Method for estimation of hippuric acid as a biomarker of toluene exposure in urine by high-performance liquid chromatography after extraction with ethyl acetate

Aim: This study aimed to establish liquid–liquid extraction (LLE) for estimation of hippuric acid (HA) in urine as a biomarker of the toluene exposure by high-performance liquid chromatography equipped with photodiode array detector (HPLC-PDAD). Method: HA in urine was extracted by LLE and determin...

Full description

Bibliographic Details
Main Authors: Anupa Yadav, Anirban Basu, Amit Chakarbarti
Format: Article
Language:English
Published: Wolters Kluwer Medknow Publications 2019-01-01
Series:Environmental Disease
Subjects:
Online Access:http://www.environmentmed.org/article.asp?issn=2468-5690;year=2019;volume=4;issue=1;spage=17;epage=22;aulast=Yadav
id doaj-24275e8c2fe14ddea70e42e86dd25336
record_format Article
spelling doaj-24275e8c2fe14ddea70e42e86dd253362020-11-25T01:19:35ZengWolters Kluwer Medknow PublicationsEnvironmental Disease2468-56902468-57042019-01-0141172210.4103/ed.ed_22_18Method for estimation of hippuric acid as a biomarker of toluene exposure in urine by high-performance liquid chromatography after extraction with ethyl acetateAnupa YadavAnirban BasuAmit ChakarbartiAim: This study aimed to establish liquid–liquid extraction (LLE) for estimation of hippuric acid (HA) in urine as a biomarker of the toluene exposure by high-performance liquid chromatography equipped with photodiode array detector (HPLC-PDAD). Method: HA in urine was extracted by LLE and determined by HPLC-PDAD. The operating conditions with HPLC were ODS-2 hypersil column (250 mm × 4.6 mm, 5 μm), 0.1% trifluoro acetic acid (TFA) in acetonitrile and 0.1% TFA in water as mobile phase, 1 ml/min flow rate, and wavelength of 205 nm. The validity of the present method was tested by the estimation of HA in urine samples, collected from toluene-exposed (shoe workers) and unexposed or control subjects. Results: Binary gradient system was used to achieve optimum separation. The analytical curve prepared for HA in aqueous solution in the range of 0.5–10 μg/ml showed determination coefficient value (R2) 0.998. Limit of detection and quantification (LOQ) were 0.46 and 1.53 μg/ml, respectively. The coefficients of variance for intraday precision were 1.4% for HA standard (5 μg/ml) and 1.1% for pooled urine, whereas inter-day precision values were 3.2% and 4.9% for HA standard and pooled urine, respectively. Method recovery obtained was 96%–120% for HA solutions containing 2, 3, and 5 μg/ml, demonstrating that precision and recovery of method were satisfactory. Compared to unexposed group, exposed group had significantly more HA. It was found significantly (P < 0.05) higher in urine of exposed workers (32.52 ± 10.91) than unexposed group (16.21 ± 10.14). Conclusion: Sample preparation by LLE is simple and cost-effective for the determination of HA as a biomarker of toluene exposure by HPLC-PDAD. It can be used to detect HA in urine for population exposed to toluene.http://www.environmentmed.org/article.asp?issn=2468-5690;year=2019;volume=4;issue=1;spage=17;epage=22;aulast=YadavHigh-performance liquid chromatographyhippuric acidliquid–liquid extractionphotodiode array detectortoluene exposureurine
collection DOAJ
language English
format Article
sources DOAJ
author Anupa Yadav
Anirban Basu
Amit Chakarbarti
spellingShingle Anupa Yadav
Anirban Basu
Amit Chakarbarti
Method for estimation of hippuric acid as a biomarker of toluene exposure in urine by high-performance liquid chromatography after extraction with ethyl acetate
Environmental Disease
High-performance liquid chromatography
hippuric acid
liquid–liquid extraction
photodiode array detector
toluene exposure
urine
author_facet Anupa Yadav
Anirban Basu
Amit Chakarbarti
author_sort Anupa Yadav
title Method for estimation of hippuric acid as a biomarker of toluene exposure in urine by high-performance liquid chromatography after extraction with ethyl acetate
title_short Method for estimation of hippuric acid as a biomarker of toluene exposure in urine by high-performance liquid chromatography after extraction with ethyl acetate
title_full Method for estimation of hippuric acid as a biomarker of toluene exposure in urine by high-performance liquid chromatography after extraction with ethyl acetate
title_fullStr Method for estimation of hippuric acid as a biomarker of toluene exposure in urine by high-performance liquid chromatography after extraction with ethyl acetate
title_full_unstemmed Method for estimation of hippuric acid as a biomarker of toluene exposure in urine by high-performance liquid chromatography after extraction with ethyl acetate
title_sort method for estimation of hippuric acid as a biomarker of toluene exposure in urine by high-performance liquid chromatography after extraction with ethyl acetate
publisher Wolters Kluwer Medknow Publications
series Environmental Disease
issn 2468-5690
2468-5704
publishDate 2019-01-01
description Aim: This study aimed to establish liquid–liquid extraction (LLE) for estimation of hippuric acid (HA) in urine as a biomarker of the toluene exposure by high-performance liquid chromatography equipped with photodiode array detector (HPLC-PDAD). Method: HA in urine was extracted by LLE and determined by HPLC-PDAD. The operating conditions with HPLC were ODS-2 hypersil column (250 mm × 4.6 mm, 5 μm), 0.1% trifluoro acetic acid (TFA) in acetonitrile and 0.1% TFA in water as mobile phase, 1 ml/min flow rate, and wavelength of 205 nm. The validity of the present method was tested by the estimation of HA in urine samples, collected from toluene-exposed (shoe workers) and unexposed or control subjects. Results: Binary gradient system was used to achieve optimum separation. The analytical curve prepared for HA in aqueous solution in the range of 0.5–10 μg/ml showed determination coefficient value (R2) 0.998. Limit of detection and quantification (LOQ) were 0.46 and 1.53 μg/ml, respectively. The coefficients of variance for intraday precision were 1.4% for HA standard (5 μg/ml) and 1.1% for pooled urine, whereas inter-day precision values were 3.2% and 4.9% for HA standard and pooled urine, respectively. Method recovery obtained was 96%–120% for HA solutions containing 2, 3, and 5 μg/ml, demonstrating that precision and recovery of method were satisfactory. Compared to unexposed group, exposed group had significantly more HA. It was found significantly (P < 0.05) higher in urine of exposed workers (32.52 ± 10.91) than unexposed group (16.21 ± 10.14). Conclusion: Sample preparation by LLE is simple and cost-effective for the determination of HA as a biomarker of toluene exposure by HPLC-PDAD. It can be used to detect HA in urine for population exposed to toluene.
topic High-performance liquid chromatography
hippuric acid
liquid–liquid extraction
photodiode array detector
toluene exposure
urine
url http://www.environmentmed.org/article.asp?issn=2468-5690;year=2019;volume=4;issue=1;spage=17;epage=22;aulast=Yadav
work_keys_str_mv AT anupayadav methodforestimationofhippuricacidasabiomarkeroftolueneexposureinurinebyhighperformanceliquidchromatographyafterextractionwithethylacetate
AT anirbanbasu methodforestimationofhippuricacidasabiomarkeroftolueneexposureinurinebyhighperformanceliquidchromatographyafterextractionwithethylacetate
AT amitchakarbarti methodforestimationofhippuricacidasabiomarkeroftolueneexposureinurinebyhighperformanceliquidchromatographyafterextractionwithethylacetate
_version_ 1725137358230126592