Using The Interaction of Sodium Nitroprusside With Modecate And Tegretol, As an Indirect Method For Their Determination Using S.W.V. Technique

Abstract<br /> A square wave voltammetric (S.W.V.) method has been developed for the quantitative analysis of sodium nitroprusside (SNP), sodium nitroprusside gives a peak at (-0.592) volt against the reference electrode (Ag/AgCl/sat KCl) in phosphate buffer (pH= 7.0). A calibration curve was...

Full description

Bibliographic Details
Main Author: Janan Abdul-Razzak
Format: Article
Language:Arabic
Published: College of Education for Pure Sciences 1999-11-01
Series:مجلة التربية والعلم
Subjects:
Online Access:https://edusj.mosuljournals.com/article_58723_99057f91585e907159afdc265cede8a4.pdf
Description
Summary:Abstract<br /> A square wave voltammetric (S.W.V.) method has been developed for the quantitative analysis of sodium nitroprusside (SNP), sodium nitroprusside gives a peak at (-0.592) volt against the reference electrode (Ag/AgCl/sat KCl) in phosphate buffer (pH= 7.0). A calibration curve was constructed for the range [(0.99 x 10-7-(14.77 x 10-7)]M the method was applied for indirect determination of medicate and tegretol individually via the interaction of SNP with these drugs. So, a calibration curve was constructed by adding appropriate amounts of modecate of the range [(9.84 x 10-11 – 1.360 x 10-9)] M in the presence of (14.77 x 10-6)M SNP. An other calibration curve was constructed by adding appropriate amounts of tegretol of the range [(9.89 x 10-11 – 9.8 x 10-10)] M in the presence of (9.9 x 10-6)M of SNP.
ISSN:1812-125X
2664-2530