Improving energy performance power station of ship with integrated electric propulsion
The article presents the method of calculating the power plant fuel consumption on the basis of diesel-generating installation (DGI) with variable speed for ships with integrated electric propulsion. Application DGI with variable speed allows saving fuel and therefore reducing harmful emissions into...
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
EDP Sciences
2017-01-01
|
Series: | MATEC Web of Conferences |
Online Access: | https://doi.org/10.1051/matecconf/201710814002 |
Summary: | The article presents the method of calculating the power plant fuel consumption on the basis of diesel-generating installation (DGI) with variable speed for ships with integrated electric propulsion. Application DGI with variable speed allows saving fuel and therefore reducing harmful emissions into the atmosphere. In the paper calculated the fuel efficiency of unified power station on the basis of a variable speed DGI power of 1000 kW. |
---|---|