Cryostat for the provision of liquid hydrogen with a variable ortho-para ratio for a low-dimensional cold neutron moderator
A significant contribution to the enhancement of the neutron brilliance achievable with Compact Accelerator-driven Neutron Sources (CANS) can be made by an optimized cold moderator design. When using liquid para-H2 as the moderating medium, the concept of low-dimensional cold moderators can be emplo...