Patient setup variations in computed tomography-based treatment planning for left-sided breast cancer using electronic portal images

Background and Aim: This study deals with isocentric variations along with the setup reproducibility and determines the random and systematic errors in a cohort of 25 (females) left-sided breast cancer patients treated with megavoltage X-rays using an online electronic portal imaging (EPI) protocol....

Full description

Bibliographic Details
Main Authors: Sachin Taneja, Deboleena Mukherjee, Kirti Tyagi
Format: Article
Language:English
Published: Wolters Kluwer Medknow Publications 2020-01-01
Series:Journal of Marine Medical Society
Subjects:
Online Access:http://www.marinemedicalsociety.in/article.asp?issn=0975-3605;year=2020;volume=22;issue=1;spage=30;epage=34;aulast=Taneja
id doaj-216b9dd757af4a4cb14e30d6d843454c
record_format Article
spelling doaj-216b9dd757af4a4cb14e30d6d843454c2020-11-25T01:59:38ZengWolters Kluwer Medknow PublicationsJournal of Marine Medical Society0975-36052020-01-01221303410.4103/jmms.jmms_70_19Patient setup variations in computed tomography-based treatment planning for left-sided breast cancer using electronic portal imagesSachin TanejaDeboleena MukherjeeKirti TyagiBackground and Aim: This study deals with isocentric variations along with the setup reproducibility and determines the random and systematic errors in a cohort of 25 (females) left-sided breast cancer patients treated with megavoltage X-rays using an online electronic portal imaging (EPI) protocol. Materials and Methods: This is a hospital-based cross-sectional observational study which was carried out on 25 female patients of carcinoma breast (left sided) who had undergone modified radical mastectomy. After completion of the planned chemotherapy, all patients underwent virtual three-dimensional (3D) computed tomography (CT) simulation, and an external beam radiotherapy treatment was planned on these 3D CT images on a treatment planning system (TPS) using two (coplanar)/conventional tangential fields for a total dose of 50 Gy in 25 fractions. Analysis of 150 EPIs determined changes in the treatment fields during setup of these 25 patients. The online assessment included setup deviations in all the three directions (anteroposterior [AP], superoinferior [SI], and mediolateral [ML]) and variations in central lung distance (CLD) during the first three fractions. Results: Random errors ranged from 1 to 5 mm for the chest wall (medial and lateral) tangential treatments and 1 mm for the anterior supraclavicular nodal field. Systematic errors ranged from 2.5 to 4.5 mm in the AP direction for the tangential fields and from 2.5 to 7.5 mm in the SI and Mediolateral directions for the anterior supraclavicular nodal field. For 25 (left-sided) patients, the CLD (TPS) was 20–30 mm, CLD (EPIs) was 25–40 mm showing variations of 5–10 mm, V20 was 1.0–6.0 Gy, maximum total lung dose was 43 Gy, V30 was 2.0–4.0 Gy, maximum heart dose was 52 Gy, and maximum spine dose was 45 Gy. Conclusions: Online assessment of patient position with matching of EPIs with digitally reconstructed radiographs is a useful method in evaluation of interfraction reproducibility of tangential fields in breast irradiation, thereby improving upon the quality of treatment delivery for our patient population.http://www.marinemedicalsociety.in/article.asp?issn=0975-3605;year=2020;volume=22;issue=1;spage=30;epage=34;aulast=Tanejacentral lung distancedigitally reconstructed radiographselectronic portal imagingrandom errorssetup reproducibilitysystematic errors/setup errorsthree-dimensional computerized tomography images
collection DOAJ
language English
format Article
sources DOAJ
author Sachin Taneja
Deboleena Mukherjee
Kirti Tyagi
spellingShingle Sachin Taneja
Deboleena Mukherjee
Kirti Tyagi
Patient setup variations in computed tomography-based treatment planning for left-sided breast cancer using electronic portal images
Journal of Marine Medical Society
central lung distance
digitally reconstructed radiographs
electronic portal imaging
random errors
setup reproducibility
systematic errors/setup errors
three-dimensional computerized tomography images
author_facet Sachin Taneja
Deboleena Mukherjee
Kirti Tyagi
author_sort Sachin Taneja
title Patient setup variations in computed tomography-based treatment planning for left-sided breast cancer using electronic portal images
title_short Patient setup variations in computed tomography-based treatment planning for left-sided breast cancer using electronic portal images
title_full Patient setup variations in computed tomography-based treatment planning for left-sided breast cancer using electronic portal images
title_fullStr Patient setup variations in computed tomography-based treatment planning for left-sided breast cancer using electronic portal images
title_full_unstemmed Patient setup variations in computed tomography-based treatment planning for left-sided breast cancer using electronic portal images
title_sort patient setup variations in computed tomography-based treatment planning for left-sided breast cancer using electronic portal images
publisher Wolters Kluwer Medknow Publications
series Journal of Marine Medical Society
issn 0975-3605
publishDate 2020-01-01
description Background and Aim: This study deals with isocentric variations along with the setup reproducibility and determines the random and systematic errors in a cohort of 25 (females) left-sided breast cancer patients treated with megavoltage X-rays using an online electronic portal imaging (EPI) protocol. Materials and Methods: This is a hospital-based cross-sectional observational study which was carried out on 25 female patients of carcinoma breast (left sided) who had undergone modified radical mastectomy. After completion of the planned chemotherapy, all patients underwent virtual three-dimensional (3D) computed tomography (CT) simulation, and an external beam radiotherapy treatment was planned on these 3D CT images on a treatment planning system (TPS) using two (coplanar)/conventional tangential fields for a total dose of 50 Gy in 25 fractions. Analysis of 150 EPIs determined changes in the treatment fields during setup of these 25 patients. The online assessment included setup deviations in all the three directions (anteroposterior [AP], superoinferior [SI], and mediolateral [ML]) and variations in central lung distance (CLD) during the first three fractions. Results: Random errors ranged from 1 to 5 mm for the chest wall (medial and lateral) tangential treatments and 1 mm for the anterior supraclavicular nodal field. Systematic errors ranged from 2.5 to 4.5 mm in the AP direction for the tangential fields and from 2.5 to 7.5 mm in the SI and Mediolateral directions for the anterior supraclavicular nodal field. For 25 (left-sided) patients, the CLD (TPS) was 20–30 mm, CLD (EPIs) was 25–40 mm showing variations of 5–10 mm, V20 was 1.0–6.0 Gy, maximum total lung dose was 43 Gy, V30 was 2.0–4.0 Gy, maximum heart dose was 52 Gy, and maximum spine dose was 45 Gy. Conclusions: Online assessment of patient position with matching of EPIs with digitally reconstructed radiographs is a useful method in evaluation of interfraction reproducibility of tangential fields in breast irradiation, thereby improving upon the quality of treatment delivery for our patient population.
topic central lung distance
digitally reconstructed radiographs
electronic portal imaging
random errors
setup reproducibility
systematic errors/setup errors
three-dimensional computerized tomography images
url http://www.marinemedicalsociety.in/article.asp?issn=0975-3605;year=2020;volume=22;issue=1;spage=30;epage=34;aulast=Taneja
work_keys_str_mv AT sachintaneja patientsetupvariationsincomputedtomographybasedtreatmentplanningforleftsidedbreastcancerusingelectronicportalimages
AT deboleenamukherjee patientsetupvariationsincomputedtomographybasedtreatmentplanningforleftsidedbreastcancerusingelectronicportalimages
AT kirtityagi patientsetupvariationsincomputedtomographybasedtreatmentplanningforleftsidedbreastcancerusingelectronicportalimages
_version_ 1724963439297691648