Dry Blood Spots a Reliable Method for Measurement of Hepatitis B Viral Load in Resource-Limited Settings.

Hepatitis B virus (HBV) quantification is essential in the management of chronic hepatitis B, both to determine treatment eligibility and in the monitoring of treatment effect. This test, however, is rarely available in resource-limited settings due to high costs and stringent requirements for shipm...

Full description

Bibliographic Details
Main Authors: Kathrine Stene-Johansen, Nadeem Yaqoob, Joakim Overbo, Hanna Aberra, Hailemichael Desalegn, Nega Berhe, Asgeir Johannessen
Format: Article
Language:English
Published: Public Library of Science (PLoS) 2016-01-01
Series:PLoS ONE
Online Access:http://europepmc.org/articles/PMC5098817?pdf=render
id doaj-1ef40ca48c8b42fdbe3fbdfe71d6f97e
record_format Article
spelling doaj-1ef40ca48c8b42fdbe3fbdfe71d6f97e2020-11-24T20:45:38ZengPublic Library of Science (PLoS)PLoS ONE1932-62032016-01-011111e016620110.1371/journal.pone.0166201Dry Blood Spots a Reliable Method for Measurement of Hepatitis B Viral Load in Resource-Limited Settings.Kathrine Stene-JohansenNadeem YaqoobJoakim OverboHanna AberraHailemichael DesalegnNega BerheAsgeir JohannessenHepatitis B virus (HBV) quantification is essential in the management of chronic hepatitis B, both to determine treatment eligibility and in the monitoring of treatment effect. This test, however, is rarely available in resource-limited settings due to high costs and stringent requirements for shipment and storage of plasma. Dried Blood Spots (DBS) can be a convenient alternative to plasma, but its use for HBV monitoring has not been investigated under real-life conditions in Africa.The performance of DBS in HBV quantification was investigated using a modified commercial test (Abbott RealTime HBV assay). Paired DBS and plasma samples were collected from an HBV positive cohort in Addis Ababa, Ethiopia. DBS were stored at ambient temperature for 4-39 days before shipment to the laboratory.Twenty-six paired samples were selected covering the total range of quantification, from 2.14 log IU/ml to >7 log IU/ml. HBV was detected in 21 of 21 (100%) DBS from patients with a corresponding plasma viral load above 2.70 log IU/ml. The mean difference between plasma and DBS was 0.59 log IU/ml, and the correlation was strong (R2 = 0.92). In stability studies there was no significant change in DBS viral load after storage at room temperature for up to 12 weeks.This study suggests that DBS can be a feasible and reliable alternative to plasma for quantification of HBV in resource-limited settings. DBS can expand access to antiviral treatment for patients in low- and middle-income countries.http://europepmc.org/articles/PMC5098817?pdf=render
collection DOAJ
language English
format Article
sources DOAJ
author Kathrine Stene-Johansen
Nadeem Yaqoob
Joakim Overbo
Hanna Aberra
Hailemichael Desalegn
Nega Berhe
Asgeir Johannessen
spellingShingle Kathrine Stene-Johansen
Nadeem Yaqoob
Joakim Overbo
Hanna Aberra
Hailemichael Desalegn
Nega Berhe
Asgeir Johannessen
Dry Blood Spots a Reliable Method for Measurement of Hepatitis B Viral Load in Resource-Limited Settings.
PLoS ONE
author_facet Kathrine Stene-Johansen
Nadeem Yaqoob
Joakim Overbo
Hanna Aberra
Hailemichael Desalegn
Nega Berhe
Asgeir Johannessen
author_sort Kathrine Stene-Johansen
title Dry Blood Spots a Reliable Method for Measurement of Hepatitis B Viral Load in Resource-Limited Settings.
title_short Dry Blood Spots a Reliable Method for Measurement of Hepatitis B Viral Load in Resource-Limited Settings.
title_full Dry Blood Spots a Reliable Method for Measurement of Hepatitis B Viral Load in Resource-Limited Settings.
title_fullStr Dry Blood Spots a Reliable Method for Measurement of Hepatitis B Viral Load in Resource-Limited Settings.
title_full_unstemmed Dry Blood Spots a Reliable Method for Measurement of Hepatitis B Viral Load in Resource-Limited Settings.
title_sort dry blood spots a reliable method for measurement of hepatitis b viral load in resource-limited settings.
publisher Public Library of Science (PLoS)
series PLoS ONE
issn 1932-6203
publishDate 2016-01-01
description Hepatitis B virus (HBV) quantification is essential in the management of chronic hepatitis B, both to determine treatment eligibility and in the monitoring of treatment effect. This test, however, is rarely available in resource-limited settings due to high costs and stringent requirements for shipment and storage of plasma. Dried Blood Spots (DBS) can be a convenient alternative to plasma, but its use for HBV monitoring has not been investigated under real-life conditions in Africa.The performance of DBS in HBV quantification was investigated using a modified commercial test (Abbott RealTime HBV assay). Paired DBS and plasma samples were collected from an HBV positive cohort in Addis Ababa, Ethiopia. DBS were stored at ambient temperature for 4-39 days before shipment to the laboratory.Twenty-six paired samples were selected covering the total range of quantification, from 2.14 log IU/ml to >7 log IU/ml. HBV was detected in 21 of 21 (100%) DBS from patients with a corresponding plasma viral load above 2.70 log IU/ml. The mean difference between plasma and DBS was 0.59 log IU/ml, and the correlation was strong (R2 = 0.92). In stability studies there was no significant change in DBS viral load after storage at room temperature for up to 12 weeks.This study suggests that DBS can be a feasible and reliable alternative to plasma for quantification of HBV in resource-limited settings. DBS can expand access to antiviral treatment for patients in low- and middle-income countries.
url http://europepmc.org/articles/PMC5098817?pdf=render
work_keys_str_mv AT kathrinestenejohansen drybloodspotsareliablemethodformeasurementofhepatitisbviralloadinresourcelimitedsettings
AT nadeemyaqoob drybloodspotsareliablemethodformeasurementofhepatitisbviralloadinresourcelimitedsettings
AT joakimoverbo drybloodspotsareliablemethodformeasurementofhepatitisbviralloadinresourcelimitedsettings
AT hannaaberra drybloodspotsareliablemethodformeasurementofhepatitisbviralloadinresourcelimitedsettings
AT hailemichaeldesalegn drybloodspotsareliablemethodformeasurementofhepatitisbviralloadinresourcelimitedsettings
AT negaberhe drybloodspotsareliablemethodformeasurementofhepatitisbviralloadinresourcelimitedsettings
AT asgeirjohannessen drybloodspotsareliablemethodformeasurementofhepatitisbviralloadinresourcelimitedsettings
_version_ 1716814281359491072