Alternative manometric method of calibration of pressure transducers for invasive hemodynamic monitoring
<p><span style="font-family: Verdana,Arial,Helvetica,sans-serif; font-size: small;"><strong>Introduction:</strong> Transducer calibration is very important for the accurate measurement of pressures during invasive hemodynamic monitoring of patients requiring close o...
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | Spanish |
Published: |
Centro Nacional de Información de Ciencias Médicas. Editorial de Ciencias Médicas (ECIMED)
2017-05-01
|
Series: | Revista Cubana de Anestesiología y Reanimación |
Subjects: | |
Online Access: | http://revanestesia.sld.cu/index.php/anestRean/article/view/152 |
id |
doaj-2246f8c1e8ba49b68b3f46a5060de9f1 |
---|---|
record_format |
Article |
spelling |
doaj-2246f8c1e8ba49b68b3f46a5060de9f12020-11-29T03:49:44ZspaCentro Nacional de Información de Ciencias Médicas. Editorial de Ciencias Médicas (ECIMED)Revista Cubana de Anestesiología y Reanimación1726-67182017-05-01162151Alternative manometric method of calibration of pressure transducers for invasive hemodynamic monitoringAlberto Hernández González0Lázaro Edel Sánchez Escalona1Caridad de Dios Soler Morejón2Mirtha López Ramírez3Agustín Mulet Gómez4Hospital Clínico Quirúrgico "Hermanos Ameijeiras". La HabanaHospital Clínico Quirúrgico "Hermanos Ameijeiras". La HabanaHospital Clínico Quirúrgico "Hermanos Ameijeiras". La HabanaHospital Clínico Quirúrgico "Hermanos Ameijeiras". La HabanaHospital Clínico Quirúrgico "Hermanos Ameijeiras". La Habana<p><span style="font-family: Verdana,Arial,Helvetica,sans-serif; font-size: small;"><strong>Introduction:</strong> Transducer calibration is very important for the accurate measurement of pressures during invasive hemodynamic monitoring of patients requiring close observation in the primary care units and in the operating room. <br /> </span><span style="font-family: Verdana,Arial,Helvetica,sans-serif; font-size: small;"><strong>Objective</strong>: To develop and validate a method of calibration of pressure transducers, which is simple, efficient and low-cost. <br /> </span><span style="font-family: Verdana,Arial,Helvetica,sans-serif; font-size: small;"><strong>Methods: </strong> An alternative manometric method, based on Pascal's law, was developed for the calibration of pressure transducers during invasive hemodynamic monitoring performed at the intensive care unit of the cardiovascular surgery department at Hermanos Ameijeiras Clinical-Surgical Hospital. This method was validated by its comparison with the recommended standard in a total of 215 patients who required invasive hemodynamic monitoring between January and June 2015. <br /> </span><span style="font-family: Verdana,Arial,Helvetica,sans-serif; font-size: small;"><strong>Results</strong>: With the alternative manometric method created, the same result was obtained as with the hydraulic method recommended by the literature. <br /> </span><span style="font-family: Verdana,Arial,Helvetica,sans-serif; font-size: small;"><strong>Conclusions:</strong> The alternative method created is accurate, efficient and cost-effective. </span></p>http://revanestesia.sld.cu/index.php/anestRean/article/view/152transductor de presiónmonitorización hemodinámica invasivacalibración de transductores. |
collection |
DOAJ |
language |
Spanish |
format |
Article |
sources |
DOAJ |
author |
Alberto Hernández González Lázaro Edel Sánchez Escalona Caridad de Dios Soler Morejón Mirtha López Ramírez Agustín Mulet Gómez |
spellingShingle |
Alberto Hernández González Lázaro Edel Sánchez Escalona Caridad de Dios Soler Morejón Mirtha López Ramírez Agustín Mulet Gómez Alternative manometric method of calibration of pressure transducers for invasive hemodynamic monitoring Revista Cubana de Anestesiología y Reanimación transductor de presión monitorización hemodinámica invasiva calibración de transductores. |
author_facet |
Alberto Hernández González Lázaro Edel Sánchez Escalona Caridad de Dios Soler Morejón Mirtha López Ramírez Agustín Mulet Gómez |
author_sort |
Alberto Hernández González |
title |
Alternative manometric method of calibration of pressure transducers for invasive hemodynamic monitoring |
title_short |
Alternative manometric method of calibration of pressure transducers for invasive hemodynamic monitoring |
title_full |
Alternative manometric method of calibration of pressure transducers for invasive hemodynamic monitoring |
title_fullStr |
Alternative manometric method of calibration of pressure transducers for invasive hemodynamic monitoring |
title_full_unstemmed |
Alternative manometric method of calibration of pressure transducers for invasive hemodynamic monitoring |
title_sort |
alternative manometric method of calibration of pressure transducers for invasive hemodynamic monitoring |
publisher |
Centro Nacional de Información de Ciencias Médicas. Editorial de Ciencias Médicas (ECIMED) |
series |
Revista Cubana de Anestesiología y Reanimación |
issn |
1726-6718 |
publishDate |
2017-05-01 |
description |
<p><span style="font-family: Verdana,Arial,Helvetica,sans-serif; font-size: small;"><strong>Introduction:</strong> Transducer calibration is very important for the accurate measurement of pressures during invasive hemodynamic monitoring of patients requiring close observation in the primary care units and in the operating room. <br /> </span><span style="font-family: Verdana,Arial,Helvetica,sans-serif; font-size: small;"><strong>Objective</strong>: To develop and validate a method of calibration of pressure transducers, which is simple, efficient and low-cost. <br /> </span><span style="font-family: Verdana,Arial,Helvetica,sans-serif; font-size: small;"><strong>Methods: </strong> An alternative manometric method, based on Pascal's law, was developed for the calibration of pressure transducers during invasive hemodynamic monitoring performed at the intensive care unit of the cardiovascular surgery department at Hermanos Ameijeiras Clinical-Surgical Hospital. This method was validated by its comparison with the recommended standard in a total of 215 patients who required invasive hemodynamic monitoring between January and June 2015. <br /> </span><span style="font-family: Verdana,Arial,Helvetica,sans-serif; font-size: small;"><strong>Results</strong>: With the alternative manometric method created, the same result was obtained as with the hydraulic method recommended by the literature. <br /> </span><span style="font-family: Verdana,Arial,Helvetica,sans-serif; font-size: small;"><strong>Conclusions:</strong> The alternative method created is accurate, efficient and cost-effective. </span></p> |
topic |
transductor de presión monitorización hemodinámica invasiva calibración de transductores. |
url |
http://revanestesia.sld.cu/index.php/anestRean/article/view/152 |
work_keys_str_mv |
AT albertohernandezgonzalez alternativemanometricmethodofcalibrationofpressuretransducersforinvasivehemodynamicmonitoring AT lazaroedelsanchezescalona alternativemanometricmethodofcalibrationofpressuretransducersforinvasivehemodynamicmonitoring AT caridaddediossolermorejon alternativemanometricmethodofcalibrationofpressuretransducersforinvasivehemodynamicmonitoring AT mirthalopezramirez alternativemanometricmethodofcalibrationofpressuretransducersforinvasivehemodynamicmonitoring AT agustinmuletgomez alternativemanometricmethodofcalibrationofpressuretransducersforinvasivehemodynamicmonitoring |
_version_ |
1724412503024205824 |