Design of a Piezoelectric Accelerometer with High Sensitivity and Low Transverse Effect

In order to meet the requirements of cable fault detection, a new structure of piezoelectric accelerometer was designed and analyzed in detail. The structure was composed of a seismic mass, two sensitive beams, and two added beams. Then, simulations including the maximum stress, natural frequency, a...

Full description

Bibliographic Details
Main Authors: Bian Tian, Hanyue Liu, Ning Yang, Yulong Zhao, Zhuangde Jiang
Format: Article
Language:English
Published: MDPI AG 2016-09-01
Series:Sensors
Subjects:
Online Access:http://www.mdpi.com/1424-8220/16/10/1587
Description
Summary:In order to meet the requirements of cable fault detection, a new structure of piezoelectric accelerometer was designed and analyzed in detail. The structure was composed of a seismic mass, two sensitive beams, and two added beams. Then, simulations including the maximum stress, natural frequency, and output voltage were carried out. Moreover, comparisons with traditional structures of piezoelectric accelerometer were made. To verify which vibration mode is the dominant one on the acceleration and the space between the mass and glass, mode analysis and deflection analysis were carried out. Fabricated on an n-type single crystal silicon wafer, the sensor chips were wire-bonged to printed circuit boards (PCBs) and simply packaged for experiments. Finally, a vibration test was conducted. The results show that the proposed piezoelectric accelerometer has high sensitivity, low resonance frequency, and low transverse effect.