A Kind of Fault-Tolerant Strategy for Asynchronous Motor Vector Control Current Sensor Failure

The performance of modern motor system is more and more perfect, and the corresponding control algorithm is more and more complex, so t he inevitable various of faults will happen, when Asynchronous motor in the long running process. Its need to take certain fault-tolerant method to guarantee operat...

Full description

Bibliographic Details
Main Authors: Zhang LIWEI, Huang XIANJIN, Yang YANNAN, Xu CHEN, Liu JIE
Format: Article
Language:English
Published: IFSA Publishing, S.L. 2013-12-01
Series:Sensors & Transducers
Subjects:
Online Access:http://www.sensorsportal.com/HTML/DIGEST/december_2013/PDF_vol_160/P_1655.pdf
id doaj-1e4ee0cf53d4442ba1bf44bf6744db1c
record_format Article
spelling doaj-1e4ee0cf53d4442ba1bf44bf6744db1c2020-11-25T02:08:28ZengIFSA Publishing, S.L.Sensors & Transducers2306-85151726-54792013-12-0116012547555A Kind of Fault-Tolerant Strategy for Asynchronous Motor Vector Control Current Sensor FailureZhang LIWEI0Huang XIANJIN1Yang YANNAN2Xu CHEN3Liu JIE4School of Electrical Engineering, Beijing Jiaotong University, Beijing 100044, China School of Electrical Engineering, Beijing Jiaotong University, Beijing 100044, China School of Electrical Engineering, Beijing Jiaotong University, Beijing 100044, China School of Electrical Engineering, Beijing Jiaotong University, Beijing 100044, China State Key Laboratory of Automotive Simulation and Control, Jilin University, Jilin 130022, ChinaThe performance of modern motor system is more and more perfect, and the corresponding control algorithm is more and more complex, so t he inevitable various of faults will happen, when Asynchronous motor in the long running process. Its need to take certain fault-tolerant method to guarantee operators' safety, and make the asynchronous motor maintain the normal operation. The three phase current sampling of asynchronous motor vector control is very important to the motor drive system. The actual current sampled by current sensor feedback to the input, and control of motor speed and torque changes for real-time. Usually use two current sensors to sample two phase current, and the third phase current is obtained by calculation. This article will use the acquisition of DC bus current to refactoring three phase current when a current sensor failure, and adopt a certain strategy to revise the three phase current. Finally, verify the validity of the control strategy through Matlab simulation. http://www.sensorsportal.com/HTML/DIGEST/december_2013/PDF_vol_160/P_1655.pdfElectric drive systemFault-tolerant controlRefactoring phase current.
collection DOAJ
language English
format Article
sources DOAJ
author Zhang LIWEI
Huang XIANJIN
Yang YANNAN
Xu CHEN
Liu JIE
spellingShingle Zhang LIWEI
Huang XIANJIN
Yang YANNAN
Xu CHEN
Liu JIE
A Kind of Fault-Tolerant Strategy for Asynchronous Motor Vector Control Current Sensor Failure
Sensors & Transducers
Electric drive system
Fault-tolerant control
Refactoring phase current.
author_facet Zhang LIWEI
Huang XIANJIN
Yang YANNAN
Xu CHEN
Liu JIE
author_sort Zhang LIWEI
title A Kind of Fault-Tolerant Strategy for Asynchronous Motor Vector Control Current Sensor Failure
title_short A Kind of Fault-Tolerant Strategy for Asynchronous Motor Vector Control Current Sensor Failure
title_full A Kind of Fault-Tolerant Strategy for Asynchronous Motor Vector Control Current Sensor Failure
title_fullStr A Kind of Fault-Tolerant Strategy for Asynchronous Motor Vector Control Current Sensor Failure
title_full_unstemmed A Kind of Fault-Tolerant Strategy for Asynchronous Motor Vector Control Current Sensor Failure
title_sort kind of fault-tolerant strategy for asynchronous motor vector control current sensor failure
publisher IFSA Publishing, S.L.
series Sensors & Transducers
issn 2306-8515
1726-5479
publishDate 2013-12-01
description The performance of modern motor system is more and more perfect, and the corresponding control algorithm is more and more complex, so t he inevitable various of faults will happen, when Asynchronous motor in the long running process. Its need to take certain fault-tolerant method to guarantee operators' safety, and make the asynchronous motor maintain the normal operation. The three phase current sampling of asynchronous motor vector control is very important to the motor drive system. The actual current sampled by current sensor feedback to the input, and control of motor speed and torque changes for real-time. Usually use two current sensors to sample two phase current, and the third phase current is obtained by calculation. This article will use the acquisition of DC bus current to refactoring three phase current when a current sensor failure, and adopt a certain strategy to revise the three phase current. Finally, verify the validity of the control strategy through Matlab simulation.
topic Electric drive system
Fault-tolerant control
Refactoring phase current.
url http://www.sensorsportal.com/HTML/DIGEST/december_2013/PDF_vol_160/P_1655.pdf
work_keys_str_mv AT zhangliwei akindoffaulttolerantstrategyforasynchronousmotorvectorcontrolcurrentsensorfailure
AT huangxianjin akindoffaulttolerantstrategyforasynchronousmotorvectorcontrolcurrentsensorfailure
AT yangyannan akindoffaulttolerantstrategyforasynchronousmotorvectorcontrolcurrentsensorfailure
AT xuchen akindoffaulttolerantstrategyforasynchronousmotorvectorcontrolcurrentsensorfailure
AT liujie akindoffaulttolerantstrategyforasynchronousmotorvectorcontrolcurrentsensorfailure
AT zhangliwei kindoffaulttolerantstrategyforasynchronousmotorvectorcontrolcurrentsensorfailure
AT huangxianjin kindoffaulttolerantstrategyforasynchronousmotorvectorcontrolcurrentsensorfailure
AT yangyannan kindoffaulttolerantstrategyforasynchronousmotorvectorcontrolcurrentsensorfailure
AT xuchen kindoffaulttolerantstrategyforasynchronousmotorvectorcontrolcurrentsensorfailure
AT liujie kindoffaulttolerantstrategyforasynchronousmotorvectorcontrolcurrentsensorfailure
_version_ 1724927272059666432