Calibration of a FDS-LC long counter for monitoring the neutron fluence at the HINEG facility
A FDS-LC long counter was developed to monitor the neutron fluence at the HINEG facility. The response function and the effective centre of long counter were calculated by using SuperMC code. The calibration of this long counter was performed in Research Facility, China institute of atomic energy. T...
Main Authors: | , , , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
EDP Sciences
2017-01-01
|
Series: | EPJ Web of Conferences |
Subjects: | |
Online Access: | https://doi.org/10.1051/epjconf/201715301015 |
id |
doaj-27d59e8b222f4b69be26c2a91ad5bb51 |
---|---|
record_format |
Article |
spelling |
doaj-27d59e8b222f4b69be26c2a91ad5bb512021-08-02T04:56:42ZengEDP SciencesEPJ Web of Conferences2100-014X2017-01-011530101510.1051/epjconf/201715301015epjconf_icrs2017_01015Calibration of a FDS-LC long counter for monitoring the neutron fluence at the HINEG facilityHong BingLi YananMazuga MohamedLi TaoshengWang YongfengJi XiangLiu ChaoJiang JieqiongA FDS-LC long counter was developed to monitor the neutron fluence at the HINEG facility. The response function and the effective centre of long counter were calculated by using SuperMC code. The calibration of this long counter was performed in Research Facility, China institute of atomic energy. The results of experimental and simulative characterization of the FDS-LC long counter are persented in this paper. The comparison of the measured results with the calculated results shown a good agreement within 5%.https://doi.org/10.1051/epjconf/201715301015Long counterResponseThe effective centreCalibration |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Hong Bing Li Yanan Mazuga Mohamed Li Taosheng Wang Yongfeng Ji Xiang Liu Chao Jiang Jieqiong |
spellingShingle |
Hong Bing Li Yanan Mazuga Mohamed Li Taosheng Wang Yongfeng Ji Xiang Liu Chao Jiang Jieqiong Calibration of a FDS-LC long counter for monitoring the neutron fluence at the HINEG facility EPJ Web of Conferences Long counter Response The effective centre Calibration |
author_facet |
Hong Bing Li Yanan Mazuga Mohamed Li Taosheng Wang Yongfeng Ji Xiang Liu Chao Jiang Jieqiong |
author_sort |
Hong Bing |
title |
Calibration of a FDS-LC long counter for monitoring the neutron fluence at the HINEG facility |
title_short |
Calibration of a FDS-LC long counter for monitoring the neutron fluence at the HINEG facility |
title_full |
Calibration of a FDS-LC long counter for monitoring the neutron fluence at the HINEG facility |
title_fullStr |
Calibration of a FDS-LC long counter for monitoring the neutron fluence at the HINEG facility |
title_full_unstemmed |
Calibration of a FDS-LC long counter for monitoring the neutron fluence at the HINEG facility |
title_sort |
calibration of a fds-lc long counter for monitoring the neutron fluence at the hineg facility |
publisher |
EDP Sciences |
series |
EPJ Web of Conferences |
issn |
2100-014X |
publishDate |
2017-01-01 |
description |
A FDS-LC long counter was developed to monitor the neutron fluence at the HINEG facility. The response function and the effective centre of long counter were calculated by using SuperMC code. The calibration of this long counter was performed in Research Facility, China institute of atomic energy. The results of experimental and simulative characterization of the FDS-LC long counter are persented in this paper. The comparison of the measured results with the calculated results shown a good agreement within 5%. |
topic |
Long counter Response The effective centre Calibration |
url |
https://doi.org/10.1051/epjconf/201715301015 |
work_keys_str_mv |
AT hongbing calibrationofafdslclongcounterformonitoringtheneutronfluenceatthehinegfacility AT liyanan calibrationofafdslclongcounterformonitoringtheneutronfluenceatthehinegfacility AT mazugamohamed calibrationofafdslclongcounterformonitoringtheneutronfluenceatthehinegfacility AT litaosheng calibrationofafdslclongcounterformonitoringtheneutronfluenceatthehinegfacility AT wangyongfeng calibrationofafdslclongcounterformonitoringtheneutronfluenceatthehinegfacility AT jixiang calibrationofafdslclongcounterformonitoringtheneutronfluenceatthehinegfacility AT liuchao calibrationofafdslclongcounterformonitoringtheneutronfluenceatthehinegfacility AT jiangjieqiong calibrationofafdslclongcounterformonitoringtheneutronfluenceatthehinegfacility |
_version_ |
1721241786875117568 |