A Stereomicroscopic Evaluation of Dentinal Cracks at Different Instrumentation Lengths by Using Different Rotary Files (ProTaper Universal, ProTaper Next, and HyFlex CM): An Ex Vivo Study

Introduction. The aim of the present study was to evaluate the dentinal cracks after root canal preparation with rotary files: Gates Glidden, ProTaper Universal, ProTaper Next, and HyFlex CM at different instrumentation lengths. Methodology. Sixty-five mandibular premolars were mounted in the acryli...

Full description

Bibliographic Details
Main Authors: Fauzia Ashraf, Pushpa Shankarappa, Abhinav Misra, Asheesh Sawhney, Nandamuri Sridevi, Anu Singh
Format: Article
Language:English
Published: Hindawi Limited 2016-01-01
Series:Scientifica
Online Access:http://dx.doi.org/10.1155/2016/8379865
id doaj-282acffb5b684617b0b4c5bdfb8e923a
record_format Article
spelling doaj-282acffb5b684617b0b4c5bdfb8e923a2020-11-24T21:23:11ZengHindawi LimitedScientifica2090-908X2016-01-01201610.1155/2016/83798658379865A Stereomicroscopic Evaluation of Dentinal Cracks at Different Instrumentation Lengths by Using Different Rotary Files (ProTaper Universal, ProTaper Next, and HyFlex CM): An Ex Vivo StudyFauzia Ashraf0Pushpa Shankarappa1Abhinav Misra2Asheesh Sawhney3Nandamuri Sridevi4Anu Singh5Department of Conservative Dentistry and Endodontics, Rama Dental College, Hospital and Research Centre, Lakhanpur, Kanpur 208024, IndiaDepartment of Conservative Dentistry and Endodontics, Rama Dental College, Hospital and Research Centre, Lakhanpur, Kanpur 208024, IndiaDepartment of Conservative Dentistry and Endodontics, Rama Dental College, Hospital and Research Centre, Lakhanpur, Kanpur 208024, IndiaDepartment of Conservative Dentistry and Endodontics, Rama Dental College, Hospital and Research Centre, Lakhanpur, Kanpur 208024, IndiaDepartment of Conservative Dentistry and Endodontics, Rama Dental College, Hospital and Research Centre, Lakhanpur, Kanpur 208024, IndiaDepartment of Conservative Dentistry and Endodontics, Rama Dental College, Hospital and Research Centre, Lakhanpur, Kanpur 208024, IndiaIntroduction. The aim of the present study was to evaluate the dentinal cracks after root canal preparation with rotary files: Gates Glidden, ProTaper Universal, ProTaper Next, and HyFlex CM at different instrumentation lengths. Methodology. Sixty-five mandibular premolars were mounted in the acrylic tube with simulated periodontal ligaments and the apex was exposed. The root canals were instrumented with different rotary files, namely, ProTaper Universal, ProTaper Next, and HyFlex CM, to the major apical foramen (AF), short AF, and beyond AF. The root apex was stained with 1% methylene blue dye and digital images of apical surface of every tooth were taken and development of dentinal defects was determined by using stereomicroscope. Multinomial logistic regression test was performed to identify influencing factors. Results. Instrumentation with rotary files terminated 2 mm short AF and did not cause any cracks. Significantly less cracks were seen when instrumentation with rotary files terminated 1 mm short apical foramen when compared with the instrumentation terminated at or beyond apical foramen (p<0.05). Conclusion. ProTaper Universal rotary files caused more dentinal cracks than ProTaper Next and HyFlex CM. Instrumentation short AF reduced the risk of dentinal defects.http://dx.doi.org/10.1155/2016/8379865
collection DOAJ
language English
format Article
sources DOAJ
author Fauzia Ashraf
Pushpa Shankarappa
Abhinav Misra
Asheesh Sawhney
Nandamuri Sridevi
Anu Singh
spellingShingle Fauzia Ashraf
Pushpa Shankarappa
Abhinav Misra
Asheesh Sawhney
Nandamuri Sridevi
Anu Singh
A Stereomicroscopic Evaluation of Dentinal Cracks at Different Instrumentation Lengths by Using Different Rotary Files (ProTaper Universal, ProTaper Next, and HyFlex CM): An Ex Vivo Study
Scientifica
author_facet Fauzia Ashraf
Pushpa Shankarappa
Abhinav Misra
Asheesh Sawhney
Nandamuri Sridevi
Anu Singh
author_sort Fauzia Ashraf
title A Stereomicroscopic Evaluation of Dentinal Cracks at Different Instrumentation Lengths by Using Different Rotary Files (ProTaper Universal, ProTaper Next, and HyFlex CM): An Ex Vivo Study
title_short A Stereomicroscopic Evaluation of Dentinal Cracks at Different Instrumentation Lengths by Using Different Rotary Files (ProTaper Universal, ProTaper Next, and HyFlex CM): An Ex Vivo Study
