Analytical Control of Pediatric Chemotherapy Preparations with a UV-Raman Automaton: Results After 18 Months of Implementation and Development of A Suitable Method for Low Volume Preparations

In France, control of chemotherapy preparations is highly recommended. Analytical control is a method of choice for identifying and quantifying drugs. Pediatric preparations, which often contain small quantities of drugs and are made in low final volumes were until then not analytically controlled....

Full description

Bibliographic Details
Main Authors: Chouquet Thibaut, Benoit Guy, Morand Karine
Format: Article
Language:English
Published: De Gruyter 2017-11-01
Series:Pharmaceutical Technology in Hospital Pharmacy
Subjects:
Online Access:https://doi.org/10.1515/pthp-2017-0021
id doaj-23f52a6fe1874bc18af1496684d07224
record_format Article
spelling doaj-23f52a6fe1874bc18af1496684d072242021-10-02T17:45:48ZengDe GruyterPharmaceutical Technology in Hospital Pharmacy2365-24112365-242X2017-11-012311712910.1515/pthp-2017-0021Analytical Control of Pediatric Chemotherapy Preparations with a UV-Raman Automaton: Results After 18 Months of Implementation and Development of A Suitable Method for Low Volume PreparationsChouquet Thibaut0Benoit Guy1Morand Karine2Department of pharmacy, Hospital Armand Trousseau (AP-HP), 26 avenue du Dr Arnold Netter, Paris75012, FranceDepartment of pharmacy, Hospital Armand Trousseau (AP-HP), 26 avenue du Dr Arnold Netter, Paris75012, FranceDepartment of pharmacy, Hospital Armand Trousseau (AP-HP), 26 avenue du Dr Arnold Netter, Paris75012, FranceIn France, control of chemotherapy preparations is highly recommended. Analytical control is a method of choice for identifying and quantifying drugs. Pediatric preparations, which often contain small quantities of drugs and are made in low final volumes were until then not analytically controlled. After the development and validation of a new sampling and assaying method for low volume chemotherapy preparations with an UV/Raman automaton (QCPrep +), the quality control results of the preparations intended for the patients were analyzed over a period of eighteen monthshttps://doi.org/10.1515/pthp-2017-0021analytical controlpediatric chemotherapyuv-raman automatonconformityresults analysis
collection DOAJ
language English
format Article
sources DOAJ
author Chouquet Thibaut
Benoit Guy
Morand Karine
spellingShingle Chouquet Thibaut
Benoit Guy
Morand Karine
Analytical Control of Pediatric Chemotherapy Preparations with a UV-Raman Automaton: Results After 18 Months of Implementation and Development of A Suitable Method for Low Volume Preparations
Pharmaceutical Technology in Hospital Pharmacy
analytical control
pediatric chemotherapy
uv-raman automaton
conformity
results analysis
author_facet Chouquet Thibaut
Benoit Guy
Morand Karine
author_sort Chouquet Thibaut
title Analytical Control of Pediatric Chemotherapy Preparations with a UV-Raman Automaton: Results After 18 Months of Implementation and Development of A Suitable Method for Low Volume Preparations
title_short Analytical Control of Pediatric Chemotherapy Preparations with a UV-Raman Automaton: Results After 18 Months of Implementation and Development of A Suitable Method for Low Volume Preparations
title_full Analytical Control of Pediatric Chemotherapy Preparations with a UV-Raman Automaton: Results After 18 Months of Implementation and Development of A Suitable Method for Low Volume Preparations
title_fullStr Analytical Control of Pediatric Chemotherapy Preparations with a UV-Raman Automaton: Results After 18 Months of Implementation and Development of A Suitable Method for Low Volume Preparations
title_full_unstemmed Analytical Control of Pediatric Chemotherapy Preparations with a UV-Raman Automaton: Results After 18 Months of Implementation and Development of A Suitable Method for Low Volume Preparations
title_sort analytical control of pediatric chemotherapy preparations with a uv-raman automaton: results after 18 months of implementation and development of a suitable method for low volume preparations
publisher De Gruyter
series Pharmaceutical Technology in Hospital Pharmacy
issn 2365-2411
2365-242X
publishDate 2017-11-01
description In France, control of chemotherapy preparations is highly recommended. Analytical control is a method of choice for identifying and quantifying drugs. Pediatric preparations, which often contain small quantities of drugs and are made in low final volumes were until then not analytically controlled. After the development and validation of a new sampling and assaying method for low volume chemotherapy preparations with an UV/Raman automaton (QCPrep +), the quality control results of the preparations intended for the patients were analyzed over a period of eighteen months
topic analytical control
pediatric chemotherapy
uv-raman automaton
conformity
results analysis
url https://doi.org/10.1515/pthp-2017-0021
work_keys_str_mv AT chouquetthibaut analyticalcontrolofpediatricchemotherapypreparationswithauvramanautomatonresultsafter18monthsofimplementationanddevelopmentofasuitablemethodforlowvolumepreparations
AT benoitguy analyticalcontrolofpediatricchemotherapypreparationswithauvramanautomatonresultsafter18monthsofimplementationanddevelopmentofasuitablemethodforlowvolumepreparations
AT morandkarine analyticalcontrolofpediatricchemotherapypreparationswithauvramanautomatonresultsafter18monthsofimplementationanddevelopmentofasuitablemethodforlowvolumepreparations
_version_ 1716850530710454272