A new approach to the Danish guidelines for fire protection of combustible insulation
The tendency to use thicker layers of insulation and a wider use of combustible insulation materials is identified to pose a potential risk to fire safety of buildings. A new approach to the current Danish prescriptive code on fire protection of combustible insulation is proposed as a way to meet th...
Main Authors: | , |
---|---|
Format: | Article |
Language: | English |
Published: |
EDP Sciences
2013-11-01
|
Series: | MATEC Web of Conferences |
Online Access: | http://dx.doi.org/10.1051/matecconf/20130901001 |
id |
doaj-1f5643c2aaaf49eb9aaa4e1c23e4da09 |
---|---|
record_format |
Article |
spelling |
doaj-1f5643c2aaaf49eb9aaa4e1c23e4da092021-03-02T10:02:18ZengEDP SciencesMATEC Web of Conferences2261-236X2013-11-0190100110.1051/matecconf/20130901001A new approach to the Danish guidelines for fire protection of combustible insulationDragsted AndersBach Vestergaard AndersThe tendency to use thicker layers of insulation and a wider use of combustible insulation materials is identified to pose a potential risk to fire safety of buildings. A new approach to the current Danish prescriptive code on fire protection of combustible insulation is proposed as a way to meet the concern. The new approach uses the fire properties of the insulation material itself to point out the necessary protective measures. This is contrary to the most European countries were only a reaction to fire class of the façade construction as a whole is required. The basic principle is presented but more research is needed to complete the new approach. http://dx.doi.org/10.1051/matecconf/20130901001 |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Dragsted Anders Bach Vestergaard Anders |
spellingShingle |
Dragsted Anders Bach Vestergaard Anders A new approach to the Danish guidelines for fire protection of combustible insulation MATEC Web of Conferences |
author_facet |
Dragsted Anders Bach Vestergaard Anders |
author_sort |
Dragsted Anders |
title |
A new approach to the Danish guidelines for fire protection of combustible insulation |
title_short |
A new approach to the Danish guidelines for fire protection of combustible insulation |
title_full |
A new approach to the Danish guidelines for fire protection of combustible insulation |
title_fullStr |
A new approach to the Danish guidelines for fire protection of combustible insulation |
title_full_unstemmed |
A new approach to the Danish guidelines for fire protection of combustible insulation |
title_sort |
new approach to the danish guidelines for fire protection of combustible insulation |
publisher |
EDP Sciences |
series |
MATEC Web of Conferences |
issn |
2261-236X |
publishDate |
2013-11-01 |
description |
The tendency to use thicker layers of insulation and a wider use of combustible insulation materials is identified to pose a potential risk to fire safety of buildings. A new approach to the current Danish prescriptive code on fire protection of combustible insulation is proposed as a way to meet the concern. The new approach uses the fire properties of the insulation material itself to point out the necessary protective measures. This is contrary to the most European countries were only a reaction to fire class of the façade construction as a whole is required. The basic principle is presented but more research is needed to complete the new approach. |
url |
http://dx.doi.org/10.1051/matecconf/20130901001 |
work_keys_str_mv |
AT dragstedanders anewapproachtothedanishguidelinesforfireprotectionofcombustibleinsulation AT bachvestergaardanders anewapproachtothedanishguidelinesforfireprotectionofcombustibleinsulation AT dragstedanders newapproachtothedanishguidelinesforfireprotectionofcombustibleinsulation AT bachvestergaardanders newapproachtothedanishguidelinesforfireprotectionofcombustibleinsulation |
_version_ |
1724237828930404352 |