Waveform Similarity Analysis: A Simple Template Comparing Approach for Detecting and Quantifying Noisy Evoked Compound Action Potentials.

Experimental electrophysiological assessment of evoked responses from regenerating nerves is challenging due to the typical complex response of events dispersed over various latencies and poor signal-to-noise ratio. Our objective was to automate the detection of compound action potential events and...

Full description

Bibliographic Details
Main Authors: Jason Robert Potas, Newton Gonçalves de Castro, Ted Maddess, Marcio Nogueira de Souza
Format: Article
Language:English
Published: Public Library of Science (PLoS) 2015-01-01
Series:PLoS ONE
Online Access:http://europepmc.org/articles/PMC4556619?pdf=render
id doaj-20dd76fdeaf249e9ac3a0e7fe533e0a6
record_format Article
spelling doaj-20dd76fdeaf249e9ac3a0e7fe533e0a62020-11-25T00:05:34ZengPublic Library of Science (PLoS)PLoS ONE1932-62032015-01-01109e013699210.1371/journal.pone.0136992Waveform Similarity Analysis: A Simple Template Comparing Approach for Detecting and Quantifying Noisy Evoked Compound Action Potentials.Jason Robert PotasNewton Gonçalves de CastroTed MaddessMarcio Nogueira de SouzaExperimental electrophysiological assessment of evoked responses from regenerating nerves is challenging due to the typical complex response of events dispersed over various latencies and poor signal-to-noise ratio. Our objective was to automate the detection of compound action potential events and derive their latencies and magnitudes using a simple cross-correlation template comparison approach. For this, we developed an algorithm called Waveform Similarity Analysis. To test the algorithm, challenging signals were generated in vivo by stimulating sural and sciatic nerves, whilst recording evoked potentials at the sciatic nerve and tibialis anterior muscle, respectively, in animals recovering from sciatic nerve transection. Our template for the algorithm was generated based on responses evoked from the intact side. We also simulated noisy signals and examined the output of the Waveform Similarity Analysis algorithm with imperfect templates. Signals were detected and quantified using Waveform Similarity Analysis, which was compared to event detection, latency and magnitude measurements of the same signals performed by a trained observer, a process we called Trained Eye Analysis. The Waveform Similarity Analysis algorithm could successfully detect and quantify simple or complex responses from nerve and muscle compound action potentials of intact or regenerated nerves. Incorrectly specifying the template outperformed Trained Eye Analysis for predicting signal amplitude, but produced consistent latency errors for the simulated signals examined. Compared to the trained eye, Waveform Similarity Analysis is automatic, objective, does not rely on the observer to identify and/or measure peaks, and can detect small clustered events even when signal-to-noise ratio is poor. Waveform Similarity Analysis provides a simple, reliable and convenient approach to quantify latencies and magnitudes of complex waveforms and therefore serves as a useful tool for studying evoked compound action potentials in neural regeneration studies.http://europepmc.org/articles/PMC4556619?pdf=render
collection DOAJ
language English
format Article
sources DOAJ
author Jason Robert Potas
Newton Gonçalves de Castro
Ted Maddess
Marcio Nogueira de Souza
spellingShingle Jason Robert Potas
Newton Gonçalves de Castro
Ted Maddess
Marcio Nogueira de Souza
Waveform Similarity Analysis: A Simple Template Comparing Approach for Detecting and Quantifying Noisy Evoked Compound Action Potentials.
PLoS ONE
author_facet Jason Robert Potas
Newton Gonçalves de Castro
Ted Maddess
Marcio Nogueira de Souza
author_sort Jason Robert Potas
title Waveform Similarity Analysis: A Simple Template Comparing Approach for Detecting and Quantifying Noisy Evoked Compound Action Potentials.
title_short Waveform Similarity Analysis: A Simple Template Comparing Approach for Detecting and Quantifying Noisy Evoked Compound Action Potentials.
title_full Waveform Similarity Analysis: A Simple Template Comparing Approach for Detecting and Quantifying Noisy Evoked Compound Action Potentials.
title_fullStr Waveform Similarity Analysis: A Simple Template Comparing Approach for Detecting and Quantifying Noisy Evoked Compound Action Potentials.
title_full_unstemmed Waveform Similarity Analysis: A Simple Template Comparing Approach for Detecting and Quantifying Noisy Evoked Compound Action Potentials.
title_sort waveform similarity analysis: a simple template comparing approach for detecting and quantifying noisy evoked compound action potentials.
publisher Public Library of Science (PLoS)
series PLoS ONE
issn 1932-6203
publishDate 2015-01-01
description Experimental electrophysiological assessment of evoked responses from regenerating nerves is challenging due to the typical complex response of events dispersed over various latencies and poor signal-to-noise ratio. Our objective was to automate the detection of compound action potential events and derive their latencies and magnitudes using a simple cross-correlation template comparison approach. For this, we developed an algorithm called Waveform Similarity Analysis. To test the algorithm, challenging signals were generated in vivo by stimulating sural and sciatic nerves, whilst recording evoked potentials at the sciatic nerve and tibialis anterior muscle, respectively, in animals recovering from sciatic nerve transection. Our template for the algorithm was generated based on responses evoked from the intact side. We also simulated noisy signals and examined the output of the Waveform Similarity Analysis algorithm with imperfect templates. Signals were detected and quantified using Waveform Similarity Analysis, which was compared to event detection, latency and magnitude measurements of the same signals performed by a trained observer, a process we called Trained Eye Analysis. The Waveform Similarity Analysis algorithm could successfully detect and quantify simple or complex responses from nerve and muscle compound action potentials of intact or regenerated nerves. Incorrectly specifying the template outperformed Trained Eye Analysis for predicting signal amplitude, but produced consistent latency errors for the simulated signals examined. Compared to the trained eye, Waveform Similarity Analysis is automatic, objective, does not rely on the observer to identify and/or measure peaks, and can detect small clustered events even when signal-to-noise ratio is poor. Waveform Similarity Analysis provides a simple, reliable and convenient approach to quantify latencies and magnitudes of complex waveforms and therefore serves as a useful tool for studying evoked compound action potentials in neural regeneration studies.
url http://europepmc.org/articles/PMC4556619?pdf=render
work_keys_str_mv AT jasonrobertpotas waveformsimilarityanalysisasimpletemplatecomparingapproachfordetectingandquantifyingnoisyevokedcompoundactionpotentials
AT newtongoncalvesdecastro waveformsimilarityanalysisasimpletemplatecomparingapproachfordetectingandquantifyingnoisyevokedcompoundactionpotentials
AT tedmaddess waveformsimilarityanalysisasimpletemplatecomparingapproachfordetectingandquantifyingnoisyevokedcompoundactionpotentials
AT marcionogueiradesouza waveformsimilarityanalysisasimpletemplatecomparingapproachfordetectingandquantifyingnoisyevokedcompoundactionpotentials
_version_ 1725424502716760064