Technical considerations for medical device manufacturers when designing gastrostomy tubes (G-tubes) using the new ISO 80369-3 connector.

<h4>Background</h4>Gastrostomy tubes (G-tubes) are typically used when people cannot eat food by mouth. The connector section that allows G-tubes to connect to other devices, such as feeding sets or syringes, has been modified on some of the devices to reduce misconnections in hospital s...

Full description

Bibliographic Details
Main Authors: Suvajyoti Guha, Alexander Herman, Luke Herbertson, Mark J Antonino, Joshua S Silverstein, Jeffrey Cooper, Matthew R Myers
Format: Article
Language:English
Published: Public Library of Science (PLoS) 2020-01-01
Series:PLoS ONE
Online Access:https://doi.org/10.1371/journal.pone.0236644
id doaj-22660a8448094829a18ddeee32e7b5aa
record_format Article
spelling doaj-22660a8448094829a18ddeee32e7b5aa2021-03-04T11:15:34ZengPublic Library of Science (PLoS)PLoS ONE1932-62032020-01-01157e023664410.1371/journal.pone.0236644Technical considerations for medical device manufacturers when designing gastrostomy tubes (G-tubes) using the new ISO 80369-3 connector.Suvajyoti GuhaAlexander HermanLuke HerbertsonMark J AntoninoJoshua S SilversteinJeffrey CooperMatthew R Myers<h4>Background</h4>Gastrostomy tubes (G-tubes) are typically used when people cannot eat food by mouth. The connector section that allows G-tubes to connect to other devices, such as feeding sets or syringes, has been modified on some of the devices to reduce misconnections in hospital settings. The narrow internal diameter of the new connector, standardized under ISO 80369-3, has caused some users to express concern about a reduced flow rate. Previous studies performed on commercial devices determined that it was not conclusive how much the ISO 80369-3 connector contributed towards the reduced flow rate, because when manufacturers designed these new connector-based devices, they often changed other geometric variables (such as distal tube diameter, or length) at the same time. Thus, it became difficult isolating the effect of the connector from other geometric variables.<h4>Method</h4>The key objective of this study was to investigate how different design variables impacted the flow rate through the G-tubes. 3D-printed devices were used to assess the geometric parameters in a systematic manner. Commercial diets and Newtonian analog fluids with matched viscosities were used for testing.<h4>Results</h4>The flow path length of the "transition section" encompassing the standardized ISO 80369-3 connector in the new devices was found to cause reduced flow. Additionally, results showed that a shortened (≤ 10 mm) transition section, along with a 10% increase in the distal inner diameter of large bore devices (e.g., 24 Fr), can restore flow rates to levels consistent with the previous devices prior to the connector standardization.<h4>Conclusions</h4>The strategy for restoring flow rates to previous levels may help alleviate concerns raised by multiple stakeholders such as health care professionals, patients, caregivers and device manufacturers. In addition, the approach proposed here can be used as a tool for designing future G-tube devices.https://doi.org/10.1371/journal.pone.0236644
collection DOAJ
language English
format Article
sources DOAJ
author Suvajyoti Guha
Alexander Herman
Luke Herbertson
Mark J Antonino
Joshua S Silverstein
Jeffrey Cooper
Matthew R Myers
spellingShingle Suvajyoti Guha
Alexander Herman
Luke Herbertson
Mark J Antonino
Joshua S Silverstein
Jeffrey Cooper
Matthew R Myers
Technical considerations for medical device manufacturers when designing gastrostomy tubes (G-tubes) using the new ISO 80369-3 connector.
PLoS ONE
author_facet Suvajyoti Guha
Alexander Herman
Luke Herbertson
Mark J Antonino
Joshua S Silverstein
Jeffrey Cooper
Matthew R Myers
author_sort Suvajyoti Guha
title Technical considerations for medical device manufacturers when designing gastrostomy tubes (G-tubes) using the new ISO 80369-3 connector.
title_short Technical considerations for medical device manufacturers when designing gastrostomy tubes (G-tubes) using the new ISO 80369-3 connector.
title_full Technical considerations for medical device manufacturers when designing gastrostomy tubes (G-tubes) using the new ISO 80369-3 connector.
title_fullStr Technical considerations for medical device manufacturers when designing gastrostomy tubes (G-tubes) using the new ISO 80369-3 connector.
title_full_unstemmed Technical considerations for medical device manufacturers when designing gastrostomy tubes (G-tubes) using the new ISO 80369-3 connector.
title_sort technical considerations for medical device manufacturers when designing gastrostomy tubes (g-tubes) using the new iso 80369-3 connector.
publisher Public Library of Science (PLoS)
series PLoS ONE
issn 1932-6203
publishDate 2020-01-01
description <h4>Background</h4>Gastrostomy tubes (G-tubes) are typically used when people cannot eat food by mouth. The connector section that allows G-tubes to connect to other devices, such as feeding sets or syringes, has been modified on some of the devices to reduce misconnections in hospital settings. The narrow internal diameter of the new connector, standardized under ISO 80369-3, has caused some users to express concern about a reduced flow rate. Previous studies performed on commercial devices determined that it was not conclusive how much the ISO 80369-3 connector contributed towards the reduced flow rate, because when manufacturers designed these new connector-based devices, they often changed other geometric variables (such as distal tube diameter, or length) at the same time. Thus, it became difficult isolating the effect of the connector from other geometric variables.<h4>Method</h4>The key objective of this study was to investigate how different design variables impacted the flow rate through the G-tubes. 3D-printed devices were used to assess the geometric parameters in a systematic manner. Commercial diets and Newtonian analog fluids with matched viscosities were used for testing.<h4>Results</h4>The flow path length of the "transition section" encompassing the standardized ISO 80369-3 connector in the new devices was found to cause reduced flow. Additionally, results showed that a shortened (≤ 10 mm) transition section, along with a 10% increase in the distal inner diameter of large bore devices (e.g., 24 Fr), can restore flow rates to levels consistent with the previous devices prior to the connector standardization.<h4>Conclusions</h4>The strategy for restoring flow rates to previous levels may help alleviate concerns raised by multiple stakeholders such as health care professionals, patients, caregivers and device manufacturers. In addition, the approach proposed here can be used as a tool for designing future G-tube devices.
url https://doi.org/10.1371/journal.pone.0236644
work_keys_str_mv AT suvajyotiguha technicalconsiderationsformedicaldevicemanufacturerswhendesigninggastrostomytubesgtubesusingthenewiso803693connector
AT alexanderherman technicalconsiderationsformedicaldevicemanufacturerswhendesigninggastrostomytubesgtubesusingthenewiso803693connector
AT lukeherbertson technicalconsiderationsformedicaldevicemanufacturerswhendesigninggastrostomytubesgtubesusingthenewiso803693connector
AT markjantonino technicalconsiderationsformedicaldevicemanufacturerswhendesigninggastrostomytubesgtubesusingthenewiso803693connector
AT joshuassilverstein technicalconsiderationsformedicaldevicemanufacturerswhendesigninggastrostomytubesgtubesusingthenewiso803693connector
AT jeffreycooper technicalconsiderationsformedicaldevicemanufacturerswhendesigninggastrostomytubesgtubesusingthenewiso803693connector
AT matthewrmyers technicalconsiderationsformedicaldevicemanufacturerswhendesigninggastrostomytubesgtubesusingthenewiso803693connector
_version_ 1714804240711417856