Overall precision test of near infrared spectroscopy on mango fruits (Mangifera indica CV. ‘Nam Dok Mai Si Thong’) by on-line and off-line systems

The near infrared (NIR) spectroscopy both on-line and off-line scanning was applied on mango fruits (Mangifera indica CV. ‘Nam dok mai- si Thong’) for the overall precision test. The reference parameter was total soluble solids content (Brix value). The results showed that the off-line scanning had...

Full description

Bibliographic Details
Main Authors: Lekhawattana Wachiraya, Sirisomboon Panmanas
Format: Article
Language:English
Published: EDP Sciences 2020-01-01
Series:E3S Web of Conferences
Online Access:https://www.e3s-conferences.org/articles/e3sconf/pdf/2020/47/e3sconf_tsae2020_04006.pdf
id doaj-275e97ed87e144d2a60b4f61347ef7d6
record_format Article
spelling doaj-275e97ed87e144d2a60b4f61347ef7d62021-04-02T09:25:48ZengEDP SciencesE3S Web of Conferences2267-12422020-01-011870400610.1051/e3sconf/202018704006e3sconf_tsae2020_04006Overall precision test of near infrared spectroscopy on mango fruits (Mangifera indica CV. ‘Nam Dok Mai Si Thong’) by on-line and off-line systemsLekhawattana Wachiraya0Sirisomboon Panmanas1King Mongkut’s Institute of Technology Ladkrabang, Department of Agricultural Engineering, Faculty of EngineeringKing Mongkut’s Institute of Technology Ladkrabang, NIR Spectroscopy Research Center for Agricultural Products and Foods, Department of Agricultural Engineering, Faculty of EngineeringThe near infrared (NIR) spectroscopy both on-line and off-line scanning was applied on mango fruits (Mangifera indica CV. ‘Nam dok mai- si Thong’) for the overall precision test. The reference parameter was total soluble solids content (Brix value). The results showed that the off-line scanning had a higher accuracy than on-line scanning. The scanning repeatability of the off-line and on-line systems were 0.00199 and 0.00993, respectively. The scanning reproducibility of the off-line and online systems were 0.00279 and 0.00513, respectively. The reference of measurement repeatability was 0.2. The maximum coefficient of determination (R2max) of the reference measurement was 0.894.https://www.e3s-conferences.org/articles/e3sconf/pdf/2020/47/e3sconf_tsae2020_04006.pdf
collection DOAJ
language English
format Article
sources DOAJ
author Lekhawattana Wachiraya
Sirisomboon Panmanas
spellingShingle Lekhawattana Wachiraya
Sirisomboon Panmanas
Overall precision test of near infrared spectroscopy on mango fruits (Mangifera indica CV. ‘Nam Dok Mai Si Thong’) by on-line and off-line systems
E3S Web of Conferences
author_facet Lekhawattana Wachiraya
Sirisomboon Panmanas
author_sort Lekhawattana Wachiraya
title Overall precision test of near infrared spectroscopy on mango fruits (Mangifera indica CV. ‘Nam Dok Mai Si Thong’) by on-line and off-line systems
title_short Overall precision test of near infrared spectroscopy on mango fruits (Mangifera indica CV. ‘Nam Dok Mai Si Thong’) by on-line and off-line systems
title_full Overall precision test of near infrared spectroscopy on mango fruits (Mangifera indica CV. ‘Nam Dok Mai Si Thong’) by on-line and off-line systems
title_fullStr Overall precision test of near infrared spectroscopy on mango fruits (Mangifera indica CV. ‘Nam Dok Mai Si Thong’) by on-line and off-line systems
title_full_unstemmed Overall precision test of near infrared spectroscopy on mango fruits (Mangifera indica CV. ‘Nam Dok Mai Si Thong’) by on-line and off-line systems
title_sort overall precision test of near infrared spectroscopy on mango fruits (mangifera indica cv. ‘nam dok mai si thong’) by on-line and off-line systems
publisher EDP Sciences
series E3S Web of Conferences
issn 2267-1242
publishDate 2020-01-01
description The near infrared (NIR) spectroscopy both on-line and off-line scanning was applied on mango fruits (Mangifera indica CV. ‘Nam dok mai- si Thong’) for the overall precision test. The reference parameter was total soluble solids content (Brix value). The results showed that the off-line scanning had a higher accuracy than on-line scanning. The scanning repeatability of the off-line and on-line systems were 0.00199 and 0.00993, respectively. The scanning reproducibility of the off-line and online systems were 0.00279 and 0.00513, respectively. The reference of measurement repeatability was 0.2. The maximum coefficient of determination (R2max) of the reference measurement was 0.894.
url https://www.e3s-conferences.org/articles/e3sconf/pdf/2020/47/e3sconf_tsae2020_04006.pdf
work_keys_str_mv AT lekhawattanawachiraya overallprecisiontestofnearinfraredspectroscopyonmangofruitsmangiferaindicacvnamdokmaisithongbyonlineandofflinesystems
AT sirisomboonpanmanas overallprecisiontestofnearinfraredspectroscopyonmangofruitsmangiferaindicacvnamdokmaisithongbyonlineandofflinesystems
_version_ 1724169393193091072