Breakdown and field emission conditioning of Cu, Mo, and W
The ultrahigh-vacuum electrical breakdown characteristics of copper, molybdenum, and tungsten have been explored in a setup based on a capacitor discharge. Upon repeated sparking, tungsten and molybdenum showed improvement of the maximum applicable field before breakdown (conditioning) in contrast t...
Main Authors: | M. Kildemo, S. Calatroni, M. Taborelli |
---|---|
Format: | Article |
Language: | English |
Published: |
American Physical Society
2004-09-01
|
Series: | Physical Review Special Topics. Accelerators and Beams |
Online Access: | http://doi.org/10.1103/PhysRevSTAB.7.092003 |
Similar Items
-
Influence of ambient gases on the dc saturated breakdown field of molybdenum, tungsten, and copper during intense breakdown conditioning
by: T. Ramsvik, et al.
Published: (2007-04-01) -
Energy dependence of processing and breakdown properties of Cu and Mo
by: H. Timko, et al.
Published: (2011-10-01) -
dc breakdown conditioning and breakdown rate of metals and metallic alloys under ultrahigh vacuum
by: A. Descoeudres, et al.
Published: (2009-03-01) -
Investigation of the dc vacuum breakdown mechanism
by: A. Descoeudres, et al.
Published: (2009-09-01) -
Intermetallic phase formation and breakdown of Mo diffusion barriers in Ni-Mo-Cu and Ni-Mo-Monel 400 diffusion triads /
by: Shueh, Yinsheng
Published: (1988)