Soil-Structure Interaction Effect on Fragility Curve of 3D Models of Concrete Moment-Resisting Buildings

This paper presents the probabilistic generation of collapse fragility curves for evaluating the performance of 3D, reinforced concrete (RC) moment-resisting building models, considering soil-structure interaction (SSI) by concentration on seismic uncertainties. It considers collapse as the loss of...

Full description

Bibliographic Details
Main Authors: Ali Anvarsamarin, Fayaz Rahimzadeh Rofooei, Masoud Nekooei
Format: Article
Language:English
Published: Hindawi Limited 2018-01-01
Series:Shock and Vibration
Online Access:http://dx.doi.org/10.1155/2018/7270137
id doaj-248571a403444cf0b4eaba8d23d6ab54
record_format Article
spelling doaj-248571a403444cf0b4eaba8d23d6ab542020-11-25T01:11:52ZengHindawi LimitedShock and Vibration1070-96221875-92032018-01-01201810.1155/2018/72701377270137Soil-Structure Interaction Effect on Fragility Curve of 3D Models of Concrete Moment-Resisting BuildingsAli Anvarsamarin0Fayaz Rahimzadeh Rofooei1Masoud Nekooei2Department of Civil Engineering, Science and Research Branch, Islamic Azad University, Tehran, IranCivil Engineering Department, Sharif University of Technology, Tehran, IranDepartment of Civil Engineering, Science and Research Branch, Islamic Azad University, Tehran, IranThis paper presents the probabilistic generation of collapse fragility curves for evaluating the performance of 3D, reinforced concrete (RC) moment-resisting building models, considering soil-structure interaction (SSI) by concentration on seismic uncertainties. It considers collapse as the loss of lateral load-resisting capacity of the building structures due to severe ground shaking and consequent large interstory drifts intensified by P-Δ effects as well as the strength and stiffness deterioration of their lateral load carrying systems. The estimation of the collapse performance of structures requires the relation between the intensity measure (IM) and the probability of collapse that is determined using the generated collapse fragility curves. Considering a number of 6-, 12-, and 18-story, 3D, RC moment-resisting buildings, two scalar IMs are employed to estimate their collapse fragility curve. On the other hand, the effect of the site soil type on the collapse fragility curves was taken into account by considering the soil-structure interaction. According to the obtained results, adopting the average of spectral acceleration (Saavg) intensity measure is more efficient in capturing the effect of the inherent uncertainties of the strong ground motions on the structural response parameters. In addition, considering the SSI for soil type D with shear-wave velocity of 180 m/s to 360 m/s reduces the median of intensity measure (IM = Sa(T1)) of fragility curve in 6-, 12-, and 18-story buildings by 4.92%, 22.26%, and 23.03%, respectively.http://dx.doi.org/10.1155/2018/7270137
collection DOAJ
language English
format Article
sources DOAJ
author Ali Anvarsamarin
Fayaz Rahimzadeh Rofooei
Masoud Nekooei
spellingShingle Ali Anvarsamarin
Fayaz Rahimzadeh Rofooei
Masoud Nekooei
Soil-Structure Interaction Effect on Fragility Curve of 3D Models of Concrete Moment-Resisting Buildings
Shock and Vibration
author_facet Ali Anvarsamarin
Fayaz Rahimzadeh Rofooei
Masoud Nekooei
author_sort Ali Anvarsamarin
title Soil-Structure Interaction Effect on Fragility Curve of 3D Models of Concrete Moment-Resisting Buildings
title_short Soil-Structure Interaction Effect on Fragility Curve of 3D Models of Concrete Moment-Resisting Buildings
title_full Soil-Structure Interaction Effect on Fragility Curve of 3D Models of Concrete Moment-Resisting Buildings
title_fullStr Soil-Structure Interaction Effect on Fragility Curve of 3D Models of Concrete Moment-Resisting Buildings
title_full_unstemmed Soil-Structure Interaction Effect on Fragility Curve of 3D Models of Concrete Moment-Resisting Buildings
title_sort soil-structure interaction effect on fragility curve of 3d models of concrete moment-resisting buildings
publisher Hindawi Limited
series Shock and Vibration
issn 1070-9622
1875-9203
publishDate 2018-01-01
description This paper presents the probabilistic generation of collapse fragility curves for evaluating the performance of 3D, reinforced concrete (RC) moment-resisting building models, considering soil-structure interaction (SSI) by concentration on seismic uncertainties. It considers collapse as the loss of lateral load-resisting capacity of the building structures due to severe ground shaking and consequent large interstory drifts intensified by P-Δ effects as well as the strength and stiffness deterioration of their lateral load carrying systems. The estimation of the collapse performance of structures requires the relation between the intensity measure (IM) and the probability of collapse that is determined using the generated collapse fragility curves. Considering a number of 6-, 12-, and 18-story, 3D, RC moment-resisting buildings, two scalar IMs are employed to estimate their collapse fragility curve. On the other hand, the effect of the site soil type on the collapse fragility curves was taken into account by considering the soil-structure interaction. According to the obtained results, adopting the average of spectral acceleration (Saavg) intensity measure is more efficient in capturing the effect of the inherent uncertainties of the strong ground motions on the structural response parameters. In addition, considering the SSI for soil type D with shear-wave velocity of 180 m/s to 360 m/s reduces the median of intensity measure (IM = Sa(T1)) of fragility curve in 6-, 12-, and 18-story buildings by 4.92%, 22.26%, and 23.03%, respectively.
url http://dx.doi.org/10.1155/2018/7270137
work_keys_str_mv AT alianvarsamarin soilstructureinteractioneffectonfragilitycurveof3dmodelsofconcretemomentresistingbuildings
AT fayazrahimzadehrofooei soilstructureinteractioneffectonfragilitycurveof3dmodelsofconcretemomentresistingbuildings
AT masoudnekooei soilstructureinteractioneffectonfragilitycurveof3dmodelsofconcretemomentresistingbuildings
_version_ 1725169253520244736