Electrochemical Corrosion and In Vitro Bioactivity of Nano-Grained Biomedical Ti-20Nb-13Zr Alloy in a Simulated Body Fluid
The bioactivity and the corrosion protection for a novel nano-grained Ti-20Nb-13Zr at % alloy were examined in a simulated body fluid (SBF). The effect of the SPS’s temperature on the corrosion performance was investigated. The phases and microstructural details of the developed alloy were analyzed...
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
MDPI AG
2017-12-01
|
Series: | Materials |
Subjects: | |
Online Access: | https://www.mdpi.com/1996-1944/11/1/26 |
id |
doaj-294b4d07be644c1b933cc51fc337eee5 |
---|---|
record_format |
Article |
spelling |
doaj-294b4d07be644c1b933cc51fc337eee52020-11-25T02:27:33ZengMDPI AGMaterials1996-19442017-12-011112610.3390/ma11010026ma11010026Electrochemical Corrosion and In Vitro Bioactivity of Nano-Grained Biomedical Ti-20Nb-13Zr Alloy in a Simulated Body FluidMohamed A. Hussein0Madhan Kumar1Robin Drew2Nasser Al-Aqeeli3Center of Research Excellence in Corrosion, Research Institute, King Fahd University of Petroleum & Minerals (KFUPM), Dhahran 31261, Saudi ArabiaCenter of Research Excellence in Corrosion, Research Institute, King Fahd University of Petroleum & Minerals (KFUPM), Dhahran 31261, Saudi ArabiaDepartment of Mechanical and Industrial Engineering, Concordia University, Montreal, QC H3G 1M8, CanadaDepartment of Mechanical Engineering, King Fahd University of Petroleum & Minerals (KFUPM), Dhahran 31261, Saudi ArabiaThe bioactivity and the corrosion protection for a novel nano-grained Ti-20Nb-13Zr at % alloy were examined in a simulated body fluid (SBF). The effect of the SPS’s temperature on the corrosion performance was investigated. The phases and microstructural details of the developed alloy were analyzed by XRD (X-ray Diffraction), SEM (Scanning Electron Microscopy), and TEM (Transmission Electron Microscope). The electrochemical study was investigated using linear potentiodynamic polarization and electrochemical impedance spectroscopy in a SBF, and the bioactivity was examined by immersing the developed alloy in a SBF for 3, 7, and 14 days. The morphology of the depositions after immersion was examined using SEM. Alloy surface analysis after immersion in the SBF was characterized by XPS (X-ray Photoelectron Spectroscopy). The results of the bioactivity test in SBF revealed the growth of a hydroxyapatite layer on the surface of the alloy. The analysis of XPS showed the formation of protective oxides of TiO2, Ti2O3, ZrO2, Nb2O5, and a Ca3(PO4)2 compound (precursor of hydroxyapatite) deposited on the alloy surface, indicating that the presented alloy can stimulate bone formation. The corrosion resistance increased by increasing the sintering temperature and the highest corrosion resistance was obtained at 1200 °C. The improved corrosion protection was found to be related to the alloy densification. The bioactivity and the corrosion resistance of the developed nanostructured alloy in a SBF renders the nanostructured Ti-20Nb-13Zr alloy a promising candidate as an implant material.https://www.mdpi.com/1996-1944/11/1/26biomaterialelectrochemical testingpolarizationTi-Nb-Zr alloybioactivity permanent |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Mohamed A. Hussein Madhan Kumar Robin Drew Nasser Al-Aqeeli |
spellingShingle |
Mohamed A. Hussein Madhan Kumar Robin Drew Nasser Al-Aqeeli Electrochemical Corrosion and In Vitro Bioactivity of Nano-Grained Biomedical Ti-20Nb-13Zr Alloy in a Simulated Body Fluid Materials biomaterial electrochemical testing polarization Ti-Nb-Zr alloy bioactivity permanent |
author_facet |
Mohamed A. Hussein Madhan Kumar Robin Drew Nasser Al-Aqeeli |
author_sort |
Mohamed A. Hussein |
title |
Electrochemical Corrosion and In Vitro Bioactivity of Nano-Grained Biomedical Ti-20Nb-13Zr Alloy in a Simulated Body Fluid |
title_short |
Electrochemical Corrosion and In Vitro Bioactivity of Nano-Grained Biomedical Ti-20Nb-13Zr Alloy in a Simulated Body Fluid |
title_full |
Electrochemical Corrosion and In Vitro Bioactivity of Nano-Grained Biomedical Ti-20Nb-13Zr Alloy in a Simulated Body Fluid |
title_fullStr |
Electrochemical Corrosion and In Vitro Bioactivity of Nano-Grained Biomedical Ti-20Nb-13Zr Alloy in a Simulated Body Fluid |
title_full_unstemmed |
Electrochemical Corrosion and In Vitro Bioactivity of Nano-Grained Biomedical Ti-20Nb-13Zr Alloy in a Simulated Body Fluid |
title_sort |
electrochemical corrosion and in vitro bioactivity of nano-grained biomedical ti-20nb-13zr alloy in a simulated body fluid |
publisher |
MDPI AG |
series |
Materials |
issn |
1996-1944 |
publishDate |
2017-12-01 |
description |
The bioactivity and the corrosion protection for a novel nano-grained Ti-20Nb-13Zr at % alloy were examined in a simulated body fluid (SBF). The effect of the SPS’s temperature on the corrosion performance was investigated. The phases and microstructural details of the developed alloy were analyzed by XRD (X-ray Diffraction), SEM (Scanning Electron Microscopy), and TEM (Transmission Electron Microscope). The electrochemical study was investigated using linear potentiodynamic polarization and electrochemical impedance spectroscopy in a SBF, and the bioactivity was examined by immersing the developed alloy in a SBF for 3, 7, and 14 days. The morphology of the depositions after immersion was examined using SEM. Alloy surface analysis after immersion in the SBF was characterized by XPS (X-ray Photoelectron Spectroscopy). The results of the bioactivity test in SBF revealed the growth of a hydroxyapatite layer on the surface of the alloy. The analysis of XPS showed the formation of protective oxides of TiO2, Ti2O3, ZrO2, Nb2O5, and a Ca3(PO4)2 compound (precursor of hydroxyapatite) deposited on the alloy surface, indicating that the presented alloy can stimulate bone formation. The corrosion resistance increased by increasing the sintering temperature and the highest corrosion resistance was obtained at 1200 °C. The improved corrosion protection was found to be related to the alloy densification. The bioactivity and the corrosion resistance of the developed nanostructured alloy in a SBF renders the nanostructured Ti-20Nb-13Zr alloy a promising candidate as an implant material. |
topic |
biomaterial electrochemical testing polarization Ti-Nb-Zr alloy bioactivity permanent |
url |
https://www.mdpi.com/1996-1944/11/1/26 |
work_keys_str_mv |
AT mohamedahussein electrochemicalcorrosionandinvitrobioactivityofnanograinedbiomedicalti20nb13zralloyinasimulatedbodyfluid AT madhankumar electrochemicalcorrosionandinvitrobioactivityofnanograinedbiomedicalti20nb13zralloyinasimulatedbodyfluid AT robindrew electrochemicalcorrosionandinvitrobioactivityofnanograinedbiomedicalti20nb13zralloyinasimulatedbodyfluid AT nasseralaqeeli electrochemicalcorrosionandinvitrobioactivityofnanograinedbiomedicalti20nb13zralloyinasimulatedbodyfluid |
_version_ |
1724842315318558720 |