Simultaneous Voltammetric/Amperometric Determination of Sulfide and Nitrite in Water at BDD Electrode

This work reported new voltammetric/amperometric-based protocols using a commercial boron-doped diamond (BDD) electrode for simple and fast simultaneous detection of sulfide and nitrite from water. Square-wave voltammetry operated under the optimized working conditions of 0.01 V step potential, 0.5...

Full description

Bibliographic Details
Main Authors: Anamaria Baciu, Magdalena Ardelean, Aniela Pop, Rodica Pode, Florica Manea
Format: Article
Language:English
Published: MDPI AG 2015-06-01
Series:Sensors
Subjects:
Online Access:http://www.mdpi.com/1424-8220/15/6/14526
id doaj-29719a276f034d318f6768249064e7bb
record_format Article
spelling doaj-29719a276f034d318f6768249064e7bb2020-11-24T23:51:49ZengMDPI AGSensors1424-82202015-06-01156145261453810.3390/s150614526s150614526Simultaneous Voltammetric/Amperometric Determination of Sulfide and Nitrite in Water at BDD ElectrodeAnamaria Baciu0Magdalena Ardelean1Aniela Pop2Rodica Pode3Florica Manea4Department of Applied Chemistry and Engineering of Inorganic Compounds and Environment, Politehnica University of Timisoara, V. Parvan no. 6, Timișoara 300223, RomaniaDepartment of Applied Chemistry and Engineering of Inorganic Compounds and Environment, Politehnica University of Timisoara, V. Parvan no. 6, Timișoara 300223, RomaniaDepartment of Applied Chemistry and Engineering of Inorganic Compounds and Environment, Politehnica University of Timisoara, V. Parvan no. 6, Timișoara 300223, RomaniaDepartment of Applied Chemistry and Engineering of Inorganic Compounds and Environment, Politehnica University of Timisoara, V. Parvan no. 6, Timișoara 300223, RomaniaDepartment of Applied Chemistry and Engineering of Inorganic Compounds and Environment, Politehnica University of Timisoara, V. Parvan no. 6, Timișoara 300223, RomaniaThis work reported new voltammetric/amperometric-based protocols using a commercial boron-doped diamond (BDD) electrode for simple and fast simultaneous detection of sulfide and nitrite from water. Square-wave voltammetry operated under the optimized working conditions of 0.01 V step potential, 0.5 V modulation amplitude and 10 Hz frequency allowed achieving the best electroanalytical parameters for the simultaneous detection of nitrite and sulfide. For practical in-field detection applications, the multiple-pulsed amperometry technique was operated under optimized conditions, i.e., −0.5 V/SCE for a duration of 0.3 s as conditioning step, +0.85 V/SCE for a duration of 3 s that assure the sulfide oxidation and +1.25 V/SCE for a duration of 0.3 s, where the nitrite oxidation occurred, which allowed the simultaneously detection of sulfide and nitrite without interference between them. Good accuracy was found for this protocol in comparison with standardized methods for each anion. Also, no interference effect was found for the cation and anion species, which are common in the water matrix.http://www.mdpi.com/1424-8220/15/6/14526simultaneous voltammetric/amperometric detectionnitritesulfideboron-doped diamond electrodesquare-wave voltammetrymultiple-pulsed amperometry
collection DOAJ
language English
format Article
sources DOAJ
author Anamaria Baciu
Magdalena Ardelean
Aniela Pop
Rodica Pode
Florica Manea
spellingShingle Anamaria Baciu
Magdalena Ardelean
Aniela Pop
Rodica Pode
Florica Manea
Simultaneous Voltammetric/Amperometric Determination of Sulfide and Nitrite in Water at BDD Electrode
Sensors
simultaneous voltammetric/amperometric detection
nitrite
sulfide
boron-doped diamond electrode
square-wave voltammetry
multiple-pulsed amperometry
author_facet Anamaria Baciu
Magdalena Ardelean
Aniela Pop
Rodica Pode
Florica Manea
author_sort Anamaria Baciu
title Simultaneous Voltammetric/Amperometric Determination of Sulfide and Nitrite in Water at BDD Electrode
title_short Simultaneous Voltammetric/Amperometric Determination of Sulfide and Nitrite in Water at BDD Electrode
title_full Simultaneous Voltammetric/Amperometric Determination of Sulfide and Nitrite in Water at BDD Electrode
title_fullStr Simultaneous Voltammetric/Amperometric Determination of Sulfide and Nitrite in Water at BDD Electrode
title_full_unstemmed Simultaneous Voltammetric/Amperometric Determination of Sulfide and Nitrite in Water at BDD Electrode
title_sort simultaneous voltammetric/amperometric determination of sulfide and nitrite in water at bdd electrode
publisher MDPI AG
series Sensors
issn 1424-8220
publishDate 2015-06-01
description This work reported new voltammetric/amperometric-based protocols using a commercial boron-doped diamond (BDD) electrode for simple and fast simultaneous detection of sulfide and nitrite from water. Square-wave voltammetry operated under the optimized working conditions of 0.01 V step potential, 0.5 V modulation amplitude and 10 Hz frequency allowed achieving the best electroanalytical parameters for the simultaneous detection of nitrite and sulfide. For practical in-field detection applications, the multiple-pulsed amperometry technique was operated under optimized conditions, i.e., −0.5 V/SCE for a duration of 0.3 s as conditioning step, +0.85 V/SCE for a duration of 3 s that assure the sulfide oxidation and +1.25 V/SCE for a duration of 0.3 s, where the nitrite oxidation occurred, which allowed the simultaneously detection of sulfide and nitrite without interference between them. Good accuracy was found for this protocol in comparison with standardized methods for each anion. Also, no interference effect was found for the cation and anion species, which are common in the water matrix.
topic simultaneous voltammetric/amperometric detection
nitrite
sulfide
boron-doped diamond electrode
square-wave voltammetry
multiple-pulsed amperometry
url http://www.mdpi.com/1424-8220/15/6/14526
work_keys_str_mv AT anamariabaciu simultaneousvoltammetricamperometricdeterminationofsulfideandnitriteinwateratbddelectrode
AT magdalenaardelean simultaneousvoltammetricamperometricdeterminationofsulfideandnitriteinwateratbddelectrode
AT anielapop simultaneousvoltammetricamperometricdeterminationofsulfideandnitriteinwateratbddelectrode
AT rodicapode simultaneousvoltammetricamperometricdeterminationofsulfideandnitriteinwateratbddelectrode
AT floricamanea simultaneousvoltammetricamperometricdeterminationofsulfideandnitriteinwateratbddelectrode
_version_ 1725475948111855616