Techniques of Ozone Monitoring in a Mountain Forest Region: Passive and Continuous Sampling, Vertical and Canopy Profiles

Ozone is the most harmful air pollutant for plant ecosystems in the Mediterranean and Alpine areas due to its biological and economic damage to crops and forests. In order to evaluate the relation between ozone exposure and vegetation injury under on-field conditions, suitable ozone monitoring techn...

Full description

Bibliographic Details
Main Authors: Giacomo Gerosa, Cristina Mazzali, Antonio Ballarin-Denti
Format: Article
Language:English
Published: Hindawi Limited 2001-01-01
Series:The Scientific World Journal
Online Access:http://dx.doi.org/10.1100/tsw.2001.84
id doaj-1ecec79d7d8c4555a4b2097d6708581f
record_format Article
spelling doaj-1ecec79d7d8c4555a4b2097d6708581f2020-11-24T21:26:06ZengHindawi LimitedThe Scientific World Journal1537-744X2001-01-01161262610.1100/tsw.2001.84Techniques of Ozone Monitoring in a Mountain Forest Region: Passive and Continuous Sampling, Vertical and Canopy ProfilesGiacomo Gerosa0Cristina Mazzali1Antonio Ballarin-Denti2University of Milan, Dept. of Plant Production, via Celoria 2, 20133 Milano, ItalyUniversity of Milan, Dept. of Plant Production, via Celoria 2, 20133 Milano, ItalyUniversity of Milan, Dept. of Plant Production, via Celoria 2, 20133 Milano, ItalyOzone is the most harmful air pollutant for plant ecosystems in the Mediterranean and Alpine areas due to its biological and economic damage to crops and forests. In order to evaluate the relation between ozone exposure and vegetation injury under on-field conditions, suitable ozone monitoring techniques were investi-gated. In the framework of a 5-year research project aimed at ozone risk assessment on forests, both continuous analysers and passive samplers were employed during the summer seasons (1994�1998) in different sites of a wide mountain region (80 x 40 km2) on the southern slope of the European Alps. Continuous analysers allowed the recording of ozone hourly concentration means necessary both to calculate specific exposure indexes (such as AOT, SUM, W126) and to record daily time-courses. Passive samplers, even though supplied only weekly mean concentration values, made it possible to estimate the altitude concentration gradient useful to correct the altitude dependence of ozone concentrations to be inserted into exposure indexes. In-canopy ozone profiles were also determined by placing passive samplers at different heights inside the forest canopy. Vertical ozone soundings by means of tethered balloons (kytoons) allowed the measurement of the vertical concentration gradient above the forest canopy. They also revealed ozone reservoirs aloft and were useful to explain the ozone advection dynamic in mountain slopes where ground measurement proved to be inadequate. An intercomparison between passive (PASSAM, CH) and continuous measurements highlighted the necessity to accurately standardize all the exposure operations, particularly the pre- and postexposure conservation at cold temperature to avoid dye (DPE) activity. Advantages and disadvantages from each mentioned technique are discussed.http://dx.doi.org/10.1100/tsw.2001.84
collection DOAJ
language English
format Article
sources DOAJ
author Giacomo Gerosa
Cristina Mazzali
Antonio Ballarin-Denti
spellingShingle Giacomo Gerosa
Cristina Mazzali
Antonio Ballarin-Denti
Techniques of Ozone Monitoring in a Mountain Forest Region: Passive and Continuous Sampling, Vertical and Canopy Profiles
The Scientific World Journal
author_facet Giacomo Gerosa
Cristina Mazzali
Antonio Ballarin-Denti
author_sort Giacomo Gerosa
title Techniques of Ozone Monitoring in a Mountain Forest Region: Passive and Continuous Sampling, Vertical and Canopy Profiles
title_short Techniques of Ozone Monitoring in a Mountain Forest Region: Passive and Continuous Sampling, Vertical and Canopy Profiles
title_full Techniques of Ozone Monitoring in a Mountain Forest Region: Passive and Continuous Sampling, Vertical and Canopy Profiles
title_fullStr Techniques of Ozone Monitoring in a Mountain Forest Region: Passive and Continuous Sampling, Vertical and Canopy Profiles
title_full_unstemmed Techniques of Ozone Monitoring in a Mountain Forest Region: Passive and Continuous Sampling, Vertical and Canopy Profiles
title_sort techniques of ozone monitoring in a mountain forest region: passive and continuous sampling, vertical and canopy profiles
publisher Hindawi Limited
series The Scientific World Journal
issn 1537-744X
publishDate 2001-01-01
description Ozone is the most harmful air pollutant for plant ecosystems in the Mediterranean and Alpine areas due to its biological and economic damage to crops and forests. In order to evaluate the relation between ozone exposure and vegetation injury under on-field conditions, suitable ozone monitoring techniques were investi-gated. In the framework of a 5-year research project aimed at ozone risk assessment on forests, both continuous analysers and passive samplers were employed during the summer seasons (1994�1998) in different sites of a wide mountain region (80 x 40 km2) on the southern slope of the European Alps. Continuous analysers allowed the recording of ozone hourly concentration means necessary both to calculate specific exposure indexes (such as AOT, SUM, W126) and to record daily time-courses. Passive samplers, even though supplied only weekly mean concentration values, made it possible to estimate the altitude concentration gradient useful to correct the altitude dependence of ozone concentrations to be inserted into exposure indexes. In-canopy ozone profiles were also determined by placing passive samplers at different heights inside the forest canopy. Vertical ozone soundings by means of tethered balloons (kytoons) allowed the measurement of the vertical concentration gradient above the forest canopy. They also revealed ozone reservoirs aloft and were useful to explain the ozone advection dynamic in mountain slopes where ground measurement proved to be inadequate. An intercomparison between passive (PASSAM, CH) and continuous measurements highlighted the necessity to accurately standardize all the exposure operations, particularly the pre- and postexposure conservation at cold temperature to avoid dye (DPE) activity. Advantages and disadvantages from each mentioned technique are discussed.
url http://dx.doi.org/10.1100/tsw.2001.84
work_keys_str_mv AT giacomogerosa techniquesofozonemonitoringinamountainforestregionpassiveandcontinuoussamplingverticalandcanopyprofiles
AT cristinamazzali techniquesofozonemonitoringinamountainforestregionpassiveandcontinuoussamplingverticalandcanopyprofiles
AT antonioballarindenti techniquesofozonemonitoringinamountainforestregionpassiveandcontinuoussamplingverticalandcanopyprofiles
_version_ 1725981025892302848