Analysis of the possibilities for improvement of thermal comfort of living quarters located in multi-family large-panel prefabricated buildings

The article discusses the issue of low thermal insulation of partitions in large-panel prefabricated buildings. They were constructed mainly in the 70's and the 80's of the twentieth century. Defects related to freezing as well as vertical and horizontal joints of prefabricated walls, bega...

Full description

Bibliographic Details
Main Authors: Podawca Konrad, Pawłat-Zawrzykraj Agata, Dohojda Marek
Format: Article
Language:English
Published: EDP Sciences 2018-01-01
Series:E3S Web of Conferences
Online Access:https://doi.org/10.1051/e3sconf/20184400145
id doaj-299f54bf25ff4c2bbad753573436a3df
record_format Article
spelling doaj-299f54bf25ff4c2bbad753573436a3df2021-02-02T06:49:12ZengEDP SciencesE3S Web of Conferences2267-12422018-01-01440014510.1051/e3sconf/20184400145e3sconf_eko-dok2018_00145Analysis of the possibilities for improvement of thermal comfort of living quarters located in multi-family large-panel prefabricated buildingsPodawca KonradPawłat-Zawrzykraj AgataDohojda MarekThe article discusses the issue of low thermal insulation of partitions in large-panel prefabricated buildings. They were constructed mainly in the 70's and the 80's of the twentieth century. Defects related to freezing as well as vertical and horizontal joints of prefabricated walls, began to appear as early as in the very first years of operation. It was very burdensome for flat users due to lack of thermal comfort, mycological problems and rising heating costs. The thermovision analysis covered sections of panel partitions in real estate at Lazurowa Street in Warsaw, which is a four-storey multi-family building, constructed in large-panel system. The measurements were carried out in the periods of January-February 2016 before the thermal modernization of the building, and in January 2018 after its modernization and renovation of the flat. Before-and-after comparison of thermal insulation state was made on the basis of surface temperatures of crucial spots. Furthermore, after changes in the structure of external walls were finished, thermal comfort or discomfort in the analysed room were visualised, using graphs of the optimal temperature range of walls, ceiling and floor, depending on the air temperature in the room.https://doi.org/10.1051/e3sconf/20184400145
collection DOAJ
language English
format Article
sources DOAJ
author Podawca Konrad
Pawłat-Zawrzykraj Agata
Dohojda Marek
spellingShingle Podawca Konrad
Pawłat-Zawrzykraj Agata
Dohojda Marek
Analysis of the possibilities for improvement of thermal comfort of living quarters located in multi-family large-panel prefabricated buildings
E3S Web of Conferences
author_facet Podawca Konrad
Pawłat-Zawrzykraj Agata
Dohojda Marek
author_sort Podawca Konrad
title Analysis of the possibilities for improvement of thermal comfort of living quarters located in multi-family large-panel prefabricated buildings
title_short Analysis of the possibilities for improvement of thermal comfort of living quarters located in multi-family large-panel prefabricated buildings
title_full Analysis of the possibilities for improvement of thermal comfort of living quarters located in multi-family large-panel prefabricated buildings
title_fullStr Analysis of the possibilities for improvement of thermal comfort of living quarters located in multi-family large-panel prefabricated buildings
title_full_unstemmed Analysis of the possibilities for improvement of thermal comfort of living quarters located in multi-family large-panel prefabricated buildings
title_sort analysis of the possibilities for improvement of thermal comfort of living quarters located in multi-family large-panel prefabricated buildings
publisher EDP Sciences
series E3S Web of Conferences
issn 2267-1242
publishDate 2018-01-01
description The article discusses the issue of low thermal insulation of partitions in large-panel prefabricated buildings. They were constructed mainly in the 70's and the 80's of the twentieth century. Defects related to freezing as well as vertical and horizontal joints of prefabricated walls, began to appear as early as in the very first years of operation. It was very burdensome for flat users due to lack of thermal comfort, mycological problems and rising heating costs. The thermovision analysis covered sections of panel partitions in real estate at Lazurowa Street in Warsaw, which is a four-storey multi-family building, constructed in large-panel system. The measurements were carried out in the periods of January-February 2016 before the thermal modernization of the building, and in January 2018 after its modernization and renovation of the flat. Before-and-after comparison of thermal insulation state was made on the basis of surface temperatures of crucial spots. Furthermore, after changes in the structure of external walls were finished, thermal comfort or discomfort in the analysed room were visualised, using graphs of the optimal temperature range of walls, ceiling and floor, depending on the air temperature in the room.
url https://doi.org/10.1051/e3sconf/20184400145
work_keys_str_mv AT podawcakonrad analysisofthepossibilitiesforimprovementofthermalcomfortoflivingquarterslocatedinmultifamilylargepanelprefabricatedbuildings
AT pawłatzawrzykrajagata analysisofthepossibilitiesforimprovementofthermalcomfortoflivingquarterslocatedinmultifamilylargepanelprefabricatedbuildings
AT dohojdamarek analysisofthepossibilitiesforimprovementofthermalcomfortoflivingquarterslocatedinmultifamilylargepanelprefabricatedbuildings
_version_ 1724300553075294208