Flow injection chemiluminescence determination of loxoprofen and naproxen with the acidic permanganate-sulfite system
A novel flow injection chemiluminescence (CL) method for the determination of loxoprofen and naproxen was proposed based on the CL system of KMnO4, and Na2SO3 in acid media. The CL intensity of KMnO4-Na2SO3 was greatly enhaneed in the presence of loxoprofen and naproxen. The mechanism of the CL reac...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Elsevier
2011-02-01
|
Series: | Journal of Pharmaceutical Analysis |
Online Access: | http://www.sciencedirect.com/science/article/pii/S2095177911700090 |
id |
doaj-25ab6ba348644e8581e7d89f09cb4bbe |
---|---|
record_format |
Article |
spelling |
doaj-25ab6ba348644e8581e7d89f09cb4bbe2021-04-02T06:35:23ZengElsevierJournal of Pharmaceutical Analysis2095-17792011-02-01115156Flow injection chemiluminescence determination of loxoprofen and naproxen with the acidic permanganate-sulfite systemLi-Juan Wang0Yu-Hai Tang1Yang-Hao Liu2Medical School, Xiâan Jiaotong University, Xiâan 710061, China; Institute of Analytical Sciences, Xiâan Jiaotong University, Xiâan 710061, ChinaInstitute of Analytical Sciences, Xiâan Jiaotong University, Xiâan 710061, China; Corrcsponding author.Institute of Analytical Sciences, Xiâan Jiaotong University, Xiâan 710061, ChinaA novel flow injection chemiluminescence (CL) method for the determination of loxoprofen and naproxen was proposed based on the CL system of KMnO4, and Na2SO3 in acid media. The CL intensity of KMnO4-Na2SO3 was greatly enhaneed in the presence of loxoprofen and naproxen. The mechanism of the CL reaction was studied by the kinetic proecss and UV-vis absorption and the conditions were optimized. Under optimized conditions, the CL intensity was linear with loxoprofen and naproxen concentration in the range of 7.0Â ÃÂ 10â8 â 1.0Â ÃÂ 10â5 g/mL and 2.0Â ÃÂ 10â7 â 4.0Â ÃÂ 10â6 g/mL with the detection limit of 2.0Â ÃÂ 10â8 g/mL and 3.0Â ÃÂ 10â8 g/mL (S/N = 3), respectively. Thc relative standard deviations were 2.39% and 1.37% for 5.0Â ÃÂ 10â7 g/mL naproxen and 5.0Â ÃÂ 10â7 g/mL loxoprofen (n = 10), respectively. The proposed method was satisfactorily applied to thc determination of loxoprofen and naproxen in pharmaceutical preparations. Keywords: chemiluminescence, KMnO4, loxoprofen, naproxenhttp://www.sciencedirect.com/science/article/pii/S2095177911700090 |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Li-Juan Wang Yu-Hai Tang Yang-Hao Liu |
spellingShingle |
Li-Juan Wang Yu-Hai Tang Yang-Hao Liu Flow injection chemiluminescence determination of loxoprofen and naproxen with the acidic permanganate-sulfite system Journal of Pharmaceutical Analysis |
author_facet |
Li-Juan Wang Yu-Hai Tang Yang-Hao Liu |
author_sort |
Li-Juan Wang |
title |
Flow injection chemiluminescence determination of loxoprofen and naproxen with the acidic permanganate-sulfite system |
title_short |
Flow injection chemiluminescence determination of loxoprofen and naproxen with the acidic permanganate-sulfite system |
title_full |
Flow injection chemiluminescence determination of loxoprofen and naproxen with the acidic permanganate-sulfite system |
title_fullStr |
Flow injection chemiluminescence determination of loxoprofen and naproxen with the acidic permanganate-sulfite system |
title_full_unstemmed |
Flow injection chemiluminescence determination of loxoprofen and naproxen with the acidic permanganate-sulfite system |
title_sort |
flow injection chemiluminescence determination of loxoprofen and naproxen with the acidic permanganate-sulfite system |
publisher |
Elsevier |
series |
Journal of Pharmaceutical Analysis |
issn |
2095-1779 |
publishDate |
2011-02-01 |
description |
A novel flow injection chemiluminescence (CL) method for the determination of loxoprofen and naproxen was proposed based on the CL system of KMnO4, and Na2SO3 in acid media. The CL intensity of KMnO4-Na2SO3 was greatly enhaneed in the presence of loxoprofen and naproxen. The mechanism of the CL reaction was studied by the kinetic proecss and UV-vis absorption and the conditions were optimized. Under optimized conditions, the CL intensity was linear with loxoprofen and naproxen concentration in the range of 7.0Â ÃÂ 10â8 â 1.0Â ÃÂ 10â5 g/mL and 2.0Â ÃÂ 10â7 â 4.0Â ÃÂ 10â6 g/mL with the detection limit of 2.0Â ÃÂ 10â8 g/mL and 3.0Â ÃÂ 10â8 g/mL (S/N = 3), respectively. Thc relative standard deviations were 2.39% and 1.37% for 5.0Â ÃÂ 10â7 g/mL naproxen and 5.0Â ÃÂ 10â7 g/mL loxoprofen (n = 10), respectively. The proposed method was satisfactorily applied to thc determination of loxoprofen and naproxen in pharmaceutical preparations. Keywords: chemiluminescence, KMnO4, loxoprofen, naproxen |
url |
http://www.sciencedirect.com/science/article/pii/S2095177911700090 |
work_keys_str_mv |
AT lijuanwang flowinjectionchemiluminescencedeterminationofloxoprofenandnaproxenwiththeacidicpermanganatesulfitesystem AT yuhaitang flowinjectionchemiluminescencedeterminationofloxoprofenandnaproxenwiththeacidicpermanganatesulfitesystem AT yanghaoliu flowinjectionchemiluminescencedeterminationofloxoprofenandnaproxenwiththeacidicpermanganatesulfitesystem |
_version_ |
1724171835660042240 |