Differential Sensor for PH Monitoring of Environmental Objects
Differential pH sensor is proposed. Reference electrode and measuring electrode are the same type. Reference electrode is immersed in standard buffer solution with known pH value. The differential pH sensor has longer service life as compared with the traditionally used sensors with silver chloride...
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
EDP Sciences
2016-01-01
|
Series: | MATEC Web of Conferences |
Online Access: | http://dx.doi.org/10.1051/matecconf/20167901008 |
id |
doaj-2780fe79de5f4f9d8f2ab945b90b4c73 |
---|---|
record_format |
Article |
spelling |
doaj-2780fe79de5f4f9d8f2ab945b90b4c732021-02-02T01:25:34ZengEDP SciencesMATEC Web of Conferences2261-236X2016-01-01790100810.1051/matecconf/20167901008matecconf_imet2016_01008Differential Sensor for PH Monitoring of Environmental ObjectsRomanenko SergeyRadenkov TimofeyNewsky EgorKagirov ArturDifferential pH sensor is proposed. Reference electrode and measuring electrode are the same type. Reference electrode is immersed in standard buffer solution with known pH value. The differential pH sensor has longer service life as compared with the traditionally used sensors with silver chloride reference electrode. Ultrasonic cleaning system is proposed to clean the primary measuring transducer from pollution that form as result of silting during long-term operation with the sensor.http://dx.doi.org/10.1051/matecconf/20167901008 |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Romanenko Sergey Radenkov Timofey Newsky Egor Kagirov Artur |
spellingShingle |
Romanenko Sergey Radenkov Timofey Newsky Egor Kagirov Artur Differential Sensor for PH Monitoring of Environmental Objects MATEC Web of Conferences |
author_facet |
Romanenko Sergey Radenkov Timofey Newsky Egor Kagirov Artur |
author_sort |
Romanenko Sergey |
title |
Differential Sensor for PH Monitoring of Environmental Objects |
title_short |
Differential Sensor for PH Monitoring of Environmental Objects |
title_full |
Differential Sensor for PH Monitoring of Environmental Objects |
title_fullStr |
Differential Sensor for PH Monitoring of Environmental Objects |
title_full_unstemmed |
Differential Sensor for PH Monitoring of Environmental Objects |
title_sort |
differential sensor for ph monitoring of environmental objects |
publisher |
EDP Sciences |
series |
MATEC Web of Conferences |
issn |
2261-236X |
publishDate |
2016-01-01 |
description |
Differential pH sensor is proposed. Reference electrode and measuring electrode are the same type. Reference electrode is immersed in standard buffer solution with known pH value. The differential pH sensor has longer service life as compared with the traditionally used sensors with silver chloride reference electrode. Ultrasonic cleaning system is proposed to clean the primary measuring transducer from pollution that form as result of silting during long-term operation with the sensor. |
url |
http://dx.doi.org/10.1051/matecconf/20167901008 |
work_keys_str_mv |
AT romanenkosergey differentialsensorforphmonitoringofenvironmentalobjects AT radenkovtimofey differentialsensorforphmonitoringofenvironmentalobjects AT newskyegor differentialsensorforphmonitoringofenvironmentalobjects AT kagirovartur differentialsensorforphmonitoringofenvironmentalobjects |
_version_ |
1724311785963520000 |