Evaluation of SIPIC01 and SIPIC02 on Motor Speed Control

Due to its simplicity, Proportional-Integral (PI) controller still remains as the widely used controller for motor speed control system. However, PI controller exhibits windup phenomenon when the motor operates in a saturated state, which may cause degradation to the control system. In order to over...

Full description

Bibliographic Details
Main Authors: Wong Kah Kit, Hoo Choon Lih, Mohyi Mohd Hardie Hidayat
Format: Article
Language:English
Published: EDP Sciences 2018-01-01
Series:MATEC Web of Conferences
Online Access:https://doi.org/10.1051/matecconf/201815202010
id doaj-29cf900ef02345dca43db42ea6bfc995
record_format Article
spelling doaj-29cf900ef02345dca43db42ea6bfc9952021-02-02T01:51:12ZengEDP SciencesMATEC Web of Conferences2261-236X2018-01-011520201010.1051/matecconf/201815202010matecconf_eureca2018_02010Evaluation of SIPIC01 and SIPIC02 on Motor Speed ControlWong Kah KitHoo Choon LihMohyi Mohd Hardie HidayatDue to its simplicity, Proportional-Integral (PI) controller still remains as the widely used controller for motor speed control system. However, PI controller exhibits windup phenomenon when the motor operates in a saturated state, which may cause degradation to the control system. In order to overcome the windup phenomenon, many researches have introduced various types of anti-windup methods such as the Conditioning Technique (CI), Tracking Back Calculation (TBC), Integral State Prediction (ISP), Steady-state Integral Proportional Integral Controller-01 (SIPIC01) and Steady-state Integral Proportional Integral Controller-02 (SIPIC02). These are anti-windup techniques with integral control switching mechanism, coupling of proportional gain, kp, and integral gain, ki. Due to the coupled kp and ki, tuning motor performance is a difficult task with short settling time without experiencing overshoot. SIPIC01 and SIPIC02 are robust anti-windup methods without a switching mechanism and exhibit decoupling feature. SIPIC01 and SIPIC02 have shown better dynamic performance compared to CI, TBC and ISP. However, SIPIC01 has not been compared to SIPIC02 in terms of their decoupling effect flexibility and dynamic performance. The decoupling effect was verified using MATLAB simulation, while the performance analysis was verified through hardware simulation and testing by using Scilab. The results obtained from the simulation showed that both SIPIC01 and SIPIC02 consist of decoupling features that allow a performance with coexistence of zero or minimum overshoot with short settling time. However, SIPIC02 consists of longer rise and settling time as compared to SIPIC01. Therefore, it can be concluded that SIPIC01 is better than SIPIC02 in term of dynamic performance.https://doi.org/10.1051/matecconf/201815202010
collection DOAJ
language English
format Article
sources DOAJ
author Wong Kah Kit
Hoo Choon Lih
Mohyi Mohd Hardie Hidayat
spellingShingle Wong Kah Kit
Hoo Choon Lih
Mohyi Mohd Hardie Hidayat
Evaluation of SIPIC01 and SIPIC02 on Motor Speed Control
MATEC Web of Conferences
author_facet Wong Kah Kit
Hoo Choon Lih
Mohyi Mohd Hardie Hidayat
author_sort Wong Kah Kit
title Evaluation of SIPIC01 and SIPIC02 on Motor Speed Control
title_short Evaluation of SIPIC01 and SIPIC02 on Motor Speed Control
title_full Evaluation of SIPIC01 and SIPIC02 on Motor Speed Control
title_fullStr Evaluation of SIPIC01 and SIPIC02 on Motor Speed Control
title_full_unstemmed Evaluation of SIPIC01 and SIPIC02 on Motor Speed Control
title_sort evaluation of sipic01 and sipic02 on motor speed control
publisher EDP Sciences
series MATEC Web of Conferences
issn 2261-236X
publishDate 2018-01-01
description Due to its simplicity, Proportional-Integral (PI) controller still remains as the widely used controller for motor speed control system. However, PI controller exhibits windup phenomenon when the motor operates in a saturated state, which may cause degradation to the control system. In order to overcome the windup phenomenon, many researches have introduced various types of anti-windup methods such as the Conditioning Technique (CI), Tracking Back Calculation (TBC), Integral State Prediction (ISP), Steady-state Integral Proportional Integral Controller-01 (SIPIC01) and Steady-state Integral Proportional Integral Controller-02 (SIPIC02). These are anti-windup techniques with integral control switching mechanism, coupling of proportional gain, kp, and integral gain, ki. Due to the coupled kp and ki, tuning motor performance is a difficult task with short settling time without experiencing overshoot. SIPIC01 and SIPIC02 are robust anti-windup methods without a switching mechanism and exhibit decoupling feature. SIPIC01 and SIPIC02 have shown better dynamic performance compared to CI, TBC and ISP. However, SIPIC01 has not been compared to SIPIC02 in terms of their decoupling effect flexibility and dynamic performance. The decoupling effect was verified using MATLAB simulation, while the performance analysis was verified through hardware simulation and testing by using Scilab. The results obtained from the simulation showed that both SIPIC01 and SIPIC02 consist of decoupling features that allow a performance with coexistence of zero or minimum overshoot with short settling time. However, SIPIC02 consists of longer rise and settling time as compared to SIPIC01. Therefore, it can be concluded that SIPIC01 is better than SIPIC02 in term of dynamic performance.
url https://doi.org/10.1051/matecconf/201815202010
work_keys_str_mv AT wongkahkit evaluationofsipic01andsipic02onmotorspeedcontrol
AT hoochoonlih evaluationofsipic01andsipic02onmotorspeedcontrol
AT mohyimohdhardiehidayat evaluationofsipic01andsipic02onmotorspeedcontrol
_version_ 1724310826152624128