Effect of Liquid Injection Arrangements on Injection Flow Rate of a Laboratory-Scale Venturi Scrubber

As the core device of a filtered containment venting system (FCVS), Venturi Scrubber is an efficient device to scrub the radioactive gases and aerosols before release into the atmosphere. The design concept of Multi-Venturi Scrubber System makes the laboratory-scale venturi scrubber research more va...

Full description

Bibliographic Details
Main Authors: Guangzong Zheng, Bo Chen, Jishen Li, Kaiyi Shi, Haifeng Gu
Format: Article
Language:English
Published: Frontiers Media S.A. 2019-06-01
Series:Frontiers in Energy Research
Subjects:
Online Access:https://www.frontiersin.org/article/10.3389/fenrg.2019.00051/full
id doaj-27c424b1834e4fa9a8a2ef2f40e76dd1
record_format Article
spelling doaj-27c424b1834e4fa9a8a2ef2f40e76dd12020-11-25T00:52:58ZengFrontiers Media S.A.Frontiers in Energy Research2296-598X2019-06-01710.3389/fenrg.2019.00051439136Effect of Liquid Injection Arrangements on Injection Flow Rate of a Laboratory-Scale Venturi ScrubberGuangzong Zheng0Guangzong Zheng1Bo Chen2Jishen Li3Kaiyi Shi4Haifeng Gu5Fundamental Science on Nuclear Safety and Simulation Technology Laboratory, Harbin Engineering University, Harbin, ChinaChina Institute of Atomic Energy, Beijing, ChinaChina Nuclear Power Engineering Co., Ltd., Beijing, ChinaFundamental Science on Nuclear Safety and Simulation Technology Laboratory, Harbin Engineering University, Harbin, ChinaDepartment of Chemistry and Chemical Engineering, LiuPanshui Normal University, LiuPanshui, ChinaFundamental Science on Nuclear Safety and Simulation Technology Laboratory, Harbin Engineering University, Harbin, ChinaAs the core device of a filtered containment venting system (FCVS), Venturi Scrubber is an efficient device to scrub the radioactive gases and aerosols before release into the atmosphere. The design concept of Multi-Venturi Scrubber System makes the laboratory-scale venturi scrubber research more valuable. This paper studied the injection flow rate of Venturi Scrubber in different injection arrangements. The liquid is injected horizontally and vertically to the throat at different radial position of (i) at the wall of throat, (ii) at the half radius of throat, and (iii) at the center of Venturi Scrubber throat with a nozzle of diameter 4 mm. Throat gas velocities range from 0 to 190 m/s. A constant level water tank was installed to keep water level constant during the injection process. The results showed that liquid injection modes significantly affect the injection performance. The arrangements of straight tube at center and elbow tube at center had larger injection flow rate among the others, and the injection flow rate increased as the throat gas velocity increased. The conventional wall opening (i.e., straight tube at the wall) injection method had the worst injection performance. This study provides a valuable reference for the liquid injection arrangement and structural design of the Venturi Scrubber.https://www.frontiersin.org/article/10.3389/fenrg.2019.00051/fullVenturi Scrubberinjection arrangementinjection flow ratefiltered containment venting systemFCVS
collection DOAJ
language English
format Article
sources DOAJ
author Guangzong Zheng
Guangzong Zheng
Bo Chen
Jishen Li
Kaiyi Shi
Haifeng Gu
spellingShingle Guangzong Zheng
Guangzong Zheng
Bo Chen
Jishen Li
Kaiyi Shi
Haifeng Gu
Effect of Liquid Injection Arrangements on Injection Flow Rate of a Laboratory-Scale Venturi Scrubber
Frontiers in Energy Research
Venturi Scrubber
injection arrangement
injection flow rate
filtered containment venting system
FCVS
author_facet Guangzong Zheng
Guangzong Zheng
Bo Chen
Jishen Li
Kaiyi Shi
Haifeng Gu
author_sort Guangzong Zheng
title Effect of Liquid Injection Arrangements on Injection Flow Rate of a Laboratory-Scale Venturi Scrubber
title_short Effect of Liquid Injection Arrangements on Injection Flow Rate of a Laboratory-Scale Venturi Scrubber
title_full Effect of Liquid Injection Arrangements on Injection Flow Rate of a Laboratory-Scale Venturi Scrubber
title_fullStr Effect of Liquid Injection Arrangements on Injection Flow Rate of a Laboratory-Scale Venturi Scrubber
title_full_unstemmed Effect of Liquid Injection Arrangements on Injection Flow Rate of a Laboratory-Scale Venturi Scrubber
title_sort effect of liquid injection arrangements on injection flow rate of a laboratory-scale venturi scrubber
publisher Frontiers Media S.A.
series Frontiers in Energy Research
issn 2296-598X
publishDate 2019-06-01
description As the core device of a filtered containment venting system (FCVS), Venturi Scrubber is an efficient device to scrub the radioactive gases and aerosols before release into the atmosphere. The design concept of Multi-Venturi Scrubber System makes the laboratory-scale venturi scrubber research more valuable. This paper studied the injection flow rate of Venturi Scrubber in different injection arrangements. The liquid is injected horizontally and vertically to the throat at different radial position of (i) at the wall of throat, (ii) at the half radius of throat, and (iii) at the center of Venturi Scrubber throat with a nozzle of diameter 4 mm. Throat gas velocities range from 0 to 190 m/s. A constant level water tank was installed to keep water level constant during the injection process. The results showed that liquid injection modes significantly affect the injection performance. The arrangements of straight tube at center and elbow tube at center had larger injection flow rate among the others, and the injection flow rate increased as the throat gas velocity increased. The conventional wall opening (i.e., straight tube at the wall) injection method had the worst injection performance. This study provides a valuable reference for the liquid injection arrangement and structural design of the Venturi Scrubber.
topic Venturi Scrubber
injection arrangement
injection flow rate
filtered containment venting system
FCVS
url https://www.frontiersin.org/article/10.3389/fenrg.2019.00051/full
work_keys_str_mv AT guangzongzheng effectofliquidinjectionarrangementsoninjectionflowrateofalaboratoryscaleventuriscrubber
AT guangzongzheng effectofliquidinjectionarrangementsoninjectionflowrateofalaboratoryscaleventuriscrubber
AT bochen effectofliquidinjectionarrangementsoninjectionflowrateofalaboratoryscaleventuriscrubber
AT jishenli effectofliquidinjectionarrangementsoninjectionflowrateofalaboratoryscaleventuriscrubber
AT kaiyishi effectofliquidinjectionarrangementsoninjectionflowrateofalaboratoryscaleventuriscrubber
AT haifenggu effectofliquidinjectionarrangementsoninjectionflowrateofalaboratoryscaleventuriscrubber
_version_ 1725239907223339008