Shaping and Centering Ability, Cyclic Fatigue Resistance and Fractographic Analysis of Three Thermally Treated NiTi Endodontic Instrument Systems

The better understanding of the clinically important behavioral features of new instrument systems has an important significance for the clinical endodontics. This study aimed to investigate the shaping and centering ability as well as cyclic fatigue resistance of HyFlex CM (CM), HyFlex EDM (EDM) an...

Full description

Bibliographic Details
Main Authors: Saulius Drukteinis, Vytaute Peciuliene, Ruta Bendinskaite, Vilma Brukiene, Rasmute Maneliene, Vygandas Rutkunas
Format: Article
Language:English
Published: MDPI AG 2020-12-01
Series:Materials
Subjects:
Online Access:https://www.mdpi.com/1996-1944/13/24/5823
id doaj-25ecfcef53c64424a7d3a6331335bd0c
record_format Article
spelling doaj-25ecfcef53c64424a7d3a6331335bd0c2020-12-22T00:01:23ZengMDPI AGMaterials1996-19442020-12-01135823582310.3390/ma13245823Shaping and Centering Ability, Cyclic Fatigue Resistance and Fractographic Analysis of Three Thermally Treated NiTi Endodontic Instrument SystemsSaulius Drukteinis0Vytaute Peciuliene1Ruta Bendinskaite2Vilma Brukiene3Rasmute Maneliene4Vygandas Rutkunas5Institute of Dentistry, Faculty of Medicine, Vilnius University, Zalgirio 115, LT-08217 Vilnius, LithuaniaInstitute of Dentistry, Faculty of Medicine, Vilnius University, Zalgirio 115, LT-08217 Vilnius, LithuaniaInstitute of Dentistry, Faculty of Medicine, Vilnius University, Zalgirio 115, LT-08217 Vilnius, LithuaniaInstitute of Dentistry, Faculty of Medicine, Vilnius University, Zalgirio 115, LT-08217 Vilnius, LithuaniaInstitute of Dentistry, Faculty of Medicine, Vilnius University, Zalgirio 115, LT-08217 Vilnius, LithuaniaInstitute of Dentistry, Faculty of Medicine, Vilnius University, Zalgirio 115, LT-08217 Vilnius, LithuaniaThe better understanding of the clinically important behavioral features of new instrument systems has an important significance for the clinical endodontics. This study aimed to investigate the shaping and centering ability as well as cyclic fatigue resistance of HyFlex CM (CM), HyFlex EDM (EDM) and EdgeFile (EF) thermally treated nickel–titanium (NiTi) endodontic instrument systems. Sixty curved root canals of the mesial roots of mandibular molars were randomly assigned into three groups (<i>n</i> = 20) and shaped using CM, EDM and EF files up to the size 40 and taper 04 of the instruments. µCT scanning of the specimens before and after preparation was performed and the morphometric 2D and 3D parameters were evaluated in the apical, middle and coronal thirds of root canals. In each group, 40.04 instruments (<i>n</i> = 20) were subjected to the cyclic fatigue resistance test in artificial root canals at 37 °C temperature until fractures occurred, and the number of cycles to failure (NCF) was calculated. The fractographic analysis was performed using a scanning electron microscope, evaluating topographic features and surface profiles of the separated instruments. The one-way analysis of variance with post hoc Tuckey’s test was used for statistical analysis of the data; the significance level was set at 5%. All systems prepared the comparable percentage of root canal surface with the similar magnitude of canal transportation in all root thirds (<i>p</i> > 0.05), but demonstrated significantly different resistance to cyclic fatigue (<i>p</i> < 0.05). The most resistant to fracture was EF, followed by EDM and CM. The length of the fractured fragments was not significantly different between the groups, and fractographic analysis by SEM detected the typical topographic features of separated thermally treated NiTi instrument surfaces.https://www.mdpi.com/1996-1944/13/24/5823cyclic fatiguefractographic analysismicro-computed tomographynickel–titaniumrotary movementroot canal shaping
collection DOAJ
language English
format Article
sources DOAJ
author Saulius Drukteinis
Vytaute Peciuliene
Ruta Bendinskaite
Vilma Brukiene
Rasmute Maneliene
Vygandas Rutkunas
spellingShingle Saulius Drukteinis
Vytaute Peciuliene
Ruta Bendinskaite
Vilma Brukiene
Rasmute Maneliene
Vygandas Rutkunas
Shaping and Centering Ability, Cyclic Fatigue Resistance and Fractographic Analysis of Three Thermally Treated NiTi Endodontic Instrument Systems
