Role of strain elastosonography, B mode and color duplex ultrasonography in differentiation between benign and malignant axillary lymph nodes

Aim and objectives: to evaluate diagnostic accuracy of combined gray scale, color Doppler and strain elastosonography in differentiation between benign and malignant axillary lymph nodes. Methodology: 50 patients with 60 enlarged axillary lymph nodes (20 male and 30 female), their ages ranged from 2...

Full description

Bibliographic Details
Main Authors: Mohammed M. Dawoud, Hanan A. Nagy, Alzahraa A. Allam
Format: Article
Language:English
Published: SpringerOpen 2018-06-01
Series:The Egyptian Journal of Radiology and Nuclear Medicine
Subjects:
Online Access:http://www.sciencedirect.com/science/article/pii/S0378603X18300470
id doaj-20927171d7d344ada5a1fa9a2f58a2ae
record_format Article
spelling doaj-20927171d7d344ada5a1fa9a2f58a2ae2020-11-25T02:14:12ZengSpringerOpenThe Egyptian Journal of Radiology and Nuclear Medicine0378-603X2018-06-0149248549110.1016/j.ejrnm.2018.02.008Role of strain elastosonography, B mode and color duplex ultrasonography in differentiation between benign and malignant axillary lymph nodesMohammed M. Dawoud0Hanan A. Nagy1Alzahraa A. Allam2Radio-diagnosis & Medical Imaging Department, Faculty of Medicine, Tanta University, EgyptRadio-diagnosis & Medical Imaging Department, Faculty of Medicine, Tanta University, EgyptInternal Medicine and Hematology, Faculty of Medicine, Tanta University, EgyptAim and objectives: to evaluate diagnostic accuracy of combined gray scale, color Doppler and strain elastosonography in differentiation between benign and malignant axillary lymph nodes. Methodology: 50 patients with 60 enlarged axillary lymph nodes (20 male and 30 female), their ages ranged from 25 to 66 years with a mean of 37.4 years. Grey scale, color-power Doppler US and strain elastography were performed for all patient. Results: absent echogenic hilum, LS/TS ratio less than 2, transverse diameter more than 7, cortical thickness more than 3 mm, high RI were the most US patterns predictive of malignancy. Suspicious lymph nodes by elastography (Scores 3 and 4) were found in 45 (75%) lymph nodes with sensitivity 88.89%, specificity 66.67%; accuracy 83.33%. The best strain ratio cutoff of 2.3 with sensitivity 87.89% and specificity 65.67%; accuracy 82.3%. Rounded shaped, loss or compressed nodal hilum and suspicious elastography score (3 & 4) were the most predictive for malignancy with sensitivity 86.67% and specificity 93.33%; accuracy 88.33%. Conclusion: combined gray scale, color Doppler US and elastography improve diagnostic accuracy of conventional ultrasound alone in differentiation between benign and malignant axillary lymph nodes with sensitivity 86.67%, and specificity 93.33%; accuracy 88.33%.http://www.sciencedirect.com/science/article/pii/S0378603X18300470Axillary lymph nodesElastography
collection DOAJ
language English
format Article
sources DOAJ
author Mohammed M. Dawoud
Hanan A. Nagy
Alzahraa A. Allam
spellingShingle Mohammed M. Dawoud
Hanan A. Nagy
Alzahraa A. Allam
Role of strain elastosonography, B mode and color duplex ultrasonography in differentiation between benign and malignant axillary lymph nodes
The Egyptian Journal of Radiology and Nuclear Medicine
Axillary lymph nodes
Elastography
author_facet Mohammed M. Dawoud
Hanan A. Nagy
Alzahraa A. Allam
author_sort Mohammed M. Dawoud
title Role of strain elastosonography, B mode and color duplex ultrasonography in differentiation between benign and malignant axillary lymph nodes
title_short Role of strain elastosonography, B mode and color duplex ultrasonography in differentiation between benign and malignant axillary lymph nodes
title_full Role of strain elastosonography, B mode and color duplex ultrasonography in differentiation between benign and malignant axillary lymph nodes
title_fullStr Role of strain elastosonography, B mode and color duplex ultrasonography in differentiation between benign and malignant axillary lymph nodes
title_full_unstemmed Role of strain elastosonography, B mode and color duplex ultrasonography in differentiation between benign and malignant axillary lymph nodes
title_sort role of strain elastosonography, b mode and color duplex ultrasonography in differentiation between benign and malignant axillary lymph nodes
publisher SpringerOpen
series The Egyptian Journal of Radiology and Nuclear Medicine
issn 0378-603X
publishDate 2018-06-01
description Aim and objectives: to evaluate diagnostic accuracy of combined gray scale, color Doppler and strain elastosonography in differentiation between benign and malignant axillary lymph nodes. Methodology: 50 patients with 60 enlarged axillary lymph nodes (20 male and 30 female), their ages ranged from 25 to 66 years with a mean of 37.4 years. Grey scale, color-power Doppler US and strain elastography were performed for all patient. Results: absent echogenic hilum, LS/TS ratio less than 2, transverse diameter more than 7, cortical thickness more than 3 mm, high RI were the most US patterns predictive of malignancy. Suspicious lymph nodes by elastography (Scores 3 and 4) were found in 45 (75%) lymph nodes with sensitivity 88.89%, specificity 66.67%; accuracy 83.33%. The best strain ratio cutoff of 2.3 with sensitivity 87.89% and specificity 65.67%; accuracy 82.3%. Rounded shaped, loss or compressed nodal hilum and suspicious elastography score (3 & 4) were the most predictive for malignancy with sensitivity 86.67% and specificity 93.33%; accuracy 88.33%. Conclusion: combined gray scale, color Doppler US and elastography improve diagnostic accuracy of conventional ultrasound alone in differentiation between benign and malignant axillary lymph nodes with sensitivity 86.67%, and specificity 93.33%; accuracy 88.33%.
topic Axillary lymph nodes
Elastography
url http://www.sciencedirect.com/science/article/pii/S0378603X18300470
work_keys_str_mv AT mohammedmdawoud roleofstrainelastosonographybmodeandcolorduplexultrasonographyindifferentiationbetweenbenignandmalignantaxillarylymphnodes
AT hanananagy roleofstrainelastosonographybmodeandcolorduplexultrasonographyindifferentiationbetweenbenignandmalignantaxillarylymphnodes
AT alzahraaaallam roleofstrainelastosonographybmodeandcolorduplexultrasonographyindifferentiationbetweenbenignandmalignantaxillarylymphnodes
_version_ 1724901181674749952