Model Based Control of Moisture Sorption in a Historical Interior

This paper deals with a novel scheme for microclimate control in historical exhibition rooms, inhibiting moisture sorption phenomena that are inadmissible from the preventive conservation point of view. The impact of air humidity is the most significant harmful exposure for a great deal of the cultu...

Full description

Bibliographic Details
Main Authors: P. Zítek, T. Vyhlídal
Format: Article
Language:English
Published: CTU Central Library 2005-01-01
Series:Acta Polytechnica
Subjects:
Online Access:https://ojs.cvut.cz/ojs/index.php/ap/article/view/726
id doaj-1f38d77262b247478eba19303806963a
record_format Article
spelling doaj-1f38d77262b247478eba19303806963a2020-11-24T21:17:58ZengCTU Central LibraryActa Polytechnica1210-27091805-23632005-01-01454726Model Based Control of Moisture Sorption in a Historical InteriorP. ZítekT. VyhlídalThis paper deals with a novel scheme for microclimate control in historical exhibition rooms, inhibiting moisture sorption phenomena that are inadmissible from the preventive conservation point of view. The impact of air humidity is the most significant harmful exposure for a great deal of the cultural heritage deposited in remote historical buildings. Leaving the interior temperature to run almost its spontaneous yearly cycle, the proposed non-linear model-based control protects exhibits from harmful variations in moisture content by compensating the temperature drifts with an adequate adjustment of the air humidity. Already implemented in a medieval interior since 1999, the proposed microclimate control has proved capable of permanently maintaining constant a desirable moisture content in organic or porous materials in the interior of a building. https://ojs.cvut.cz/ojs/index.php/ap/article/view/726equilibrium moisture sorptionhumidity controlnon-linear cascade control
collection DOAJ
language English
format Article
sources DOAJ
author P. Zítek
T. Vyhlídal
spellingShingle P. Zítek
T. Vyhlídal
Model Based Control of Moisture Sorption in a Historical Interior
Acta Polytechnica
equilibrium moisture sorption
humidity control
non-linear cascade control
author_facet P. Zítek
T. Vyhlídal
author_sort P. Zítek
title Model Based Control of Moisture Sorption in a Historical Interior
title_short Model Based Control of Moisture Sorption in a Historical Interior
title_full Model Based Control of Moisture Sorption in a Historical Interior
title_fullStr Model Based Control of Moisture Sorption in a Historical Interior
title_full_unstemmed Model Based Control of Moisture Sorption in a Historical Interior
title_sort model based control of moisture sorption in a historical interior
publisher CTU Central Library
series Acta Polytechnica
issn 1210-2709
1805-2363
publishDate 2005-01-01
description This paper deals with a novel scheme for microclimate control in historical exhibition rooms, inhibiting moisture sorption phenomena that are inadmissible from the preventive conservation point of view. The impact of air humidity is the most significant harmful exposure for a great deal of the cultural heritage deposited in remote historical buildings. Leaving the interior temperature to run almost its spontaneous yearly cycle, the proposed non-linear model-based control protects exhibits from harmful variations in moisture content by compensating the temperature drifts with an adequate adjustment of the air humidity. Already implemented in a medieval interior since 1999, the proposed microclimate control has proved capable of permanently maintaining constant a desirable moisture content in organic or porous materials in the interior of a building. 
topic equilibrium moisture sorption
humidity control
non-linear cascade control
url https://ojs.cvut.cz/ojs/index.php/ap/article/view/726
work_keys_str_mv AT pzitek modelbasedcontrolofmoisturesorptioninahistoricalinterior
AT tvyhlidal modelbasedcontrolofmoisturesorptioninahistoricalinterior
_version_ 1726011099170471936