A fibre-reinforced poroviscoelastic model accurately describes the biomechanical behaviour of the rat Achilles tendon.

Computational models of Achilles tendons can help understanding how healthy tendons are affected by repetitive loading and how the different tissue constituents contribute to the tendon's biomechanical response. However, available models of Achilles tendon are limited in their description of th...

Full description

Bibliographic Details
Main Authors: Hanifeh Khayyeri, Anna Gustafsson, Ashley Heuijerjans, Marko K Matikainen, Petro Julkunen, Pernilla Eliasson, Per Aspenberg, Hanna Isaksson
Format: Article
Language:English
Published: Public Library of Science (PLoS) 2015-01-01
Series:PLoS ONE
Online Access:http://europepmc.org/articles/PMC4450879?pdf=render
id doaj-2659ddfeeeba431ab245dcf136b701aa
record_format Article
spelling doaj-2659ddfeeeba431ab245dcf136b701aa2020-11-25T02:47:11ZengPublic Library of Science (PLoS)PLoS ONE1932-62032015-01-01106e012686910.1371/journal.pone.0126869A fibre-reinforced poroviscoelastic model accurately describes the biomechanical behaviour of the rat Achilles tendon.Hanifeh KhayyeriAnna GustafssonAshley HeuijerjansMarko K MatikainenPetro JulkunenPernilla EliassonPer AspenbergHanna IsakssonComputational models of Achilles tendons can help understanding how healthy tendons are affected by repetitive loading and how the different tissue constituents contribute to the tendon's biomechanical response. However, available models of Achilles tendon are limited in their description of the hierarchical multi-structural composition of the tissue. This study hypothesised that a poroviscoelastic fibre-reinforced model, previously successful in capturing cartilage biomechanical behaviour, can depict the biomechanical behaviour of the rat Achilles tendon found experimentally.We developed a new material model of the Achilles tendon, which considers the tendon's main constituents namely: water, proteoglycan matrix and collagen fibres. A hyperelastic formulation of the proteoglycan matrix enabled computations of large deformations of the tendon, and collagen fibres were modelled as viscoelastic. Specimen-specific finite element models were created of 9 rat Achilles tendons from an animal experiment and simulations were carried out following a repetitive tensile loading protocol. The material model parameters were calibrated against data from the rats by minimising the root mean squared error (RMS) between experimental force data and model output.All specimen models were successfully fitted to experimental data with high accuracy (RMS 0.42-1.02). Additional simulations predicted more compliant and soft tendon behaviour at reduced strain-rates compared to higher strain-rates that produce a stiff and brittle tendon response. Stress-relaxation simulations exhibited strain-dependent stress-relaxation behaviour where larger strains produced slower relaxation rates compared to smaller strain levels. Our simulations showed that the collagen fibres in the Achilles tendon are the main load-bearing component during tensile loading, where the orientation of the collagen fibres plays an important role for the tendon's viscoelastic response. In conclusion, this model can capture the repetitive loading and unloading behaviour of intact and healthy Achilles tendons, which is a critical first step towards understanding tendon homeostasis and function as this biomechanical response changes in diseased tendons.http://europepmc.org/articles/PMC4450879?pdf=render
collection DOAJ
language English
format Article
sources DOAJ
author Hanifeh Khayyeri
Anna Gustafsson
Ashley Heuijerjans
Marko K Matikainen
Petro Julkunen
Pernilla Eliasson
Per Aspenberg
Hanna Isaksson
spellingShingle Hanifeh Khayyeri
Anna Gustafsson
Ashley Heuijerjans
Marko K Matikainen
Petro Julkunen
Pernilla Eliasson
Per Aspenberg
Hanna Isaksson
A fibre-reinforced poroviscoelastic model accurately describes the biomechanical behaviour of the rat Achilles tendon.
PLoS ONE
author_facet Hanifeh Khayyeri
Anna Gustafsson
Ashley Heuijerjans
Marko K Matikainen
Petro Julkunen
Pernilla Eliasson
Per Aspenberg
Hanna Isaksson
author_sort Hanifeh Khayyeri
title A fibre-reinforced poroviscoelastic model accurately describes the biomechanical behaviour of the rat Achilles tendon.
title_short A fibre-reinforced poroviscoelastic model accurately describes the biomechanical behaviour of the rat Achilles tendon.
title_full A fibre-reinforced poroviscoelastic model accurately describes the biomechanical behaviour of the rat Achilles tendon.
title_fullStr A fibre-reinforced poroviscoelastic model accurately describes the biomechanical behaviour of the rat Achilles tendon.
