Simultaneous Voltammetric/Amperometric Determination of Sulfide and Nitrite in Water at BDD Electrode
This work reported new voltammetric/amperometric-based protocols using a commercial boron-doped diamond (BDD) electrode for simple and fast simultaneous detection of sulfide and nitrite from water. Square-wave voltammetry operated under the optimized working conditions of 0.01 V step potential, 0.5...
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
MDPI AG
2015-06-01
|
Series: | Sensors |
Subjects: | |
Online Access: | http://www.mdpi.com/1424-8220/15/6/14526 |
id |
doaj-29719a276f034d318f6768249064e7bb |
---|---|
record_format |
Article |
spelling |
doaj-29719a276f034d318f6768249064e7bb2020-11-24T23:51:49ZengMDPI AGSensors1424-82202015-06-01156145261453810.3390/s150614526s150614526Simultaneous Voltammetric/Amperometric Determination of Sulfide and Nitrite in Water at BDD ElectrodeAnamaria Baciu0Magdalena Ardelean1Aniela Pop2Rodica Pode3Florica Manea4Department of Applied Chemistry and Engineering of Inorganic Compounds and Environment, Politehnica University of Timisoara, V. Parvan no. 6, Timișoara 300223, RomaniaDepartment of Applied Chemistry and Engineering of Inorganic Compounds and Environment, Politehnica University of Timisoara, V. Parvan no. 6, Timișoara 300223, RomaniaDepartment of Applied Chemistry and Engineering of Inorganic Compounds and Environment, Politehnica University of Timisoara, V. Parvan no. 6, Timișoara 300223, RomaniaDepartment of Applied Chemistry and Engineering of Inorganic Compounds and Environment, Politehnica University of Timisoara, V. Parvan no. 6, Timișoara 300223, RomaniaDepartment of Applied Chemistry and Engineering of Inorganic Compounds and Environment, Politehnica University of Timisoara, V. Parvan no. 6, Timișoara 300223, RomaniaThis work reported new voltammetric/amperometric-based protocols using a commercial boron-doped diamond (BDD) electrode for simple and fast simultaneous detection of sulfide and nitrite from water. Square-wave voltammetry operated under the optimized working conditions of 0.01 V step potential, 0.5 V modulation amplitude and 10 Hz frequency allowed achieving the best electroanalytical parameters for the simultaneous detection of nitrite and sulfide. For practical in-field detection applications, the multiple-pulsed amperometry technique was operated under optimized conditions, i.e., −0.5 V/SCE for a duration of 0.3 s as conditioning step, +0.85 V/SCE for a duration of 3 s that assure the sulfide oxidation and +1.25 V/SCE for a duration of 0.3 s, where the nitrite oxidation occurred, which allowed the simultaneously detection of sulfide and nitrite without interference between them. Good accuracy was found for this protocol in comparison with standardized methods for each anion. Also, no interference effect was found for the cation and anion species, which are common in the water matrix.http://www.mdpi.com/1424-8220/15/6/14526simultaneous voltammetric/amperometric detectionnitritesulfideboron-doped diamond electrodesquare-wave voltammetrymultiple-pulsed amperometry |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Anamaria Baciu Magdalena Ardelean Aniela Pop Rodica Pode Florica Manea |
spellingShingle |
Anamaria Baciu Magdalena Ardelean Aniela Pop Rodica Pode Florica Manea Simultaneous Voltammetric/Amperometric Determination of Sulfide and Nitrite in Water at BDD Electrode Sensors simultaneous voltammetric/amperometric detection nitrite sulfide boron-doped diamond electrode square-wave voltammetry multiple-pulsed amperometry |
author_facet |
Anamaria Baciu Magdalena Ardelean Aniela Pop Rodica Pode Florica Manea |
author_sort |
Anamaria Baciu |
title |
Simultaneous Voltammetric/Amperometric Determination of Sulfide and Nitrite in Water at BDD Electrode |
title_short |
Simultaneous Voltammetric/Amperometric Determination of Sulfide and Nitrite in Water at BDD Electrode |
title_full |
Simultaneous Voltammetric/Amperometric Determination of Sulfide and Nitrite in Water at BDD Electrode |
title_fullStr |
Simultaneous Voltammetric/Amperometric Determination of Sulfide and Nitrite in Water at BDD Electrode |
title_full_unstemmed |
Simultaneous Voltammetric/Amperometric Determination of Sulfide and Nitrite in Water at BDD Electrode |
title_sort |
simultaneous voltammetric/amperometric determination of sulfide and nitrite in water at bdd electrode |
publisher |
MDPI AG |
series |
Sensors |
issn |
1424-8220 |
publishDate |
2015-06-01 |
description |
This work reported new voltammetric/amperometric-based protocols using a commercial boron-doped diamond (BDD) electrode for simple and fast simultaneous detection of sulfide and nitrite from water. Square-wave voltammetry operated under the optimized working conditions of 0.01 V step potential, 0.5 V modulation amplitude and 10 Hz frequency allowed achieving the best electroanalytical parameters for the simultaneous detection of nitrite and sulfide. For practical in-field detection applications, the multiple-pulsed amperometry technique was operated under optimized conditions, i.e., −0.5 V/SCE for a duration of 0.3 s as conditioning step, +0.85 V/SCE for a duration of 3 s that assure the sulfide oxidation and +1.25 V/SCE for a duration of 0.3 s, where the nitrite oxidation occurred, which allowed the simultaneously detection of sulfide and nitrite without interference between them. Good accuracy was found for this protocol in comparison with standardized methods for each anion. Also, no interference effect was found for the cation and anion species, which are common in the water matrix. |
topic |
simultaneous voltammetric/amperometric detection nitrite sulfide boron-doped diamond electrode square-wave voltammetry multiple-pulsed amperometry |
url |
http://www.mdpi.com/1424-8220/15/6/14526 |
work_keys_str_mv |
AT anamariabaciu simultaneousvoltammetricamperometricdeterminationofsulfideandnitriteinwateratbddelectrode AT magdalenaardelean simultaneousvoltammetricamperometricdeterminationofsulfideandnitriteinwateratbddelectrode AT anielapop simultaneousvoltammetricamperometricdeterminationofsulfideandnitriteinwateratbddelectrode AT rodicapode simultaneousvoltammetricamperometricdeterminationofsulfideandnitriteinwateratbddelectrode AT floricamanea simultaneousvoltammetricamperometricdeterminationofsulfideandnitriteinwateratbddelectrode |
_version_ |
1725475948111855616 |