The influence of description of fire curves on the thermal and reliability response of steel structure

The paper presents a proposal for the assessment of the reliability of statically determinate steel truss in the persistent and accidental (fire) design situation. The steel truss was modelled as series system from the reliability standpoint. The global Hasofer-Lind reliability index was employed, c...

Full description

Bibliographic Details
Main Authors: Kubicka Katarzyna, Radoń Urszula, Szaniec Waldemar
Format: Article
Language:English
Published: EDP Sciences 2017-01-01
Series:MATEC Web of Conferences
Online Access:https://doi.org/10.1051/matecconf/201711700095
Description
Summary:The paper presents a proposal for the assessment of the reliability of statically determinate steel truss in the persistent and accidental (fire) design situation. The steel truss was modelled as series system from the reliability standpoint. The global Hasofer-Lind reliability index was employed, computed in successive time steps for the whole structure, not for individual elements. Fire analysis was carried out according to three different time-temperature curves-standard, hydrocarbon and external. Monitoring the reliability index in the successive minutes of the fire makes it possible to estimate the probability of the structure failure, and to decide whether the required safety level is maintained.
ISSN:2261-236X