Revolutionizing Therapeutic Drug Monitoring with the Use of Interstitial Fluid and Microneedles Technology

While therapeutic drug monitoring (TDM) that uses blood as the biological matrix is the traditional gold standard, this practice may be impossible, impractical, or unethical for some patient populations (e.g., elderly, pediatric, anemic) and those with fragile veins. In the context of finding an alt...

Full description

Bibliographic Details
Main Authors: Tony K.L. Kiang, Sahan A. Ranamukhaarachchi, Mary H.H. Ensom
Format: Article
Language:English
Published: MDPI AG 2017-10-01
Series:Pharmaceutics
Subjects:
Online Access:https://www.mdpi.com/1999-4923/9/4/43
id doaj-29e9e725370a4c0596182d4c1aafc011
record_format Article
spelling doaj-29e9e725370a4c0596182d4c1aafc0112020-11-25T00:09:36ZengMDPI AGPharmaceutics1999-49232017-10-01944310.3390/pharmaceutics9040043pharmaceutics9040043Revolutionizing Therapeutic Drug Monitoring with the Use of Interstitial Fluid and Microneedles TechnologyTony K.L. Kiang0Sahan A. Ranamukhaarachchi1Mary H.H. Ensom2Faculty of Pharmacy and Pharmaceutical Sciences, University of Alberta, Edmonton, AB T6G 2E1, CanadaDepartment of Electrical and Computer Engineering, University of British Columbia, Vancouver, BC V6T 1Z4, CanadaFaculty of Pharmaceutical Sciences, University of British Columbia, Vancouver, BC V6T 1Z3, CanadaWhile therapeutic drug monitoring (TDM) that uses blood as the biological matrix is the traditional gold standard, this practice may be impossible, impractical, or unethical for some patient populations (e.g., elderly, pediatric, anemic) and those with fragile veins. In the context of finding an alternative biological matrix for TDM, this manuscript will provide a qualitative review on: (1) the principles of TDM; (2) alternative matrices for TDM; (3) current evidence supporting the use of interstitial fluid (ISF) for TDM in clinical models; (4) the use of microneedle technologies, which is potentially minimally invasive and pain-free, for the collection of ISF; and (5) future directions. The current state of knowledge on the use of ISF for TDM in humans is still limited. A thorough literature review indicates that only a few drug classes have been investigated (i.e., anti-infectives, anticonvulsants, and miscellaneous other agents). Studies have successfully demonstrated techniques for ISF extraction from the skin but have failed to demonstrate commercial feasibility of ISF extraction followed by analysis of its content outside the ISF-collecting microneedle device. In contrast, microneedle-integrated biosensors built to extract ISF and perform the biomolecule analysis on-device, with a key feature of not needing to transfer ISF to a separate instrument, have yielded promising results that need to be validated in pre-clinical and clinical studies. The most promising applications for microneedle-integrated biosensors is continuous monitoring of biomolecules from the skin’s ISF. Conducting TDM using ISF is at the stage where its clinical utility should be investigated. Based on the advancements described in the current review, the immediate future direction for this area of research is to establish the suitability of using ISF for TDM in human models for drugs that have been found suitable in pre-clinical experiments.https://www.mdpi.com/1999-4923/9/4/43clinical pharmacokineticstherapeutic drug monitoringinterstitial fluidmicroneedles
collection DOAJ
language English
format Article
sources DOAJ
author Tony K.L. Kiang
Sahan A. Ranamukhaarachchi
Mary H.H. Ensom
spellingShingle Tony K.L. Kiang
Sahan A. Ranamukhaarachchi
Mary H.H. Ensom
Revolutionizing Therapeutic Drug Monitoring with the Use of Interstitial Fluid and Microneedles Technology
Pharmaceutics
clinical pharmacokinetics
therapeutic drug monitoring
interstitial fluid
microneedles
author_facet Tony K.L. Kiang
Sahan A. Ranamukhaarachchi
Mary H.H. Ensom
author_sort Tony K.L. Kiang
title Revolutionizing Therapeutic Drug Monitoring with the Use of Interstitial Fluid and Microneedles Technology
title_short Revolutionizing Therapeutic Drug Monitoring with the Use of Interstitial Fluid and Microneedles Technology
title_full Revolutionizing Therapeutic Drug Monitoring with the Use of Interstitial Fluid and Microneedles Technology
title_fullStr Revolutionizing Therapeutic Drug Monitoring with the Use of Interstitial Fluid and Microneedles Technology
title_full_unstemmed Revolutionizing Therapeutic Drug Monitoring with the Use of Interstitial Fluid and Microneedles Technology
title_sort revolutionizing therapeutic drug monitoring with the use of interstitial fluid and microneedles technology
publisher MDPI AG
series Pharmaceutics
issn 1999-4923
publishDate 2017-10-01
description While therapeutic drug monitoring (TDM) that uses blood as the biological matrix is the traditional gold standard, this practice may be impossible, impractical, or unethical for some patient populations (e.g., elderly, pediatric, anemic) and those with fragile veins. In the context of finding an alternative biological matrix for TDM, this manuscript will provide a qualitative review on: (1) the principles of TDM; (2) alternative matrices for TDM; (3) current evidence supporting the use of interstitial fluid (ISF) for TDM in clinical models; (4) the use of microneedle technologies, which is potentially minimally invasive and pain-free, for the collection of ISF; and (5) future directions. The current state of knowledge on the use of ISF for TDM in humans is still limited. A thorough literature review indicates that only a few drug classes have been investigated (i.e., anti-infectives, anticonvulsants, and miscellaneous other agents). Studies have successfully demonstrated techniques for ISF extraction from the skin but have failed to demonstrate commercial feasibility of ISF extraction followed by analysis of its content outside the ISF-collecting microneedle device. In contrast, microneedle-integrated biosensors built to extract ISF and perform the biomolecule analysis on-device, with a key feature of not needing to transfer ISF to a separate instrument, have yielded promising results that need to be validated in pre-clinical and clinical studies. The most promising applications for microneedle-integrated biosensors is continuous monitoring of biomolecules from the skin’s ISF. Conducting TDM using ISF is at the stage where its clinical utility should be investigated. Based on the advancements described in the current review, the immediate future direction for this area of research is to establish the suitability of using ISF for TDM in human models for drugs that have been found suitable in pre-clinical experiments.
topic clinical pharmacokinetics
therapeutic drug monitoring
interstitial fluid
microneedles
url https://www.mdpi.com/1999-4923/9/4/43
work_keys_str_mv AT tonyklkiang revolutionizingtherapeuticdrugmonitoringwiththeuseofinterstitialfluidandmicroneedlestechnology
AT sahanaranamukhaarachchi revolutionizingtherapeuticdrugmonitoringwiththeuseofinterstitialfluidandmicroneedlestechnology
AT maryhhensom revolutionizingtherapeuticdrugmonitoringwiththeuseofinterstitialfluidandmicroneedlestechnology
_version_ 1725410987391057920