Driving Pressure Influence in Voltage Maps Measurement Process Using Advanced Pneumatic Mapping Probe
Our paper deals with the method of the voltage-impedance map measurement process as a method useful for the electric mapping of human skin. The area of research extends from the basic research to its practical application in acupuncture skin mapping and acupuncture point localization and visualizati...
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
VSB-Technical University of Ostrava
2016-01-01
|
Series: | Advances in Electrical and Electronic Engineering |
Subjects: | |
Online Access: | http://advances.utc.sk/index.php/AEEE/article/view/1730 |
id |
doaj-28f067985581429e904116a384fbcdc3 |
---|---|
record_format |
Article |
spelling |
doaj-28f067985581429e904116a384fbcdc32021-10-11T08:03:05ZengVSB-Technical University of OstravaAdvances in Electrical and Electronic Engineering1336-13761804-31192016-01-0114217818810.15598/aeee.v14i2.1730809Driving Pressure Influence in Voltage Maps Measurement Process Using Advanced Pneumatic Mapping ProbeMarek Kukucka0Andreas Weisze1Daniela Durackova2Zuzana Krajcuskova3Viera Stopjakova4Slovak University of Technology in Bratislava, Faculty of Electrical Engineering and Information Technology, Institute of Automotive Mechatronics, researcherDr. Ing. h.c. Porsche AG, Porscheplatz 1, 70435 Stuttgart, GermanyInstitute of Electronics and Photonics, Faculty of Electrical Engineering and Information Technology, Slovak University of Technology, Ilkovicova 3, 81219 Bratislava, Slovak RepublicInstitute of Electronics and Photonics, Faculty of Electrical Engineering and Information Technology, Slovak University of Technology, Ilkovicova 3, 81219 Bratislava, Slovak RepublicInstitute of Electronics and Photonics, Faculty of Electrical Engineering and Information Technology, Slovak University of Technology, Ilkovicova 3, 81219 Bratislava, Slovak RepublicOur paper deals with the method of the voltage-impedance map measurement process as a method useful for the electric mapping of human skin. The area of research extends from the basic research to its practical application in acupuncture skin mapping and acupuncture point localization and visualization. The problem of sufficient skin coverage and electrical contact with measuring electrodes is solved by the conventional mechanical telescopic electrodes and by the pneumatic matrix electrode probe. A 2D or 3D voltage-impedance map of skin is an output of the measuring, interpretation and evaluation process. New pneumatic construction of measuring probe was implemented to achieve a better coverage of specified skin area and get a reduced force range of the touching electrodes allowing the steady contact of the skin-electrode. A skin contact is related to the driving pressure of touching electrodes. Our paper offers experimentally measured results, voltage maps of skin on specific areas, selected measured and described acupuncture points and their applications in electro-acupuncture.http://advances.utc.sk/index.php/AEEE/article/view/1730acupuncture pointdriving pressurehuman skinmeasuring probepneumatic electrodes. |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Marek Kukucka Andreas Weisze Daniela Durackova Zuzana Krajcuskova Viera Stopjakova |
spellingShingle |
Marek Kukucka Andreas Weisze Daniela Durackova Zuzana Krajcuskova Viera Stopjakova Driving Pressure Influence in Voltage Maps Measurement Process Using Advanced Pneumatic Mapping Probe Advances in Electrical and Electronic Engineering acupuncture point driving pressure human skin measuring probe pneumatic electrodes. |
author_facet |
Marek Kukucka Andreas Weisze Daniela Durackova Zuzana Krajcuskova Viera Stopjakova |
author_sort |
Marek Kukucka |
title |
Driving Pressure Influence in Voltage Maps Measurement Process Using Advanced Pneumatic Mapping Probe |
title_short |
Driving Pressure Influence in Voltage Maps Measurement Process Using Advanced Pneumatic Mapping Probe |
title_full |
Driving Pressure Influence in Voltage Maps Measurement Process Using Advanced Pneumatic Mapping Probe |
title_fullStr |
Driving Pressure Influence in Voltage Maps Measurement Process Using Advanced Pneumatic Mapping Probe |
title_full_unstemmed |
Driving Pressure Influence in Voltage Maps Measurement Process Using Advanced Pneumatic Mapping Probe |
title_sort |
driving pressure influence in voltage maps measurement process using advanced pneumatic mapping probe |
publisher |
VSB-Technical University of Ostrava |
series |
Advances in Electrical and Electronic Engineering |
issn |
1336-1376 1804-3119 |
publishDate |
2016-01-01 |
description |
Our paper deals with the method of the voltage-impedance map measurement process as a method useful for the electric mapping of human skin. The area of research extends from the basic research to its practical application in acupuncture skin mapping and acupuncture point localization and visualization. The problem of sufficient skin coverage and electrical contact with measuring electrodes is solved by the conventional mechanical telescopic electrodes and by the pneumatic matrix electrode probe. A 2D or 3D voltage-impedance map of skin is an output of the measuring, interpretation and evaluation process. New pneumatic construction of measuring probe was implemented to achieve a better coverage of specified skin area and get a reduced force range of the touching electrodes allowing the steady contact of the skin-electrode. A skin contact is related to the driving pressure of touching electrodes. Our paper offers experimentally measured results, voltage maps of skin on specific areas, selected measured and described acupuncture points and their applications in electro-acupuncture. |
topic |
acupuncture point driving pressure human skin measuring probe pneumatic electrodes. |
url |
http://advances.utc.sk/index.php/AEEE/article/view/1730 |
work_keys_str_mv |
AT marekkukucka drivingpressureinfluenceinvoltagemapsmeasurementprocessusingadvancedpneumaticmappingprobe AT andreasweisze drivingpressureinfluenceinvoltagemapsmeasurementprocessusingadvancedpneumaticmappingprobe AT danieladurackova drivingpressureinfluenceinvoltagemapsmeasurementprocessusingadvancedpneumaticmappingprobe AT zuzanakrajcuskova drivingpressureinfluenceinvoltagemapsmeasurementprocessusingadvancedpneumaticmappingprobe AT vierastopjakova drivingpressureinfluenceinvoltagemapsmeasurementprocessusingadvancedpneumaticmappingprobe |
_version_ |
1716828088751357952 |