WATER-PERFUSED HIGH-RESOLUTION ANORECTAL MANOMETRY (HRAM-WP): THE FIRST BRAZILIAN STUDY

ABSTRACT BACKGROUND: High resolution anorectal manometry (HRAM-WP) allows more simplified, objective, and uniform data acquisition and interpretation of the test results. OBJECTIVE: To validate a HRAM under water perfusion (Alacer Biomédica) with a 24-channel probe and to compare the results of...

Full description

Bibliographic Details
Main Authors: Ricardo Guilherme VIEBIG, Janaina Tomiye Yamakata FRANCO, Sergio Viebig ARAUJO, Daniel GUALBERTO
Format: Article
Language:English
Published: Instituto Brasileiro de Estudos e Pesquisas de Gastroenterologia (IBEPEGE) 2018-08-01
Series:Arquivos de Gastroenterologia
Subjects:
Online Access:http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0004-28032018005002101&lng=en&tlng=en
id doaj-2180637147bb42a181e299056f710d01
record_format Article
spelling doaj-2180637147bb42a181e299056f710d012020-11-25T00:46:08ZengInstituto Brasileiro de Estudos e Pesquisas de Gastroenterologia (IBEPEGE)Arquivos de Gastroenterologia1678-42192018-08-01010.1590/s0004-2803.201800000-38S0004-28032018005002101WATER-PERFUSED HIGH-RESOLUTION ANORECTAL MANOMETRY (HRAM-WP): THE FIRST BRAZILIAN STUDYRicardo Guilherme VIEBIGJanaina Tomiye Yamakata FRANCOSergio Viebig ARAUJODaniel GUALBERTOABSTRACT BACKGROUND: High resolution anorectal manometry (HRAM-WP) allows more simplified, objective, and uniform data acquisition and interpretation of the test results. OBJECTIVE: To validate a HRAM under water perfusion (Alacer Biomédica) with a 24-channel probe and to compare the results of anorectal manometry with other systems. METHODS: Individuals without critical evacuation disorders were selected. Patients with incontinence, anal surgery, dyssynergia or sphincter injury were excluded. The test was performed with an Alacer Biomédica 24 channel manometry system under water perfusion, with a probe configured with 6 levels of 4 radial channels, separated from each other by 0.8 mm. The mean pressures for the functional channel were determined, in states of rest (RMP), contention effort (CMP) and evacuation effort (EEMP). The pressure extension of the sphincter was also tabulated in cm. The results were compared with those available in recent literature. RESULTS: Fifty patients were studied (20 men; 30 women). Overall, the following results were obtained: the RMP was 76.9±3.0 mmHg, the CMP was 194.2±9.4 mmHg, and EEMP was 88.2±3.7 mmHg. When classified according to the gender, for men: RMP was 72.2±3.0 mmHg, CMP was 229.5±17 mmHg, and EEMP was 91.4±7.0. For women, RMP was 79.8±4.0 mmHg, CMP was 170.7±8, and EEMP was 86.1±4.3 mmHg. The sphincter gauge extension for both genders was 3.1±0.09 cm (men 3.3±0.1; women 3.0±0.1). DISCUSSION: Studying HRAM-WP has become much easier. Non-mobilization of the sensor causes less discomfort and artefacts with a lower assessment time. In this study, small differential values between both sexes during rest were observed, highlighting a greater containment force in men. No difference in sphincter extension was noted. The results of this study are consistent with that of existing reports and with those obtained using solid state probes. CONCLUSION: The perfusion system yielded results similar to that of solid state systems. Further studies to evaluate parameters with respect to pelvic dyssynergia and incontinence need to be conducted. Additionally, to determine if the vector volume can furnish new information in terms of functional and anatomical aspects.http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0004-28032018005002101&lng=en&tlng=enAnal canal, anatomy & histologyManometry, trendsInfusion pumps
collection DOAJ
language English
format Article
sources DOAJ
author Ricardo Guilherme VIEBIG
Janaina Tomiye Yamakata FRANCO
Sergio Viebig ARAUJO
Daniel GUALBERTO
spellingShingle Ricardo Guilherme VIEBIG
Janaina Tomiye Yamakata FRANCO
Sergio Viebig ARAUJO
