Successful toric intraocular lens implantation in a patient with induced cataract and astigmatism after posterior chamber toric phakic intraocular lens implantation: a case report

<p>Abstract</p> <p>Introduction</p> <p>We report the case of a patient in whom simultaneous toric phakic intraocular lens removal and phacoemulsification with toric intraocular lens implantation were beneficial for reducing pre-existing astigmatism and acquiring good vi...

Full description

Bibliographic Details
Main Authors: Kamiya Kazutaka, Nakamura Akio, Miyake Hideyuki, Nishimoto Hiroyuki, Shimizu Kimiya
Format: Article
Language:English
Published: BMC 2012-04-01
Series:Journal of Medical Case Reports
Online Access:http://www.jmedicalcasereports.com/content/6/1/109
id doaj-24fb4e8d238d41c7bcd26bc2f9d7f379
record_format Article
spelling doaj-24fb4e8d238d41c7bcd26bc2f9d7f3792020-11-24T23:28:19ZengBMCJournal of Medical Case Reports1752-19472012-04-016110910.1186/1752-1947-6-109Successful toric intraocular lens implantation in a patient with induced cataract and astigmatism after posterior chamber toric phakic intraocular lens implantation: a case reportKamiya KazutakaNakamura AkioMiyake HideyukiNishimoto HiroyukiShimizu Kimiya<p>Abstract</p> <p>Introduction</p> <p>We report the case of a patient in whom simultaneous toric phakic intraocular lens removal and phacoemulsification with toric intraocular lens implantation were beneficial for reducing pre-existing astigmatism and acquiring good visual outcomes in eyes with implantable collamer lens-induced cataract and astigmatism.</p> <p>Case presentation</p> <p>A 53-year-old woman had undergone toric implantable collamer lens implantation three years earlier. After informed consent was obtained, we performed simultaneous toric implantable collamer lens removal and phacoemulsification with toric intraocular lens implantation. Preoperatively, the manifest refraction was 0, -0.5 × 15, with an uncorrected visual acuity of 0.7 and a best spectacle-corrected visual acuity of 0.8. Postoperatively, the manifest refraction was improved to 0, -0.5 × 180, with an uncorrected visual acuity of 1.2 and a best spectacle-corrected visual acuity of 1.5. No vision-threatening complications were observed.</p> <p>Conclusion</p> <p>Toric intraocular lens implantation may be a good surgical option for the correction of spherical and cylindrical errors in eyes with implantable collamer lens-induced cataract and astigmatism.</p> http://www.jmedicalcasereports.com/content/6/1/109
collection DOAJ
language English
format Article
sources DOAJ
author Kamiya Kazutaka
Nakamura Akio
Miyake Hideyuki
Nishimoto Hiroyuki
Shimizu Kimiya
spellingShingle Kamiya Kazutaka
Nakamura Akio
Miyake Hideyuki
Nishimoto Hiroyuki
Shimizu Kimiya
Successful toric intraocular lens implantation in a patient with induced cataract and astigmatism after posterior chamber toric phakic intraocular lens implantation: a case report
Journal of Medical Case Reports
author_facet Kamiya Kazutaka
Nakamura Akio
Miyake Hideyuki
Nishimoto Hiroyuki
Shimizu Kimiya
author_sort Kamiya Kazutaka
title Successful toric intraocular lens implantation in a patient with induced cataract and astigmatism after posterior chamber toric phakic intraocular lens implantation: a case report
title_short Successful toric intraocular lens implantation in a patient with induced cataract and astigmatism after posterior chamber toric phakic intraocular lens implantation: a case report
title_full Successful toric intraocular lens implantation in a patient with induced cataract and astigmatism after posterior chamber toric phakic intraocular lens implantation: a case report
title_fullStr Successful toric intraocular lens implantation in a patient with induced cataract and astigmatism after posterior chamber toric phakic intraocular lens implantation: a case report
title_full_unstemmed Successful toric intraocular lens implantation in a patient with induced cataract and astigmatism after posterior chamber toric phakic intraocular lens implantation: a case report
title_sort successful toric intraocular lens implantation in a patient with induced cataract and astigmatism after posterior chamber toric phakic intraocular lens implantation: a case report
publisher BMC
series Journal of Medical Case Reports
issn 1752-1947
publishDate 2012-04-01
description <p>Abstract</p> <p>Introduction</p> <p>We report the case of a patient in whom simultaneous toric phakic intraocular lens removal and phacoemulsification with toric intraocular lens implantation were beneficial for reducing pre-existing astigmatism and acquiring good visual outcomes in eyes with implantable collamer lens-induced cataract and astigmatism.</p> <p>Case presentation</p> <p>A 53-year-old woman had undergone toric implantable collamer lens implantation three years earlier. After informed consent was obtained, we performed simultaneous toric implantable collamer lens removal and phacoemulsification with toric intraocular lens implantation. Preoperatively, the manifest refraction was 0, -0.5 × 15, with an uncorrected visual acuity of 0.7 and a best spectacle-corrected visual acuity of 0.8. Postoperatively, the manifest refraction was improved to 0, -0.5 × 180, with an uncorrected visual acuity of 1.2 and a best spectacle-corrected visual acuity of 1.5. No vision-threatening complications were observed.</p> <p>Conclusion</p> <p>Toric intraocular lens implantation may be a good surgical option for the correction of spherical and cylindrical errors in eyes with implantable collamer lens-induced cataract and astigmatism.</p>
url http://www.jmedicalcasereports.com/content/6/1/109
work_keys_str_mv AT kamiyakazutaka successfultoricintraocularlensimplantationinapatientwithinducedcataractandastigmatismafterposteriorchambertoricphakicintraocularlensimplantationacasereport
AT nakamuraakio successfultoricintraocularlensimplantationinapatientwithinducedcataractandastigmatismafterposteriorchambertoricphakicintraocularlensimplantationacasereport
AT miyakehideyuki successfultoricintraocularlensimplantationinapatientwithinducedcataractandastigmatismafterposteriorchambertoricphakicintraocularlensimplantationacasereport
AT nishimotohiroyuki successfultoricintraocularlensimplantationinapatientwithinducedcataractandastigmatismafterposteriorchambertoricphakicintraocularlensimplantationacasereport
AT shimizukimiya successfultoricintraocularlensimplantationinapatientwithinducedcataractandastigmatismafterposteriorchambertoricphakicintraocularlensimplantationacasereport
_version_ 1725549726661607424