Granite stone subjected to ultrasonic fatigue tests under three point bending modality

Ultrasonic fatigue tests are carried out under the modality of three points bending on the granite stone. The testing specimens present a prismatic shape with the dimensions: 12 x 3 x 0.8 centimeters, in order to be supported at the two ends (1 centimeter of support each side), and to configure the...

Full description

Bibliographic Details
Main Authors: Gonzalo Mariano DOMINGUEZ ALMARAZ, Alexiane DOMINGUEZ, Necker J. TRUJILLO ALONSO
Format: Article
Language:English
Published: Gruppo Italiano Frattura 2019-02-01
Series:Frattura ed Integrità Strutturale
Subjects:
Online Access:https://www.fracturae.com/index.php/fis/article/view/2317
id doaj-28775e9dfd3a4d92be251e1f76024911
record_format Article
spelling doaj-28775e9dfd3a4d92be251e1f760249112021-01-27T17:14:18ZengGruppo Italiano FratturaFrattura ed Integrità Strutturale1971-89932019-02-011348Granite stone subjected to ultrasonic fatigue tests under three point bending modalityGonzalo Mariano DOMINGUEZ ALMARAZ0Alexiane DOMINGUEZ1Necker J. TRUJILLO ALONSO2University of MichoacanUniversité Paris-Sud 11, URF Sciences et Techniques, BCSTUniversity of Michoacan (UMSNH) Ultrasonic fatigue tests are carried out under the modality of three points bending on the granite stone. The testing specimens present a prismatic shape with the dimensions: 12 x 3 x 0.8 centimeters, in order to be supported at the two ends (1 centimeter of support each side), and to configure the three points bending modality. Granite specimens are supported on an acrylic structure destined to fix and immobilize the specimens. Vibrating load is applied at the center of testing specimens by a self-designed and fabricated aluminum alloy awl, which dimensions have been obtained by modal numerical analysis to fit the resonance condition, necessary for the ultrasonic fatigue tests. Experimental results are obtained at room temperature and humidity comprised between 60 and 75%. The fatigue endurance is determined on this material under this modality of loading, and the fracture surfaces are analyzed to identify the principal trends related to crack initiation and propagation on this material.    https://www.fracturae.com/index.php/fis/article/view/2317Granite stone:Three point bending:Ultrasonic loading;Fatigue endurance;Fracture surfaces
collection DOAJ
language English
format Article
sources DOAJ
author Gonzalo Mariano DOMINGUEZ ALMARAZ
Alexiane DOMINGUEZ
Necker J. TRUJILLO ALONSO
spellingShingle Gonzalo Mariano DOMINGUEZ ALMARAZ
Alexiane DOMINGUEZ
Necker J. TRUJILLO ALONSO
Granite stone subjected to ultrasonic fatigue tests under three point bending modality
Frattura ed Integrità Strutturale
Granite stone:
Three point bending:
Ultrasonic loading;
Fatigue endurance;
Fracture surfaces
author_facet Gonzalo Mariano DOMINGUEZ ALMARAZ
Alexiane DOMINGUEZ
Necker J. TRUJILLO ALONSO
author_sort Gonzalo Mariano DOMINGUEZ ALMARAZ
title Granite stone subjected to ultrasonic fatigue tests under three point bending modality
title_short Granite stone subjected to ultrasonic fatigue tests under three point bending modality
title_full Granite stone subjected to ultrasonic fatigue tests under three point bending modality
title_fullStr Granite stone subjected to ultrasonic fatigue tests under three point bending modality
title_full_unstemmed Granite stone subjected to ultrasonic fatigue tests under three point bending modality
title_sort granite stone subjected to ultrasonic fatigue tests under three point bending modality
publisher Gruppo Italiano Frattura
series Frattura ed Integrità Strutturale
issn 1971-8993
publishDate 2019-02-01
description Ultrasonic fatigue tests are carried out under the modality of three points bending on the granite stone. The testing specimens present a prismatic shape with the dimensions: 12 x 3 x 0.8 centimeters, in order to be supported at the two ends (1 centimeter of support each side), and to configure the three points bending modality. Granite specimens are supported on an acrylic structure destined to fix and immobilize the specimens. Vibrating load is applied at the center of testing specimens by a self-designed and fabricated aluminum alloy awl, which dimensions have been obtained by modal numerical analysis to fit the resonance condition, necessary for the ultrasonic fatigue tests. Experimental results are obtained at room temperature and humidity comprised between 60 and 75%. The fatigue endurance is determined on this material under this modality of loading, and the fracture surfaces are analyzed to identify the principal trends related to crack initiation and propagation on this material.   
topic Granite stone:
Three point bending:
Ultrasonic loading;
Fatigue endurance;
Fracture surfaces
url https://www.fracturae.com/index.php/fis/article/view/2317
work_keys_str_mv AT gonzalomarianodominguezalmaraz granitestonesubjectedtoultrasonicfatiguetestsunderthreepointbendingmodality
AT alexianedominguez granitestonesubjectedtoultrasonicfatiguetestsunderthreepointbendingmodality
AT neckerjtrujilloalonso granitestonesubjectedtoultrasonicfatiguetestsunderthreepointbendingmodality
_version_ 1724320781535543296