Effect of Liquid Injection Arrangements on Injection Flow Rate of a Laboratory-Scale Venturi Scrubber
As the core device of a filtered containment venting system (FCVS), Venturi Scrubber is an efficient device to scrub the radioactive gases and aerosols before release into the atmosphere. The design concept of Multi-Venturi Scrubber System makes the laboratory-scale venturi scrubber research more va...
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Frontiers Media S.A.
2019-06-01
|
Series: | Frontiers in Energy Research |
Subjects: | |
Online Access: | https://www.frontiersin.org/article/10.3389/fenrg.2019.00051/full |
id |
doaj-27c424b1834e4fa9a8a2ef2f40e76dd1 |
---|---|
record_format |
Article |
spelling |
doaj-27c424b1834e4fa9a8a2ef2f40e76dd12020-11-25T00:52:58ZengFrontiers Media S.A.Frontiers in Energy Research2296-598X2019-06-01710.3389/fenrg.2019.00051439136Effect of Liquid Injection Arrangements on Injection Flow Rate of a Laboratory-Scale Venturi ScrubberGuangzong Zheng0Guangzong Zheng1Bo Chen2Jishen Li3Kaiyi Shi4Haifeng Gu5Fundamental Science on Nuclear Safety and Simulation Technology Laboratory, Harbin Engineering University, Harbin, ChinaChina Institute of Atomic Energy, Beijing, ChinaChina Nuclear Power Engineering Co., Ltd., Beijing, ChinaFundamental Science on Nuclear Safety and Simulation Technology Laboratory, Harbin Engineering University, Harbin, ChinaDepartment of Chemistry and Chemical Engineering, LiuPanshui Normal University, LiuPanshui, ChinaFundamental Science on Nuclear Safety and Simulation Technology Laboratory, Harbin Engineering University, Harbin, ChinaAs the core device of a filtered containment venting system (FCVS), Venturi Scrubber is an efficient device to scrub the radioactive gases and aerosols before release into the atmosphere. The design concept of Multi-Venturi Scrubber System makes the laboratory-scale venturi scrubber research more valuable. This paper studied the injection flow rate of Venturi Scrubber in different injection arrangements. The liquid is injected horizontally and vertically to the throat at different radial position of (i) at the wall of throat, (ii) at the half radius of throat, and (iii) at the center of Venturi Scrubber throat with a nozzle of diameter 4 mm. Throat gas velocities range from 0 to 190 m/s. A constant level water tank was installed to keep water level constant during the injection process. The results showed that liquid injection modes significantly affect the injection performance. The arrangements of straight tube at center and elbow tube at center had larger injection flow rate among the others, and the injection flow rate increased as the throat gas velocity increased. The conventional wall opening (i.e., straight tube at the wall) injection method had the worst injection performance. This study provides a valuable reference for the liquid injection arrangement and structural design of the Venturi Scrubber.https://www.frontiersin.org/article/10.3389/fenrg.2019.00051/fullVenturi Scrubberinjection arrangementinjection flow ratefiltered containment venting systemFCVS |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Guangzong Zheng Guangzong Zheng Bo Chen Jishen Li Kaiyi Shi Haifeng Gu |
spellingShingle |
Guangzong Zheng Guangzong Zheng Bo Chen Jishen Li Kaiyi Shi Haifeng Gu Effect of Liquid Injection Arrangements on Injection Flow Rate of a Laboratory-Scale Venturi Scrubber Frontiers in Energy Research Venturi Scrubber injection arrangement injection flow rate filtered containment venting system FCVS |
author_facet |
Guangzong Zheng Guangzong Zheng Bo Chen Jishen Li Kaiyi Shi Haifeng Gu |
author_sort |
Guangzong Zheng |
title |
Effect of Liquid Injection Arrangements on Injection Flow Rate of a Laboratory-Scale Venturi Scrubber |
title_short |
Effect of Liquid Injection Arrangements on Injection Flow Rate of a Laboratory-Scale Venturi Scrubber |
title_full |
Effect of Liquid Injection Arrangements on Injection Flow Rate of a Laboratory-Scale Venturi Scrubber |
title_fullStr |
Effect of Liquid Injection Arrangements on Injection Flow Rate of a Laboratory-Scale Venturi Scrubber |
title_full_unstemmed |
Effect of Liquid Injection Arrangements on Injection Flow Rate of a Laboratory-Scale Venturi Scrubber |
title_sort |
effect of liquid injection arrangements on injection flow rate of a laboratory-scale venturi scrubber |
publisher |
Frontiers Media S.A. |
series |
Frontiers in Energy Research |
issn |
2296-598X |
publishDate |
2019-06-01 |
description |
As the core device of a filtered containment venting system (FCVS), Venturi Scrubber is an efficient device to scrub the radioactive gases and aerosols before release into the atmosphere. The design concept of Multi-Venturi Scrubber System makes the laboratory-scale venturi scrubber research more valuable. This paper studied the injection flow rate of Venturi Scrubber in different injection arrangements. The liquid is injected horizontally and vertically to the throat at different radial position of (i) at the wall of throat, (ii) at the half radius of throat, and (iii) at the center of Venturi Scrubber throat with a nozzle of diameter 4 mm. Throat gas velocities range from 0 to 190 m/s. A constant level water tank was installed to keep water level constant during the injection process. The results showed that liquid injection modes significantly affect the injection performance. The arrangements of straight tube at center and elbow tube at center had larger injection flow rate among the others, and the injection flow rate increased as the throat gas velocity increased. The conventional wall opening (i.e., straight tube at the wall) injection method had the worst injection performance. This study provides a valuable reference for the liquid injection arrangement and structural design of the Venturi Scrubber. |
topic |
Venturi Scrubber injection arrangement injection flow rate filtered containment venting system FCVS |
url |
https://www.frontiersin.org/article/10.3389/fenrg.2019.00051/full |
work_keys_str_mv |
AT guangzongzheng effectofliquidinjectionarrangementsoninjectionflowrateofalaboratoryscaleventuriscrubber AT guangzongzheng effectofliquidinjectionarrangementsoninjectionflowrateofalaboratoryscaleventuriscrubber AT bochen effectofliquidinjectionarrangementsoninjectionflowrateofalaboratoryscaleventuriscrubber AT jishenli effectofliquidinjectionarrangementsoninjectionflowrateofalaboratoryscaleventuriscrubber AT kaiyishi effectofliquidinjectionarrangementsoninjectionflowrateofalaboratoryscaleventuriscrubber AT haifenggu effectofliquidinjectionarrangementsoninjectionflowrateofalaboratoryscaleventuriscrubber |
_version_ |
1725239907223339008 |