Method for estimation of hippuric acid as a biomarker of toluene exposure in urine by high-performance liquid chromatography after extraction with ethyl acetate
Aim: This study aimed to establish liquid–liquid extraction (LLE) for estimation of hippuric acid (HA) in urine as a biomarker of the toluene exposure by high-performance liquid chromatography equipped with photodiode array detector (HPLC-PDAD). Method: HA in urine was extracted by LLE and determin...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Wolters Kluwer Medknow Publications
2019-01-01
|
Series: | Environmental Disease |
Subjects: | |
Online Access: | http://www.environmentmed.org/article.asp?issn=2468-5690;year=2019;volume=4;issue=1;spage=17;epage=22;aulast=Yadav |
id |
doaj-24275e8c2fe14ddea70e42e86dd25336 |
---|---|
record_format |
Article |
spelling |
doaj-24275e8c2fe14ddea70e42e86dd253362020-11-25T01:19:35ZengWolters Kluwer Medknow PublicationsEnvironmental Disease2468-56902468-57042019-01-0141172210.4103/ed.ed_22_18Method for estimation of hippuric acid as a biomarker of toluene exposure in urine by high-performance liquid chromatography after extraction with ethyl acetateAnupa YadavAnirban BasuAmit ChakarbartiAim: This study aimed to establish liquid–liquid extraction (LLE) for estimation of hippuric acid (HA) in urine as a biomarker of the toluene exposure by high-performance liquid chromatography equipped with photodiode array detector (HPLC-PDAD). Method: HA in urine was extracted by LLE and determined by HPLC-PDAD. The operating conditions with HPLC were ODS-2 hypersil column (250 mm × 4.6 mm, 5 μm), 0.1% trifluoro acetic acid (TFA) in acetonitrile and 0.1% TFA in water as mobile phase, 1 ml/min flow rate, and wavelength of 205 nm. The validity of the present method was tested by the estimation of HA in urine samples, collected from toluene-exposed (shoe workers) and unexposed or control subjects. Results: Binary gradient system was used to achieve optimum separation. The analytical curve prepared for HA in aqueous solution in the range of 0.5–10 μg/ml showed determination coefficient value (R2) 0.998. Limit of detection and quantification (LOQ) were 0.46 and 1.53 μg/ml, respectively. The coefficients of variance for intraday precision were 1.4% for HA standard (5 μg/ml) and 1.1% for pooled urine, whereas inter-day precision values were 3.2% and 4.9% for HA standard and pooled urine, respectively. Method recovery obtained was 96%–120% for HA solutions containing 2, 3, and 5 μg/ml, demonstrating that precision and recovery of method were satisfactory. Compared to unexposed group, exposed group had significantly more HA. It was found significantly (P < 0.05) higher in urine of exposed workers (32.52 ± 10.91) than unexposed group (16.21 ± 10.14). Conclusion: Sample preparation by LLE is simple and cost-effective for the determination of HA as a biomarker of toluene exposure by HPLC-PDAD. It can be used to detect HA in urine for population exposed to toluene.http://www.environmentmed.org/article.asp?issn=2468-5690;year=2019;volume=4;issue=1;spage=17;epage=22;aulast=YadavHigh-performance liquid chromatographyhippuric acidliquid–liquid extractionphotodiode array detectortoluene exposureurine |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Anupa Yadav Anirban Basu Amit Chakarbarti |
spellingShingle |
Anupa Yadav Anirban Basu Amit Chakarbarti Method for estimation of hippuric acid as a biomarker of toluene exposure in urine by high-performance liquid chromatography after extraction with ethyl acetate Environmental Disease High-performance liquid chromatography hippuric acid liquid–liquid extraction photodiode array detector toluene exposure urine |
author_facet |
Anupa Yadav Anirban Basu Amit Chakarbarti |
author_sort |
Anupa Yadav |
title |
Method for estimation of hippuric acid as a biomarker of toluene exposure in urine by high-performance liquid chromatography after extraction with ethyl acetate |
title_short |
Method for estimation of hippuric acid as a biomarker of toluene exposure in urine by high-performance liquid chromatography after extraction with ethyl acetate |
title_full |
Method for estimation of hippuric acid as a biomarker of toluene exposure in urine by high-performance liquid chromatography after extraction with ethyl acetate |
title_fullStr |
Method for estimation of hippuric acid as a biomarker of toluene exposure in urine by high-performance liquid chromatography after extraction with ethyl acetate |
title_full_unstemmed |
Method for estimation of hippuric acid as a biomarker of toluene exposure in urine by high-performance liquid chromatography after extraction with ethyl acetate |
title_sort |
method for estimation of hippuric acid as a biomarker of toluene exposure in urine by high-performance liquid chromatography after extraction with ethyl acetate |
publisher |
Wolters Kluwer Medknow Publications |
series |
Environmental Disease |
issn |
2468-5690 2468-5704 |
publishDate |
2019-01-01 |
description |
Aim: This study aimed to establish liquid–liquid extraction (LLE) for estimation of hippuric acid (HA) in urine as a biomarker of the toluene exposure by high-performance liquid chromatography equipped with photodiode array detector (HPLC-PDAD).
Method: HA in urine was extracted by LLE and determined by HPLC-PDAD. The operating conditions with HPLC were ODS-2 hypersil column (250 mm × 4.6 mm, 5 μm), 0.1% trifluoro acetic acid (TFA) in acetonitrile and 0.1% TFA in water as mobile phase, 1 ml/min flow rate, and wavelength of 205 nm. The validity of the present method was tested by the estimation of HA in urine samples, collected from toluene-exposed (shoe workers) and unexposed or control subjects.
Results: Binary gradient system was used to achieve optimum separation. The analytical curve prepared for HA in aqueous solution in the range of 0.5–10 μg/ml showed determination coefficient value (R2) 0.998. Limit of detection and quantification (LOQ) were 0.46 and 1.53 μg/ml, respectively. The coefficients of variance for intraday precision were 1.4% for HA standard (5 μg/ml) and 1.1% for pooled urine, whereas inter-day precision values were 3.2% and 4.9% for HA standard and pooled urine, respectively. Method recovery obtained was 96%–120% for HA solutions containing 2, 3, and 5 μg/ml, demonstrating that precision and recovery of method were satisfactory. Compared to unexposed group, exposed group had significantly more HA. It was found significantly (P < 0.05) higher in urine of exposed workers (32.52 ± 10.91) than unexposed group (16.21 ± 10.14).
Conclusion: Sample preparation by LLE is simple and cost-effective for the determination of HA as a biomarker of toluene exposure by HPLC-PDAD. It can be used to detect HA in urine for population exposed to toluene. |
topic |
High-performance liquid chromatography hippuric acid liquid–liquid extraction photodiode array detector toluene exposure urine |
url |
http://www.environmentmed.org/article.asp?issn=2468-5690;year=2019;volume=4;issue=1;spage=17;epage=22;aulast=Yadav |
work_keys_str_mv |
AT anupayadav methodforestimationofhippuricacidasabiomarkeroftolueneexposureinurinebyhighperformanceliquidchromatographyafterextractionwithethylacetate AT anirbanbasu methodforestimationofhippuricacidasabiomarkeroftolueneexposureinurinebyhighperformanceliquidchromatographyafterextractionwithethylacetate AT amitchakarbarti methodforestimationofhippuricacidasabiomarkeroftolueneexposureinurinebyhighperformanceliquidchromatographyafterextractionwithethylacetate |
_version_ |
1725137358230126592 |