WATER-PERFUSED HIGH-RESOLUTION ANORECTAL MANOMETRY (HRAM-WP): THE FIRST BRAZILIAN STUDY
ABSTRACT BACKGROUND: High resolution anorectal manometry (HRAM-WP) allows more simplified, objective, and uniform data acquisition and interpretation of the test results. OBJECTIVE: To validate a HRAM under water perfusion (Alacer Biomédica) with a 24-channel probe and to compare the results of...
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Instituto Brasileiro de Estudos e Pesquisas de Gastroenterologia (IBEPEGE)
2018-08-01
|
Series: | Arquivos de Gastroenterologia |
Subjects: | |
Online Access: | http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0004-28032018005002101&lng=en&tlng=en |
id |
doaj-2180637147bb42a181e299056f710d01 |
---|---|
record_format |
Article |
spelling |
doaj-2180637147bb42a181e299056f710d012020-11-25T00:46:08ZengInstituto Brasileiro de Estudos e Pesquisas de Gastroenterologia (IBEPEGE)Arquivos de Gastroenterologia1678-42192018-08-01010.1590/s0004-2803.201800000-38S0004-28032018005002101WATER-PERFUSED HIGH-RESOLUTION ANORECTAL MANOMETRY (HRAM-WP): THE FIRST BRAZILIAN STUDYRicardo Guilherme VIEBIGJanaina Tomiye Yamakata FRANCOSergio Viebig ARAUJODaniel GUALBERTOABSTRACT BACKGROUND: High resolution anorectal manometry (HRAM-WP) allows more simplified, objective, and uniform data acquisition and interpretation of the test results. OBJECTIVE: To validate a HRAM under water perfusion (Alacer Biomédica) with a 24-channel probe and to compare the results of anorectal manometry with other systems. METHODS: Individuals without critical evacuation disorders were selected. Patients with incontinence, anal surgery, dyssynergia or sphincter injury were excluded. The test was performed with an Alacer Biomédica 24 channel manometry system under water perfusion, with a probe configured with 6 levels of 4 radial channels, separated from each other by 0.8 mm. The mean pressures for the functional channel were determined, in states of rest (RMP), contention effort (CMP) and evacuation effort (EEMP). The pressure extension of the sphincter was also tabulated in cm. The results were compared with those available in recent literature. RESULTS: Fifty patients were studied (20 men; 30 women). Overall, the following results were obtained: the RMP was 76.9±3.0 mmHg, the CMP was 194.2±9.4 mmHg, and EEMP was 88.2±3.7 mmHg. When classified according to the gender, for men: RMP was 72.2±3.0 mmHg, CMP was 229.5±17 mmHg, and EEMP was 91.4±7.0. For women, RMP was 79.8±4.0 mmHg, CMP was 170.7±8, and EEMP was 86.1±4.3 mmHg. The sphincter gauge extension for both genders was 3.1±0.09 cm (men 3.3±0.1; women 3.0±0.1). DISCUSSION: Studying HRAM-WP has become much easier. Non-mobilization of the sensor causes less discomfort and artefacts with a lower assessment time. In this study, small differential values between both sexes during rest were observed, highlighting a greater containment force in men. No difference in sphincter extension was noted. The results of this study are consistent with that of existing reports and with those obtained using solid state probes. CONCLUSION: The perfusion system yielded results similar to that of solid state systems. Further studies to evaluate parameters with respect to pelvic dyssynergia and incontinence need to be conducted. Additionally, to determine if the vector volume can furnish new information in terms of functional and anatomical aspects.http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0004-28032018005002101&lng=en&tlng=enAnal canal, anatomy & histologyManometry, trendsInfusion pumps |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Ricardo Guilherme VIEBIG Janaina Tomiye Yamakata FRANCO Sergio Viebig ARAUJO Daniel GUALBERTO |
spellingShingle |
Ricardo Guilherme VIEBIG Janaina Tomiye Yamakata FRANCO Sergio Viebig ARAUJO Daniel GUALBERTO WATER-PERFUSED HIGH-RESOLUTION ANORECTAL MANOMETRY (HRAM-WP): THE FIRST BRAZILIAN STUDY Arquivos de Gastroenterologia Anal canal, anatomy & histology Manometry, trends Infusion pumps |