title_full A Stereomicroscopic Evaluation of Dentinal Cracks at Different Instrumentation Lengths by Using Different Rotary Files (ProTaper Universal, ProTaper Next, and HyFlex CM): An Ex Vivo Study
title_fullStr A Stereomicroscopic Evaluation of Dentinal Cracks at Different Instrumentation Lengths by Using Different Rotary Files (ProTaper Universal, ProTaper Next, and HyFlex CM): An Ex Vivo Study
title_full_unstemmed A Stereomicroscopic Evaluation of Dentinal Cracks at Different Instrumentation Lengths by Using Different Rotary Files (ProTaper Universal, ProTaper Next, and HyFlex CM): An Ex Vivo Study
title_sort stereomicroscopic evaluation of dentinal cracks at different instrumentation lengths by using different rotary files (protaper universal, protaper next, and hyflex cm): an ex vivo study
publisher Hindawi Limited
series Scientifica
issn 2090-908X
publishDate 2016-01-01
description Introduction. The aim of the present study was to evaluate the dentinal cracks after root canal preparation with rotary files: Gates Glidden, ProTaper Universal, ProTaper Next, and HyFlex CM at different instrumentation lengths. Methodology. Sixty-five mandibular premolars were mounted in the acrylic tube with simulated periodontal ligaments and the apex was exposed. The root canals were instrumented with different rotary files, namely, ProTaper Universal, ProTaper Next, and HyFlex CM, to the major apical foramen (AF), short AF, and beyond AF. The root apex was stained with 1% methylene blue dye and digital images of apical surface of every tooth were taken and development of dentinal defects was determined by using stereomicroscope. Multinomial logistic regression test was performed to identify influencing factors. Results. Instrumentation with rotary files terminated 2 mm short AF and did not cause any cracks. Significantly less cracks were seen when instrumentation with rotary files terminated 1 mm short apical foramen when compared with the instrumentation terminated at or beyond apical foramen (p<0.05). Conclusion. ProTaper Universal rotary files caused more dentinal cracks than ProTaper Next and HyFlex CM. Instrumentation short AF reduced the risk of dentinal defects.
url http://dx.doi.org/10.1155/2016/8379865
work_keys_str_mv AT fauziaashraf astereomicroscopicevaluationofdentinalcracksatdifferentinstrumentationlengthsbyusingdifferentrotaryfilesprotaperuniversalprotapernextandhyflexcmanexvivostudy
AT pushpashankarappa astereomicroscopicevaluationofdentinalcracksatdifferentinstrumentationlengthsbyusingdifferentrotaryfilesprotaperuniversalprotapernextandhyflexcmanexvivostudy
AT abhinavmisra astereomicroscopicevaluationofdentinalcracksatdifferentinstrumentationlengthsbyusingdifferentrotaryfilesprotaperuniversalprotapernextandhyflexcmanexvivostudy
AT asheeshsawhney astereomicroscopicevaluationofdentinalcracksatdifferentinstrumentationlengthsbyusingdifferentrotaryfilesprotaperuniversalprotapernextandhyflexcmanexvivostudy
AT nandamurisridevi astereomicroscopicevaluationofdentinalcracksatdifferentinstrumentationlengthsbyusingdifferentrotaryfilesprotaperuniversalprotapernextandhyflexcmanexvivostudy
AT anusingh astereomicroscopicevaluationofdentinalcracksatdifferentinstrumentationlengthsbyusingdifferentrotaryfilesprotaperuniversalprotapernextandhyflexcmanexvivostudy
AT fauziaashraf stereomicroscopicevaluationofdentinalcracksatdifferentinstrumentationlengthsbyusingdifferentrotaryfilesprotaperuniversalprotapernextandhyflexcmanexvivostudy
AT pushpashankarappa stereomicroscopicevaluationofdentinalcracksatdifferentinstrumentationlengthsbyusingdifferentrotaryfilesprotaperuniversalprotapernextandhyflexcmanexvivostudy
AT abhinavmisra stereomicroscopicevaluationofdentinalcracksatdifferentinstrumentationlengthsbyusingdifferentrotaryfilesprotaperuniversalprotapernextandhyflexcmanexvivostudy
AT asheeshsawhney stereomicroscopicevaluationofdentinalcracksatdifferentinstrumentationlengthsbyusingdifferentrotaryfilesprotaperuniversalprotapernextandhyflexcmanexvivostudy
AT nandamurisridevi stereomicroscopicevaluationofdentinalcracksatdifferentinstrumentationlengthsbyusingdifferentrotaryfilesprotaperuniversalprotapernextandhyflexcmanexvivostudy
AT anusingh stereomicroscopicevaluationofdentinalcracksatdifferentinstrumentationlengthsbyusingdifferentrotaryfilesprotaperuniversalprotapernextandhyflexcmanexvivostudy
_version_ 1725993177426427904