Experimental behavior of full-scale exterior beam-column space joints retrofitted by ferrocement layers under cyclic loading

A majority of the traditional reinforced concrete frame buildings, existing across the Middle East, lack adequate confinement in beam-column joints, or in other words, are shear deficient because they were constructed before the introduction of seismic codes for construction. This research studies t...

Full description

Bibliographic Details
Main Authors: Ibrahim G. Shaaban, Osama A. Seoud
Format: Article
Language:English
Published: Elsevier 2018-06-01
Series:Case Studies in Construction Materials
Online Access:http://www.sciencedirect.com/science/article/pii/S2214509517301924
id doaj-295f1aee6b1d47a0af53919002edd298
record_format Article
spelling doaj-295f1aee6b1d47a0af53919002edd2982020-11-24T22:14:46ZengElsevierCase Studies in Construction Materials2214-50952018-06-0186178Experimental behavior of full-scale exterior beam-column space joints retrofitted by ferrocement layers under cyclic loadingIbrahim G. Shaaban0Osama A. Seoud1University of Liverpool, UK (On Sabbatical, Benha University, Egypt); Corresponding author.Civil Engineering Department, National Research Centre, EgyptA majority of the traditional reinforced concrete frame buildings, existing across the Middle East, lack adequate confinement in beam-column joints, or in other words, are shear deficient because they were constructed before the introduction of seismic codes for construction. This research studies the experimental behavior of full-scale beam-column space (three-dimensional) joints under displacement-controlled cyclic loading. Eleven joint specimens, included a traditionally reinforced one (without adequate shear reinforcement), a reference one with sufficient shear reinforcement according to ACI 318, and nine specimens retrofitted by ferrocement layers, were experimentally tested to evaluate a retrofit technique for strengthening shear deficient beam column joints. The studied variables were the number of layers, orientation angle of expanded wire mesh per layer, and presence of steel angles in the corners of joint specimen prior to wrapping with ferrocement layers. The experimental results showed that proper shear reinforcement for the test joints, according to ACI 318, enhanced the behavior of the specimen over that of the traditionally reinforced specimens without adequate shear reinforcement. The joints retrofitted by ferrocement layers showed higher ultimate capacity, higher ultimate displacement prior to failure (better ductility), and they did not suffer heavily damage as observed for the traditionally reinforced one. Increasing the number of ferrocement layers for retrofitted specimens led to improving performance for such specimens compared to the traditionally reinforced ones in terms of enhancing the ultimate capacity and ultimate displacement. Specimens retrofitted by ferrocement layers reinforced by expanded wire mesh of 60° orientation angle showed slightly better performance than those of 45° orientation angles. Retrofitting using steel angles in addition to ferrocement layers improves the seismic performance of the specimens, achieves better stability for stiffness degradation, attains higher capacity of the dissipated energy, and reduces the vulnerability of joints to excessive damage. Based on the experimental work in this study, it is recommended to retrofit beam-column joint specimens by two ferrocement layers in addition to steel angles as stiffeners taking the orientation angle of expanded wire mesh into consideration. Keywords: Retrofitting, Beam-column space joints, Ferrocement layers, Orientation of expanded wire mesh, Ultimate capacity, Stiffness degradation, Cyclic loading, Shear deficient, Traditionally reinforced buildingshttp://www.sciencedirect.com/science/article/pii/S2214509517301924
collection DOAJ
language English
format Article
sources DOAJ
author Ibrahim G. Shaaban
Osama A. Seoud
spellingShingle Ibrahim G. Shaaban
Osama A. Seoud
Experimental behavior of full-scale exterior beam-column space joints retrofitted by ferrocement layers under cyclic loading
Case Studies in Construction Materials
author_facet Ibrahim G. Shaaban
Osama A. Seoud
author_sort Ibrahim G. Shaaban
title Experimental behavior of full-scale exterior beam-column space joints retrofitted by ferrocement layers under cyclic loading
title_short Experimental behavior of full-scale exterior beam-column space joints retrofitted by ferrocement layers under cyclic loading
title_full Experimental behavior of full-scale exterior beam-column space joints retrofitted by ferrocement layers under cyclic loading
title_fullStr Experimental behavior of full-scale exterior beam-column space joints retrofitted by ferrocement layers under cyclic loading
title_full_unstemmed Experimental behavior of full-scale exterior beam-column space joints retrofitted by ferrocement layers under cyclic loading
title_sort experimental behavior of full-scale exterior beam-column space joints retrofitted by ferrocement layers under cyclic loading
publisher Elsevier
series Case Studies in Construction Materials
issn 2214-5095
publishDate 2018-06-01
description A majority of the traditional reinforced concrete frame buildings, existing across the Middle East, lack adequate confinement in beam-column joints, or in other words, are shear deficient because they were constructed before the introduction of seismic codes for construction. This research studies the experimental behavior of full-scale beam-column space (three-dimensional) joints under displacement-controlled cyclic loading. Eleven joint specimens, included a traditionally reinforced one (without adequate shear reinforcement), a reference one with sufficient shear reinforcement according to ACI 318, and nine specimens retrofitted by ferrocement layers, were experimentally tested to evaluate a retrofit technique for strengthening shear deficient beam column joints. The studied variables were the number of layers, orientation angle of expanded wire mesh per layer, and presence of steel angles in the corners of joint specimen prior to wrapping with ferrocement layers. The experimental results showed that proper shear reinforcement for the test joints, according to ACI 318, enhanced the behavior of the specimen over that of the traditionally reinforced specimens without adequate shear reinforcement. The joints retrofitted by ferrocement layers showed higher ultimate capacity, higher ultimate displacement prior to failure (better ductility), and they did not suffer heavily damage as observed for the traditionally reinforced one. Increasing the number of ferrocement layers for retrofitted specimens led to improving performance for such specimens compared to the traditionally reinforced ones in terms of enhancing the ultimate capacity and ultimate displacement. Specimens retrofitted by ferrocement layers reinforced by expanded wire mesh of 60° orientation angle showed slightly better performance than those of 45° orientation angles. Retrofitting using steel angles in addition to ferrocement layers improves the seismic performance of the specimens, achieves better stability for stiffness degradation, attains higher capacity of the dissipated energy, and reduces the vulnerability of joints to excessive damage. Based on the experimental work in this study, it is recommended to retrofit beam-column joint specimens by two ferrocement layers in addition to steel angles as stiffeners taking the orientation angle of expanded wire mesh into consideration. Keywords: Retrofitting, Beam-column space joints, Ferrocement layers, Orientation of expanded wire mesh, Ultimate capacity, Stiffness degradation, Cyclic loading, Shear deficient, Traditionally reinforced buildings
url http://www.sciencedirect.com/science/article/pii/S2214509517301924
work_keys_str_mv AT ibrahimgshaaban experimentalbehavioroffullscaleexteriorbeamcolumnspacejointsretrofittedbyferrocementlayersundercyclicloading
AT osamaaseoud experimentalbehavioroffullscaleexteriorbeamcolumnspacejointsretrofittedbyferrocementlayersundercyclicloading
_version_ 1725797199263039488