Measurement of trigger and cascade section runtimes in 6 MV switches using fiber coupled photodetectors

Since October 2007 Sandia National Laboratories has operated the refurbished Z machine at an improved load current of 26 MA yielding 400 TW of x-ray power. The current pulse shape to the load is controlled by 36 independently timed laser triggered gas switches. As part of the refurbishment effort, a...

Full description

Bibliographic Details
Main Authors: Jens Schwarz, David Bliss, Joe Woodworth, Mark Savage, James Potter, Tom Avila, Stephen Ploor, Patrick Rambo, Briggs Atherton
Format: Article
Language:English
Published: American Physical Society 2012-07-01
Series:Physical Review Special Topics. Accelerators and Beams
Online Access:http://doi.org/10.1103/PhysRevSTAB.15.072802
id doaj-24682ac294e34235a05f6fe9b17fff45
record_format Article
spelling doaj-24682ac294e34235a05f6fe9b17fff452020-11-25T02:15:33ZengAmerican Physical SocietyPhysical Review Special Topics. Accelerators and Beams1098-44022012-07-0115707280210.1103/PhysRevSTAB.15.072802Measurement of trigger and cascade section runtimes in 6 MV switches using fiber coupled photodetectorsJens SchwarzDavid BlissJoe WoodworthMark SavageJames PotterTom AvilaStephen PloorPatrick RamboBriggs AthertonSince October 2007 Sandia National Laboratories has operated the refurbished Z machine at an improved load current of 26 MA yielding 400 TW of x-ray power. The current pulse shape to the load is controlled by 36 independently timed laser triggered gas switches. As part of the refurbishment effort, a fiber coupled laser spark detector system has been installed which is able to detect the laser generated plasma in situ inside the trigger section of the high voltage switch. In this paper we describe how this detection system can be used to characterize the discharge dynamics of these 5.9 MV, 820 kA switches.http://doi.org/10.1103/PhysRevSTAB.15.072802
collection DOAJ
language English
format Article
sources DOAJ
author Jens Schwarz
David Bliss
Joe Woodworth
Mark Savage
James Potter
Tom Avila
Stephen Ploor
Patrick Rambo
Briggs Atherton
spellingShingle Jens Schwarz
David Bliss
Joe Woodworth
Mark Savage
James Potter
Tom Avila
Stephen Ploor
Patrick Rambo
Briggs Atherton
Measurement of trigger and cascade section runtimes in 6 MV switches using fiber coupled photodetectors
Physical Review Special Topics. Accelerators and Beams
author_facet Jens Schwarz
David Bliss
Joe Woodworth
Mark Savage
James Potter
Tom Avila
Stephen Ploor
Patrick Rambo
Briggs Atherton
author_sort Jens Schwarz
title Measurement of trigger and cascade section runtimes in 6 MV switches using fiber coupled photodetectors
title_short Measurement of trigger and cascade section runtimes in 6 MV switches using fiber coupled photodetectors
title_full Measurement of trigger and cascade section runtimes in 6 MV switches using fiber coupled photodetectors
title_fullStr Measurement of trigger and cascade section runtimes in 6 MV switches using fiber coupled photodetectors
title_full_unstemmed Measurement of trigger and cascade section runtimes in 6 MV switches using fiber coupled photodetectors
title_sort measurement of trigger and cascade section runtimes in 6 mv switches using fiber coupled photodetectors
publisher American Physical Society
series Physical Review Special Topics. Accelerators and Beams
issn 1098-4402
publishDate 2012-07-01
description Since October 2007 Sandia National Laboratories has operated the refurbished Z machine at an improved load current of 26 MA yielding 400 TW of x-ray power. The current pulse shape to the load is controlled by 36 independently timed laser triggered gas switches. As part of the refurbishment effort, a fiber coupled laser spark detector system has been installed which is able to detect the laser generated plasma in situ inside the trigger section of the high voltage switch. In this paper we describe how this detection system can be used to characterize the discharge dynamics of these 5.9 MV, 820 kA switches.
url http://doi.org/10.1103/PhysRevSTAB.15.072802
work_keys_str_mv AT jensschwarz measurementoftriggerandcascadesectionruntimesin6mvswitchesusingfibercoupledphotodetectors
AT davidbliss measurementoftriggerandcascadesectionruntimesin6mvswitchesusingfibercoupledphotodetectors
AT joewoodworth measurementoftriggerandcascadesectionruntimesin6mvswitchesusingfibercoupledphotodetectors
AT marksavage measurementoftriggerandcascadesectionruntimesin6mvswitchesusingfibercoupledphotodetectors
AT jamespotter measurementoftriggerandcascadesectionruntimesin6mvswitchesusingfibercoupledphotodetectors
AT tomavila measurementoftriggerandcascadesectionruntimesin6mvswitchesusingfibercoupledphotodetectors
AT stephenploor measurementoftriggerandcascadesectionruntimesin6mvswitchesusingfibercoupledphotodetectors
AT patrickrambo measurementoftriggerandcascadesectionruntimesin6mvswitchesusingfibercoupledphotodetectors
AT briggsatherton measurementoftriggerandcascadesectionruntimesin6mvswitchesusingfibercoupledphotodetectors
_version_ 1724895539405783040