author_facet |
Ricardo Guilherme VIEBIG Janaina Tomiye Yamakata FRANCO Sergio Viebig ARAUJO Daniel GUALBERTO |
author_sort |
Ricardo Guilherme VIEBIG |
title |
WATER-PERFUSED HIGH-RESOLUTION ANORECTAL MANOMETRY (HRAM-WP): THE FIRST BRAZILIAN STUDY |
title_short |
WATER-PERFUSED HIGH-RESOLUTION ANORECTAL MANOMETRY (HRAM-WP): THE FIRST BRAZILIAN STUDY |
title_full |
WATER-PERFUSED HIGH-RESOLUTION ANORECTAL MANOMETRY (HRAM-WP): THE FIRST BRAZILIAN STUDY |
title_fullStr |
WATER-PERFUSED HIGH-RESOLUTION ANORECTAL MANOMETRY (HRAM-WP): THE FIRST BRAZILIAN STUDY |
title_full_unstemmed |
WATER-PERFUSED HIGH-RESOLUTION ANORECTAL MANOMETRY (HRAM-WP): THE FIRST BRAZILIAN STUDY |
title_sort |
water-perfused high-resolution anorectal manometry (hram-wp): the first brazilian study |
publisher |
Instituto Brasileiro de Estudos e Pesquisas de Gastroenterologia (IBEPEGE) |
series |
Arquivos de Gastroenterologia |
issn |
1678-4219 |
publishDate |
2018-08-01 |
description |
ABSTRACT BACKGROUND: High resolution anorectal manometry (HRAM-WP) allows more simplified, objective, and uniform data acquisition and interpretation of the test results. OBJECTIVE: To validate a HRAM under water perfusion (Alacer Biomédica) with a 24-channel probe and to compare the results of anorectal manometry with other systems. METHODS: Individuals without critical evacuation disorders were selected. Patients with incontinence, anal surgery, dyssynergia or sphincter injury were excluded. The test was performed with an Alacer Biomédica 24 channel manometry system under water perfusion, with a probe configured with 6 levels of 4 radial channels, separated from each other by 0.8 mm. The mean pressures for the functional channel were determined, in states of rest (RMP), contention effort (CMP) and evacuation effort (EEMP). The pressure extension of the sphincter was also tabulated in cm. The results were compared with those available in recent literature. RESULTS: Fifty patients were studied (20 men; 30 women). Overall, the following results were obtained: the RMP was 76.9±3.0 mmHg, the CMP was 194.2±9.4 mmHg, and EEMP was 88.2±3.7 mmHg. When classified according to the gender, for men: RMP was 72.2±3.0 mmHg, CMP was 229.5±17 mmHg, and EEMP was 91.4±7.0. For women, RMP was 79.8±4.0 mmHg, CMP was 170.7±8, and EEMP was 86.1±4.3 mmHg. The sphincter gauge extension for both genders was 3.1±0.09 cm (men 3.3±0.1; women 3.0±0.1). DISCUSSION: Studying HRAM-WP has become much easier. Non-mobilization of the sensor causes less discomfort and artefacts with a lower assessment time. In this study, small differential values between both sexes during rest were observed, highlighting a greater containment force in men. No difference in sphincter extension was noted. The results of this study are consistent with that of existing reports and with those obtained using solid state probes. CONCLUSION: The perfusion system yielded results similar to that of solid state systems. Further studies to evaluate parameters with respect to pelvic dyssynergia and incontinence need to be conducted. Additionally, to determine if the vector volume can furnish new information in terms of functional and anatomical aspects. |
topic |
Anal canal, anatomy & histology Manometry, trends Infusion pumps |
url |
http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0004-28032018005002101&lng=en&tlng=en |
work_keys_str_mv |
AT ricardoguilhermeviebig waterperfusedhighresolutionanorectalmanometryhramwpthefirstbrazilianstudy AT janainatomiyeyamakatafranco waterperfusedhighresolutionanorectalmanometryhramwpthefirstbrazilianstudy AT sergioviebigaraujo waterperfusedhighresolutionanorectalmanometryhramwpthefirstbrazilianstudy AT danielgualberto waterperfusedhighresolutionanorectalmanometryhramwpthefirstbrazilianstudy |
_version_ |
1725266785636188160 |