A Kind of Fault-Tolerant Strategy for Asynchronous Motor Vector Control Current Sensor Failure
The performance of modern motor system is more and more perfect, and the corresponding control algorithm is more and more complex, so t he inevitable various of faults will happen, when Asynchronous motor in the long running process. Its need to take certain fault-tolerant method to guarantee operat...
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
IFSA Publishing, S.L.
2013-12-01
|
Series: | Sensors & Transducers |
Subjects: | |
Online Access: | http://www.sensorsportal.com/HTML/DIGEST/december_2013/PDF_vol_160/P_1655.pdf |
id |
doaj-1e4ee0cf53d4442ba1bf44bf6744db1c |
---|---|
record_format |
Article |
spelling |
doaj-1e4ee0cf53d4442ba1bf44bf6744db1c2020-11-25T02:08:28ZengIFSA Publishing, S.L.Sensors & Transducers2306-85151726-54792013-12-0116012547555A Kind of Fault-Tolerant Strategy for Asynchronous Motor Vector Control Current Sensor FailureZhang LIWEI0Huang XIANJIN1Yang YANNAN2Xu CHEN3Liu JIE4School of Electrical Engineering, Beijing Jiaotong University, Beijing 100044, China School of Electrical Engineering, Beijing Jiaotong University, Beijing 100044, China School of Electrical Engineering, Beijing Jiaotong University, Beijing 100044, China School of Electrical Engineering, Beijing Jiaotong University, Beijing 100044, China State Key Laboratory of Automotive Simulation and Control, Jilin University, Jilin 130022, ChinaThe performance of modern motor system is more and more perfect, and the corresponding control algorithm is more and more complex, so t he inevitable various of faults will happen, when Asynchronous motor in the long running process. Its need to take certain fault-tolerant method to guarantee operators' safety, and make the asynchronous motor maintain the normal operation. The three phase current sampling of asynchronous motor vector control is very important to the motor drive system. The actual current sampled by current sensor feedback to the input, and control of motor speed and torque changes for real-time. Usually use two current sensors to sample two phase current, and the third phase current is obtained by calculation. This article will use the acquisition of DC bus current to refactoring three phase current when a current sensor failure, and adopt a certain strategy to revise the three phase current. Finally, verify the validity of the control strategy through Matlab simulation. http://www.sensorsportal.com/HTML/DIGEST/december_2013/PDF_vol_160/P_1655.pdfElectric drive systemFault-tolerant controlRefactoring phase current. |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Zhang LIWEI Huang XIANJIN Yang YANNAN Xu CHEN Liu JIE |
spellingShingle |
Zhang LIWEI Huang XIANJIN Yang YANNAN Xu CHEN Liu JIE A Kind of Fault-Tolerant Strategy for Asynchronous Motor Vector Control Current Sensor Failure Sensors & Transducers Electric drive system Fault-tolerant control Refactoring phase current. |
author_facet |
Zhang LIWEI Huang XIANJIN Yang YANNAN Xu CHEN Liu JIE |
author_sort |
Zhang LIWEI |
title |
A Kind of Fault-Tolerant Strategy for Asynchronous Motor Vector Control Current Sensor Failure |
title_short |
A Kind of Fault-Tolerant Strategy for Asynchronous Motor Vector Control Current Sensor Failure |
title_full |
A Kind of Fault-Tolerant Strategy for Asynchronous Motor Vector Control Current Sensor Failure |
title_fullStr |
A Kind of Fault-Tolerant Strategy for Asynchronous Motor Vector Control Current Sensor Failure |
title_full_unstemmed |
A Kind of Fault-Tolerant Strategy for Asynchronous Motor Vector Control Current Sensor Failure |
title_sort |
kind of fault-tolerant strategy for asynchronous motor vector control current sensor failure |
publisher |
IFSA Publishing, S.L. |
series |
Sensors & Transducers |
issn |
2306-8515 1726-5479 |
publishDate |
2013-12-01 |
description |
The performance of modern motor system is more and more perfect, and the corresponding control algorithm is more and more complex, so t he inevitable various of faults will happen, when Asynchronous motor in the long running process. Its need to take certain fault-tolerant method to guarantee operators' safety, and make the asynchronous motor maintain the normal operation. The three phase current sampling of asynchronous motor vector control is very important to the motor drive system. The actual current sampled by current sensor feedback to the input, and control of motor speed and torque changes for real-time. Usually use two current sensors to sample two phase current, and the third phase current is obtained by calculation. This article will use the acquisition of DC bus current to refactoring three phase current when a current sensor failure, and adopt a certain strategy to revise the three phase current. Finally, verify the validity of the control strategy through Matlab simulation.
|
topic |
Electric drive system Fault-tolerant control Refactoring phase current. |
url |
http://www.sensorsportal.com/HTML/DIGEST/december_2013/PDF_vol_160/P_1655.pdf |
work_keys_str_mv |
AT zhangliwei akindoffaulttolerantstrategyforasynchronousmotorvectorcontrolcurrentsensorfailure AT huangxianjin akindoffaulttolerantstrategyforasynchronousmotorvectorcontrolcurrentsensorfailure AT yangyannan akindoffaulttolerantstrategyforasynchronousmotorvectorcontrolcurrentsensorfailure AT xuchen akindoffaulttolerantstrategyforasynchronousmotorvectorcontrolcurrentsensorfailure AT liujie akindoffaulttolerantstrategyforasynchronousmotorvectorcontrolcurrentsensorfailure AT zhangliwei kindoffaulttolerantstrategyforasynchronousmotorvectorcontrolcurrentsensorfailure AT huangxianjin kindoffaulttolerantstrategyforasynchronousmotorvectorcontrolcurrentsensorfailure AT yangyannan kindoffaulttolerantstrategyforasynchronousmotorvectorcontrolcurrentsensorfailure AT xuchen kindoffaulttolerantstrategyforasynchronousmotorvectorcontrolcurrentsensorfailure AT liujie kindoffaulttolerantstrategyforasynchronousmotorvectorcontrolcurrentsensorfailure |
_version_ |
1724927272059666432 |