The Effects on Screw Fasteners Spacing on Flexural Behavior and Strength Capacity of Cold-Formed Steel Built-Up Box Sections

The capacity and behaviour of cold-formed steel built-up sections are affected by the arrangement of the connections. This study aims to determine the effect of the screw spacing to the bending capacity and behaviour of the cold-formed steel built-up box section which made from lipped-channel (1.0 m...

Full description

Bibliographic Details
Main Authors: Maria Yasinta Menge Making, Ali Awaludin, Bambang Supriyadi
Format: Article
Language:English
Published: Universitas Diponegoro 2021-02-01
Series:Media Komunikasi Teknik Sipil
Subjects:
Online Access:https://ejournal.undip.ac.id/index.php/mkts/article/view/31503
id doaj-25ab09f8b32a4754aa4f243bd9c36ca3
record_format Article
spelling doaj-25ab09f8b32a4754aa4f243bd9c36ca32021-02-02T01:02:24ZengUniversitas DiponegoroMedia Komunikasi Teknik Sipil0854-18092549-67782021-02-0126216317310.14710/mkts.v26i2.3150318037The Effects on Screw Fasteners Spacing on Flexural Behavior and Strength Capacity of Cold-Formed Steel Built-Up Box SectionsMaria Yasinta Menge Making0Ali Awaludin1Bambang Supriyadi2Universitas Gadjah MadaUniversitas Gadjah MadaUniversitas Gadjah MadaThe capacity and behaviour of cold-formed steel built-up sections are affected by the arrangement of the connections. This study aims to determine the effect of the screw spacing to the bending capacity and behaviour of the cold-formed steel built-up box section which made from lipped-channel (1.0 mm thick, 81 mm web height, 8.5 mm lip height, upper and lower wing width 38 mm and 40 mm). A total of 19 beams with a length of 1200 mm each are subjected to pure bending moments by applying two point loads spaced 600 mm in the midspan. The screw spacing variations in the moment span are 100 mm, 150 mm, 200 mm, 250 mm, 300 mm, 328 mm, and 350 mm. The test results show the average of bending capacity of the beam test is increasing with the reduction in screw spacing while the screw configuration also affects the beam capacity. Analysis of the bending capacity using the effective width method and the direct strength method based on AISI S100-16 gives very conservative results. The failure mode of the built-up box sections were observed in the form of local buckling, distortion, and lateral-torsional buckling.https://ejournal.undip.ac.id/index.php/mkts/article/view/31503baja canai dinginpenampang tersusun bokskapasitas lentur
collection DOAJ
language English
format Article
sources DOAJ
author Maria Yasinta Menge Making
Ali Awaludin
Bambang Supriyadi
spellingShingle Maria Yasinta Menge Making
Ali Awaludin
Bambang Supriyadi
The Effects on Screw Fasteners Spacing on Flexural Behavior and Strength Capacity of Cold-Formed Steel Built-Up Box Sections
Media Komunikasi Teknik Sipil
baja canai dingin
penampang tersusun boks
kapasitas lentur
author_facet Maria Yasinta Menge Making
Ali Awaludin
Bambang Supriyadi
author_sort Maria Yasinta Menge Making
title The Effects on Screw Fasteners Spacing on Flexural Behavior and Strength Capacity of Cold-Formed Steel Built-Up Box Sections
title_short The Effects on Screw Fasteners Spacing on Flexural Behavior and Strength Capacity of Cold-Formed Steel Built-Up Box Sections
title_full The Effects on Screw Fasteners Spacing on Flexural Behavior and Strength Capacity of Cold-Formed Steel Built-Up Box Sections
title_fullStr The Effects on Screw Fasteners Spacing on Flexural Behavior and Strength Capacity of Cold-Formed Steel Built-Up Box Sections
title_full_unstemmed The Effects on Screw Fasteners Spacing on Flexural Behavior and Strength Capacity of Cold-Formed Steel Built-Up Box Sections
title_sort effects on screw fasteners spacing on flexural behavior and strength capacity of cold-formed steel built-up box sections
publisher Universitas Diponegoro
series Media Komunikasi Teknik Sipil
issn 0854-1809
2549-6778
publishDate 2021-02-01
description The capacity and behaviour of cold-formed steel built-up sections are affected by the arrangement of the connections. This study aims to determine the effect of the screw spacing to the bending capacity and behaviour of the cold-formed steel built-up box section which made from lipped-channel (1.0 mm thick, 81 mm web height, 8.5 mm lip height, upper and lower wing width 38 mm and 40 mm). A total of 19 beams with a length of 1200 mm each are subjected to pure bending moments by applying two point loads spaced 600 mm in the midspan. The screw spacing variations in the moment span are 100 mm, 150 mm, 200 mm, 250 mm, 300 mm, 328 mm, and 350 mm. The test results show the average of bending capacity of the beam test is increasing with the reduction in screw spacing while the screw configuration also affects the beam capacity. Analysis of the bending capacity using the effective width method and the direct strength method based on AISI S100-16 gives very conservative results. The failure mode of the built-up box sections were observed in the form of local buckling, distortion, and lateral-torsional buckling.
topic baja canai dingin
penampang tersusun boks
kapasitas lentur
url https://ejournal.undip.ac.id/index.php/mkts/article/view/31503
work_keys_str_mv AT mariayasintamengemaking theeffectsonscrewfastenersspacingonflexuralbehaviorandstrengthcapacityofcoldformedsteelbuiltupboxsections
AT aliawaludin theeffectsonscrewfastenersspacingonflexuralbehaviorandstrengthcapacityofcoldformedsteelbuiltupboxsections
AT bambangsupriyadi theeffectsonscrewfastenersspacingonflexuralbehaviorandstrengthcapacityofcoldformedsteelbuiltupboxsections
AT mariayasintamengemaking effectsonscrewfastenersspacingonflexuralbehaviorandstrengthcapacityofcoldformedsteelbuiltupboxsections
AT aliawaludin effectsonscrewfastenersspacingonflexuralbehaviorandstrengthcapacityofcoldformedsteelbuiltupboxsections
AT bambangsupriyadi effectsonscrewfastenersspacingonflexuralbehaviorandstrengthcapacityofcoldformedsteelbuiltupboxsections
_version_ 1724312473914310656