Overall precision test of near infrared spectroscopy on mango fruits (Mangifera indica CV. ‘Nam Dok Mai Si Thong’) by on-line and off-line systems
The near infrared (NIR) spectroscopy both on-line and off-line scanning was applied on mango fruits (Mangifera indica CV. ‘Nam dok mai- si Thong’) for the overall precision test. The reference parameter was total soluble solids content (Brix value). The results showed that the off-line scanning had...
Main Authors: | , |
---|---|
Format: | Article |
Language: | English |
Published: |
EDP Sciences
2020-01-01
|
Series: | E3S Web of Conferences |
Online Access: | https://www.e3s-conferences.org/articles/e3sconf/pdf/2020/47/e3sconf_tsae2020_04006.pdf |
Summary: | The near infrared (NIR) spectroscopy both on-line and off-line scanning was applied on mango fruits (Mangifera indica CV. ‘Nam dok mai- si Thong’) for the overall precision test. The reference parameter was total soluble solids content (Brix value). The results showed that the off-line scanning had a higher accuracy than on-line scanning. The scanning repeatability of the off-line and on-line systems were 0.00199 and 0.00993, respectively. The scanning reproducibility of the off-line and online systems were 0.00279 and 0.00513, respectively. The reference of measurement repeatability was 0.2. The maximum coefficient of determination (R2max) of the reference measurement was 0.894. |
---|---|
ISSN: | 2267-1242 |