title_full_unstemmed A fibre-reinforced poroviscoelastic model accurately describes the biomechanical behaviour of the rat Achilles tendon.
title_sort fibre-reinforced poroviscoelastic model accurately describes the biomechanical behaviour of the rat achilles tendon.
publisher Public Library of Science (PLoS)
series PLoS ONE
issn 1932-6203
publishDate 2015-01-01
description Computational models of Achilles tendons can help understanding how healthy tendons are affected by repetitive loading and how the different tissue constituents contribute to the tendon's biomechanical response. However, available models of Achilles tendon are limited in their description of the hierarchical multi-structural composition of the tissue. This study hypothesised that a poroviscoelastic fibre-reinforced model, previously successful in capturing cartilage biomechanical behaviour, can depict the biomechanical behaviour of the rat Achilles tendon found experimentally.We developed a new material model of the Achilles tendon, which considers the tendon's main constituents namely: water, proteoglycan matrix and collagen fibres. A hyperelastic formulation of the proteoglycan matrix enabled computations of large deformations of the tendon, and collagen fibres were modelled as viscoelastic. Specimen-specific finite element models were created of 9 rat Achilles tendons from an animal experiment and simulations were carried out following a repetitive tensile loading protocol. The material model parameters were calibrated against data from the rats by minimising the root mean squared error (RMS) between experimental force data and model output.All specimen models were successfully fitted to experimental data with high accuracy (RMS 0.42-1.02). Additional simulations predicted more compliant and soft tendon behaviour at reduced strain-rates compared to higher strain-rates that produce a stiff and brittle tendon response. Stress-relaxation simulations exhibited strain-dependent stress-relaxation behaviour where larger strains produced slower relaxation rates compared to smaller strain levels. Our simulations showed that the collagen fibres in the Achilles tendon are the main load-bearing component during tensile loading, where the orientation of the collagen fibres plays an important role for the tendon's viscoelastic response. In conclusion, this model can capture the repetitive loading and unloading behaviour of intact and healthy Achilles tendons, which is a critical first step towards understanding tendon homeostasis and function as this biomechanical response changes in diseased tendons.
url http://europepmc.org/articles/PMC4450879?pdf=render
work_keys_str_mv AT hanifehkhayyeri afibrereinforcedporoviscoelasticmodelaccuratelydescribesthebiomechanicalbehaviouroftheratachillestendon
AT annagustafsson afibrereinforcedporoviscoelasticmodelaccuratelydescribesthebiomechanicalbehaviouroftheratachillestendon
AT ashleyheuijerjans afibrereinforcedporoviscoelasticmodelaccuratelydescribesthebiomechanicalbehaviouroftheratachillestendon
AT markokmatikainen afibrereinforcedporoviscoelasticmodelaccuratelydescribesthebiomechanicalbehaviouroftheratachillestendon
AT petrojulkunen afibrereinforcedporoviscoelasticmodelaccuratelydescribesthebiomechanicalbehaviouroftheratachillestendon
AT pernillaeliasson afibrereinforcedporoviscoelasticmodelaccuratelydescribesthebiomechanicalbehaviouroftheratachillestendon
AT peraspenberg afibrereinforcedporoviscoelasticmodelaccuratelydescribesthebiomechanicalbehaviouroftheratachillestendon
AT hannaisaksson afibrereinforcedporoviscoelasticmodelaccuratelydescribesthebiomechanicalbehaviouroftheratachillestendon
AT hanifehkhayyeri fibrereinforcedporoviscoelasticmodelaccuratelydescribesthebiomechanicalbehaviouroftheratachillestendon
AT annagustafsson fibrereinforcedporoviscoelasticmodelaccuratelydescribesthebiomechanicalbehaviouroftheratachillestendon
AT ashleyheuijerjans fibrereinforcedporoviscoelasticmodelaccuratelydescribesthebiomechanicalbehaviouroftheratachillestendon
AT markokmatikainen fibrereinforcedporoviscoelasticmodelaccuratelydescribesthebiomechanicalbehaviouroftheratachillestendon
AT petrojulkunen fibrereinforcedporoviscoelasticmodelaccuratelydescribesthebiomechanicalbehaviouroftheratachillestendon
AT pernillaeliasson fibrereinforcedporoviscoelasticmodelaccuratelydescribesthebiomechanicalbehaviouroftheratachillestendon
AT peraspenberg fibrereinforcedporoviscoelasticmodelaccuratelydescribesthebiomechanicalbehaviouroftheratachillestendon
AT hannaisaksson fibrereinforcedporoviscoelasticmodelaccuratelydescribesthebiomechanicalbehaviouroftheratachillestendon
_version_ 1724754019244572672