleksey A. Ananyev |
author_sort |
Yevgeniy L. Trykov |
title |
Efficient method for the global noise filtering in measuring channels of the VVER NPP leak monitoring systems |
title_short |
Efficient method for the global noise filtering in measuring channels of the VVER NPP leak monitoring systems |
title_full |
Efficient method for the global noise filtering in measuring channels of the VVER NPP leak monitoring systems |
title_fullStr |
Efficient method for the global noise filtering in measuring channels of the VVER NPP leak monitoring systems |
title_full_unstemmed |
Efficient method for the global noise filtering in measuring channels of the VVER NPP leak monitoring systems |
title_sort |
efficient method for the global noise filtering in measuring channels of the vver npp leak monitoring systems |
publisher |
National Research Nuclear University (MEPhI) |
series |
Nuclear Energy and Technology |
issn |
2452-3038 |
publishDate |
2021-03-01 |
description |
In accordance with Ref. (GOST R 58328-2018 “Pipelines of Nuclear Power Plants. Leak Before Break Concept”), NPPs with VVER-1200 reactors operate an acoustic leak monitoring system (ALMS) and a humidity leak monitoring system (HLMS), each performing the leak monitoring functions locally, independently of the other. The diagnostics results are conveyed to the upper level control system (LCS) to be further displayed for the main control room (MCR) operating personnel. There is also an integrated diagnostics system (IDS) intended to confirm the diagnosis and to update the leak rate values and coordinates based on analyzing the leak monitoring system readings and I&C signals. The system measuring channel readings are composed of background noise, the source for which are processes on the part of the reactor facility’s key components and auxiliary systems, and the leak signal in response to the leak occurrence. A major factor that affects the capability of leak monitoring systems to detect the leak is the quality of the background noise filtering. A new efficient global noise filtering method is proposed for being used as part of the integrated diagnostics system (IDS). |
url |
https://nucet.pensoft.net/article/65446/download/pdf/ |
work_keys_str_mv |
AT yevgeniyltrykov efficientmethodfortheglobalnoisefilteringinmeasuringchannelsofthevvernppleakmonitoringsystems AT andreyakudryaev efficientmethodfortheglobalnoisefilteringinmeasuringchannelsofthevvernppleakmonitoringsystems AT konstantinikotsoyev efficientmethodfortheglobalnoisefilteringinmeasuringchannelsofthevvernppleakmonitoringsystems AT alekseyaananyev efficientmethodfortheglobalnoisefilteringinmeasuringchannelsofthevvernppleakmonitoringsystems |