Injecting drug use via femoral vein puncture: preliminary findings of a point-of-care ultrasound service for opioid-dependent groin injectors in treatment

<p>Abstract</p> <p>Background</p> <p>Within the UK, injecting in the femoral vein (FV), often called 'groin injecting', is a serious cause of risk and harm. This study aimed to use ultrasound scanning as a means to engage groin injectors (GIs), examine their f...

Full description

Bibliographic Details
Main Authors: Senbanjo Richard, Tipping Tracey, Hunt Neil, Strang John
Format: Article
Language:English
Published: BMC 2012-01-01
Series:Harm Reduction Journal
Subjects:
Online Access:http://www.harmreductionjournal.com/content/9/1/6
id doaj-1eed1bc370d54c3e9f31b0ff08e4dacf
record_format Article
spelling doaj-1eed1bc370d54c3e9f31b0ff08e4dacf2020-11-24T22:38:51ZengBMCHarm Reduction Journal1477-75172012-01-0191610.1186/1477-7517-9-6Injecting drug use via femoral vein puncture: preliminary findings of a point-of-care ultrasound service for opioid-dependent groin injectors in treatmentSenbanjo RichardTipping TraceyHunt NeilStrang John<p>Abstract</p> <p>Background</p> <p>Within the UK, injecting in the femoral vein (FV), often called 'groin injecting', is a serious cause of risk and harm. This study aimed to use ultrasound scanning as a means to engage groin injectors (GIs), examine their femoral injecting sites and assess their venous health, with the intention of developing improved responses.</p> <p>Methods</p> <p>Between September 2006 and March 2009, GIs attending a network of community drug treatment centres in South East England were invited to attend an ultrasound 'health-check' clinic. This paper provides a narrative account of the scanning procedure and operation of the service, with descriptive statistical analysis of GIs who attended. The analysis uses a structured, specially-developed clinical data set that incorporates a categorisation for the severity of FV damage. Case studies using ultrasound images and a link to a video are provided to illustrate the range of presentations encountered and the categorisations used for severity.</p> <p>Results</p> <p>A total of 160 groin scans (76 bilateral and 8 unilateral) were performed in 84 GIs. The majority were men (69.0%) and the mean age of the sample was 36.8 years. The mean duration of drug use and injecting drug use was 19.7 years and 13.8 years, respectively. FV damage at the injecting site in the right groin was graded as minimal in 20 patients (25%), moderate in 27 (33.8%), severe in 16 (20.0%) and very-severe in 17 (21.3%). Corresponding figures for left FV were 24 (30.0%), 22 (27.5%), 18 (22.5%) and 16 (20.0%). Wide variation was observed in the time to the development of these grades of FV damage.</p> <p>Conclusions</p> <p>Modern, portable ultrasound scanners make it possible to examine the venous health of GIs in community treatment settings. Ultrasound scanning identified extensive FV damage, much hitherto-unrecognised in this population. These findings should further alert clinicians, policy-makers and patients to the urgent need for effective harm reduction responses to GI behaviour. Images of damaged FV in this paper might prove to be a useful resource for discussions about GI risks.</p> http://www.harmreductionjournal.com/content/9/1/6Injecting drug usegroin injectingfemoral vein damageultrasonographyharm reduction
collection DOAJ
language English
format Article
sources DOAJ
author Senbanjo Richard
Tipping Tracey
Hunt Neil
Strang John
spellingShingle Senbanjo Richard
Tipping Tracey
Hunt Neil
Strang John
Injecting drug use via femoral vein puncture: preliminary findings of a point-of-care ultrasound service for opioid-dependent groin injectors in treatment
Harm Reduction Journal
Injecting drug use
groin injecting
femoral vein damage
ultrasonography
harm reduction
author_facet Senbanjo Richard
Tipping Tracey
Hunt Neil
Strang John
author_sort Senbanjo Richard
title Injecting drug use via femoral vein puncture: preliminary findings of a point-of-care ultrasound service for opioid-dependent groin injectors in treatment
title_short Injecting drug use via femoral vein puncture: preliminary findings of a point-of-care ultrasound service for opioid-dependent groin injectors in treatment
title_full Injecting drug use via femoral vein puncture: preliminary findings of a point-of-care ultrasound service for opioid-dependent groin injectors in treatment
title_fullStr Injecting drug use via femoral vein puncture: preliminary findings of a point-of-care ultrasound service for opioid-dependent groin injectors in treatment
title_full_unstemmed Injecting drug use via femoral vein puncture: preliminary findings of a point-of-care ultrasound service for opioid-dependent groin injectors in treatment
title_sort injecting drug use via femoral vein puncture: preliminary findings of a point-of-care ultrasound service for opioid-dependent groin injectors in treatment
publisher BMC
series Harm Reduction Journal
issn 1477-7517
publishDate 2012-01-01
description <p>Abstract</p> <p>Background</p> <p>Within the UK, injecting in the femoral vein (FV), often called 'groin injecting', is a serious cause of risk and harm. This study aimed to use ultrasound scanning as a means to engage groin injectors (GIs), examine their femoral injecting sites and assess their venous health, with the intention of developing improved responses.</p> <p>Methods</p> <p>Between September 2006 and March 2009, GIs attending a network of community drug treatment centres in South East England were invited to attend an ultrasound 'health-check' clinic. This paper provides a narrative account of the scanning procedure and operation of the service, with descriptive statistical analysis of GIs who attended. The analysis uses a structured, specially-developed clinical data set that incorporates a categorisation for the severity of FV damage. Case studies using ultrasound images and a link to a video are provided to illustrate the range of presentations encountered and the categorisations used for severity.</p> <p>Results</p> <p>A total of 160 groin scans (76 bilateral and 8 unilateral) were performed in 84 GIs. The majority were men (69.0%) and the mean age of the sample was 36.8 years. The mean duration of drug use and injecting drug use was 19.7 years and 13.8 years, respectively. FV damage at the injecting site in the right groin was graded as minimal in 20 patients (25%), moderate in 27 (33.8%), severe in 16 (20.0%) and very-severe in 17 (21.3%). Corresponding figures for left FV were 24 (30.0%), 22 (27.5%), 18 (22.5%) and 16 (20.0%). Wide variation was observed in the time to the development of these grades of FV damage.</p> <p>Conclusions</p> <p>Modern, portable ultrasound scanners make it possible to examine the venous health of GIs in community treatment settings. Ultrasound scanning identified extensive FV damage, much hitherto-unrecognised in this population. These findings should further alert clinicians, policy-makers and patients to the urgent need for effective harm reduction responses to GI behaviour. Images of damaged FV in this paper might prove to be a useful resource for discussions about GI risks.</p>
topic Injecting drug use
groin injecting
femoral vein damage
ultrasonography
harm reduction
url http://www.harmreductionjournal.com/content/9/1/6
work_keys_str_mv AT senbanjorichard injectingdruguseviafemoralveinpuncturepreliminaryfindingsofapointofcareultrasoundserviceforopioiddependentgroininjectorsintreatment
AT tippingtracey injectingdruguseviafemoralveinpuncturepreliminaryfindingsofapointofcareultrasoundserviceforopioiddependentgroininjectorsintreatment
AT huntneil injectingdruguseviafemoralveinpuncturepreliminaryfindingsofapointofcareultrasoundserviceforopioiddependentgroininjectorsintreatment
AT strangjohn injectingdruguseviafemoralveinpuncturepreliminaryfindingsofapointofcareultrasoundserviceforopioiddependentgroininjectorsintreatment
_version_ 1725711575040393216