Materials
cyclic fatigue
fractographic analysis
micro-computed tomography
nickel–titanium
rotary movement
root canal shaping
author_facet Saulius Drukteinis
Vytaute Peciuliene
Ruta Bendinskaite
Vilma Brukiene
Rasmute Maneliene
Vygandas Rutkunas
author_sort Saulius Drukteinis
title Shaping and Centering Ability, Cyclic Fatigue Resistance and Fractographic Analysis of Three Thermally Treated NiTi Endodontic Instrument Systems
title_short Shaping and Centering Ability, Cyclic Fatigue Resistance and Fractographic Analysis of Three Thermally Treated NiTi Endodontic Instrument Systems
title_full Shaping and Centering Ability, Cyclic Fatigue Resistance and Fractographic Analysis of Three Thermally Treated NiTi Endodontic Instrument Systems
title_fullStr Shaping and Centering Ability, Cyclic Fatigue Resistance and Fractographic Analysis of Three Thermally Treated NiTi Endodontic Instrument Systems
title_full_unstemmed Shaping and Centering Ability, Cyclic Fatigue Resistance and Fractographic Analysis of Three Thermally Treated NiTi Endodontic Instrument Systems
title_sort shaping and centering ability, cyclic fatigue resistance and fractographic analysis of three thermally treated niti endodontic instrument systems
publisher MDPI AG
series Materials
issn 1996-1944
publishDate 2020-12-01
description The better understanding of the clinically important behavioral features of new instrument systems has an important significance for the clinical endodontics. This study aimed to investigate the shaping and centering ability as well as cyclic fatigue resistance of HyFlex CM (CM), HyFlex EDM (EDM) and EdgeFile (EF) thermally treated nickel–titanium (NiTi) endodontic instrument systems. Sixty curved root canals of the mesial roots of mandibular molars were randomly assigned into three groups (<i>n</i> = 20) and shaped using CM, EDM and EF files up to the size 40 and taper 04 of the instruments. µCT scanning of the specimens before and after preparation was performed and the morphometric 2D and 3D parameters were evaluated in the apical, middle and coronal thirds of root canals. In each group, 40.04 instruments (<i>n</i> = 20) were subjected to the cyclic fatigue resistance test in artificial root canals at 37 °C temperature until fractures occurred, and the number of cycles to failure (NCF) was calculated. The fractographic analysis was performed using a scanning electron microscope, evaluating topographic features and surface profiles of the separated instruments. The one-way analysis of variance with post hoc Tuckey’s test was used for statistical analysis of the data; the significance level was set at 5%. All systems prepared the comparable percentage of root canal surface with the similar magnitude of canal transportation in all root thirds (<i>p</i> > 0.05), but demonstrated significantly different resistance to cyclic fatigue (<i>p</i> < 0.05). The most resistant to fracture was EF, followed by EDM and CM. The length of the fractured fragments was not significantly different between the groups, and fractographic analysis by SEM detected the typical topographic features of separated thermally treated NiTi instrument surfaces.
topic cyclic fatigue
fractographic analysis
micro-computed tomography
nickel–titanium
rotary movement
root canal shaping
url https://www.mdpi.com/1996-1944/13/24/5823
work_keys_str_mv AT sauliusdrukteinis shapingandcenteringabilitycyclicfatigueresistanceandfractographicanalysisofthreethermallytreatednitiendodonticinstrumentsystems
AT vytautepeciuliene shapingandcenteringabilitycyclicfatigueresistanceandfractographicanalysisofthreethermallytreatednitiendodonticinstrumentsystems
AT rutabendinskaite shapingandcenteringabilitycyclicfatigueresistanceandfractographicanalysisofthreethermallytreatednitiendodonticinstrumentsystems
AT vilmabrukiene shapingandcenteringabilitycyclicfatigueresistanceandfractographicanalysisofthreethermallytreatednitiendodonticinstrumentsystems
AT rasmutemaneliene shapingandcenteringabilitycyclicfatigueresistanceandfractographicanalysisofthreethermallytreatednitiendodonticinstrumentsystems
AT vygandasrutkunas shapingandcenteringabilitycyclicfatigueresistanceandfractographicanalysisofthreethermallytreatednitiendodonticinstrumentsystems
_version_ 1724374548531380224