Daniel GUALBERTO
WATER-PERFUSED HIGH-RESOLUTION ANORECTAL MANOMETRY (HRAM-WP): THE FIRST BRAZILIAN STUDY
Arquivos de Gastroenterologia
Anal canal, anatomy & histology
Manometry, trends
Infusion pumps
author_facet Ricardo Guilherme VIEBIG
Janaina Tomiye Yamakata FRANCO
Sergio Viebig ARAUJO
Daniel GUALBERTO
author_sort Ricardo Guilherme VIEBIG
title WATER-PERFUSED HIGH-RESOLUTION ANORECTAL MANOMETRY (HRAM-WP): THE FIRST BRAZILIAN STUDY
title_short WATER-PERFUSED HIGH-RESOLUTION ANORECTAL MANOMETRY (HRAM-WP): THE FIRST BRAZILIAN STUDY
title_full WATER-PERFUSED HIGH-RESOLUTION ANORECTAL MANOMETRY (HRAM-WP): THE FIRST BRAZILIAN STUDY
title_fullStr WATER-PERFUSED HIGH-RESOLUTION ANORECTAL MANOMETRY (HRAM-WP): THE FIRST BRAZILIAN STUDY
title_full_unstemmed WATER-PERFUSED HIGH-RESOLUTION ANORECTAL MANOMETRY (HRAM-WP): THE FIRST BRAZILIAN STUDY
title_sort water-perfused high-resolution anorectal manometry (hram-wp): the first brazilian study
publisher Instituto Brasileiro de Estudos e Pesquisas de Gastroenterologia (IBEPEGE)
series Arquivos de Gastroenterologia
issn 1678-4219
publishDate 2018-08-01
description ABSTRACT BACKGROUND: High resolution anorectal manometry (HRAM-WP) allows more simplified, objective, and uniform data acquisition and interpretation of the test results. OBJECTIVE: To validate a HRAM under water perfusion (Alacer Biomédica) with a 24-channel probe and to compare the results of anorectal manometry with other systems. METHODS: Individuals without critical evacuation disorders were selected. Patients with incontinence, anal surgery, dyssynergia or sphincter injury were excluded. The test was performed with an Alacer Biomédica 24 channel manometry system under water perfusion, with a probe configured with 6 levels of 4 radial channels, separated from each other by 0.8 mm. The mean pressures for the functional channel were determined, in states of rest (RMP), contention effort (CMP) and evacuation effort (EEMP). The pressure extension of the sphincter was also tabulated in cm. The results were compared with those available in recent literature. RESULTS: Fifty patients were studied (20 men; 30 women). Overall, the following results were obtained: the RMP was 76.9±3.0 mmHg, the CMP was 194.2±9.4 mmHg, and EEMP was 88.2±3.7 mmHg. When classified according to the gender, for men: RMP was 72.2±3.0 mmHg, CMP was 229.5±17 mmHg, and EEMP was 91.4±7.0. For women, RMP was 79.8±4.0 mmHg, CMP was 170.7±8, and EEMP was 86.1±4.3 mmHg. The sphincter gauge extension for both genders was 3.1±0.09 cm (men 3.3±0.1; women 3.0±0.1). DISCUSSION: Studying HRAM-WP has become much easier. Non-mobilization of the sensor causes less discomfort and artefacts with a lower assessment time. In this study, small differential values between both sexes during rest were observed, highlighting a greater containment force in men. No difference in sphincter extension was noted. The results of this study are consistent with that of existing reports and with those obtained using solid state probes. CONCLUSION: The perfusion system yielded results similar to that of solid state systems. Further studies to evaluate parameters with respect to pelvic dyssynergia and incontinence need to be conducted. Additionally, to determine if the vector volume can furnish new information in terms of functional and anatomical aspects.
topic Anal canal, anatomy & histology
Manometry, trends
Infusion pumps
url http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0004-28032018005002101&lng=en&tlng=en
work_keys_str_mv AT ricardoguilhermeviebig waterperfusedhighresolutionanorectalmanometryhramwpthefirstbrazilianstudy
AT janainatomiyeyamakatafranco waterperfusedhighresolutionanorectalmanometryhramwpthefirstbrazilianstudy
AT sergioviebigaraujo waterperfusedhighresolutionanorectalmanometryhramwpthefirstbrazilianstudy
AT danielgualberto waterperfusedhighresolutionanorectalmanometryhramwpthefirstbrazilianstudy
_version_ 1725266785636188160